A Single-Channel Telemetric Intramedullary Nail for In Vivo Measurement of Fracture Healing

被引:17
|
作者
Wilson, Darren J. [1 ]
Morgan, Robert L. [1 ]
Hesselden, Katy L. [1 ]
Dodd, James R. [1 ]
Janna, Si W. [2 ]
Fagan, Michael J.
机构
[1] Smith & Nephew, Res Ctr, York YO10 5DF, N Yorkshire, England
[2] Smith & Nephew, Memphis, TN USA
关键词
fracture healing; monitoring; implant strain; load share; intramedullary nail; femur; HIP-JOINT FORCES; SHEEP; LOADS; BONE;
D O I
10.1097/BOT.0b013e3181b01c49
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The objective of this study was to develop a single-channel telemetric intramedullary nail that measures anterior-posterior bending strains and determine whether these forces decrease sigmoidally when normalized to the ground reaction force during fracture healing. Methods: A transverse midshaft femoral osteotomy (1 mm) was stabilized using a customized TriGen intramedullary nail incorporating a strain gauge in the anterior-posterior plane. Fourteen skeletally mature sheep (2-3 years old) were treated in two pilot studies (n = 3/pilot) and a pivotal study (n = 8). Three animals were excluded as a result of welfare issues. Static strain measurements were acquired at approximately 130 Hz during leg stance. In vivo gait analysis was carried out weekly to assess ground reaction forces and biweekly x-rays to assess stability and fracture healing. Animals were euthanized 12 weeks postoperatively. Callus formation was assessed by microcomputed tomography and histomorphometry. The degree of load share between bone and the nail was determined postmortem by three-point bending. Results: A significant preload was generated during implantation, most notably during placement of the four interlocking screws and by the action of attached soft tissues. Eight animals showed evidence of bone healing by x-ray, microcomputed tomography, and histology. However, a reduction in implant load was only observed with two of the eight. The degree of load sharing observed in vivo in these animals (50%-75%) compared favorably with the in vitro observations (approximately 50%). In the nonhealing ambulating animals, nail forces did not change over time. Three-point bend tests carried out on "healed" femurs suggested that load sharing between the bone and nail could be detected more easily in the absence of soft tissues. Conclusion: No clear correlation between implant strain and fracture healing was observed using the single-channel system when subjected to one external loading regime (leg stance phase). However, ex vivo biomechanical testing demonstrated that load share changes could be detected when loads were directly applied to the bone in the absence of muscle and ligament forces. These data emphasize the need to fully characterize the complex biomechanical environment of the limb to determine the load changes resulting from fracture healing.
引用
收藏
页码:702 / 709
页数:8
相关论文
共 50 条
  • [31] Comment on the article "Auxiliary locking plate improves fracture stability and healing in intertrochanteric fractures fixated by intramedullary nail (IMN)" by Eberle et al
    Eroglu, Mehmet
    Er, Mehmet Serhan
    Altinel, Levent
    CLINICAL BIOMECHANICS, 2013, 28 (04) : 480 - 480
  • [32] Study on Symmetrical Single-Channel Magnetic Induction Measurement System for Contactless Liquid Conductivity Detection
    Ke, Li
    Pan, Hong-yu
    Du, Qiang
    INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS ENGINEERING (EEME 2014), 2014, : 1128 - 1132
  • [33] SIGNIFICANCE OF PHOSPHORESCENCE IN MEASUREMENT OF LOW ENERGY BETA ISOTOPES WITH LIQUID SCINTILLATOR AND SINGLE-CHANNEL COUNTER
    FODORCSANYI, P
    LEVAY, B
    ACTA CHIMICA ACADEMIAE SCIENTARIUM HUNGARICAE, 1966, 47 (04): : 343 - +
  • [34] SINGLE-CHANNEL MEASUREMENT FROM THE CYCLIC GMP-ACTIVATED CONDUCTANCE OF CATFISH RETINAL CONES
    HAYNES, LW
    YAU, KW
    JOURNAL OF PHYSIOLOGY-LONDON, 1990, 429 : 451 - 481
  • [35] Combining Single-Channel EEG Measurement and Verbal Fluency Test - A Groundwork for Ambulatory Diagnosis of Dementia
    Lee, Je-Eon
    Park, Jaeho
    You, Sujeong
    2017 14TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2017, : 408 - 412
  • [36] In Patients with a Tibial Fracture, Low-Intensity Pulsed Ultrasound After Intramedullary Nail Fixation Did Not Accelerate Radiographic Healing or Improve Functional Recovery
    Garner, Matthew R.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (16):
  • [37] Direct measurement of single-channel Ca2+ currents in bullfrog hair cells reveals two distinct channel subtypes
    Rodriguez-Contreras, A
    Yamoah, EN
    JOURNAL OF PHYSIOLOGY-LONDON, 2001, 534 (03): : 669 - 689
  • [38] 3-D Parallel Fiber Bragg Gratings Bending Sensor Based on Single-Channel Measurement
    Wang, Hongye
    Meng, Lingzhi
    Xia, Qi
    Yang, Shitai
    Yuan, Tingting
    Zhang, Xiaotong
    Yuan, Libo
    IEEE SENSORS JOURNAL, 2023, 23 (07) : 7599 - 7607
  • [39] Agreement between jaw-muscle activity measurement with portable single-channel electromyography and polysomnography in children
    Restrepo, Claudia
    Lobbezoo, Frank
    Castrillon, Eduardo
    Svensson, Peter
    Santamaria, Adriana
    Alvarez, Claudia
    Manrique, Ruben
    Manfredini, Daniele
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2018, 28 (01) : 33 - 42
  • [40] Localization and classification of structural damage using deep learning single-channel signal-based measurement
    Ragab, M.
    Lazhari, M.
    Nehdi, M. L.
    AUTOMATION IN CONSTRUCTION, 2022, 139