A Single-Channel Telemetric Intramedullary Nail for In Vivo Measurement of Fracture Healing

被引:17
|
作者
Wilson, Darren J. [1 ]
Morgan, Robert L. [1 ]
Hesselden, Katy L. [1 ]
Dodd, James R. [1 ]
Janna, Si W. [2 ]
Fagan, Michael J.
机构
[1] Smith & Nephew, Res Ctr, York YO10 5DF, N Yorkshire, England
[2] Smith & Nephew, Memphis, TN USA
关键词
fracture healing; monitoring; implant strain; load share; intramedullary nail; femur; HIP-JOINT FORCES; SHEEP; LOADS; BONE;
D O I
10.1097/BOT.0b013e3181b01c49
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The objective of this study was to develop a single-channel telemetric intramedullary nail that measures anterior-posterior bending strains and determine whether these forces decrease sigmoidally when normalized to the ground reaction force during fracture healing. Methods: A transverse midshaft femoral osteotomy (1 mm) was stabilized using a customized TriGen intramedullary nail incorporating a strain gauge in the anterior-posterior plane. Fourteen skeletally mature sheep (2-3 years old) were treated in two pilot studies (n = 3/pilot) and a pivotal study (n = 8). Three animals were excluded as a result of welfare issues. Static strain measurements were acquired at approximately 130 Hz during leg stance. In vivo gait analysis was carried out weekly to assess ground reaction forces and biweekly x-rays to assess stability and fracture healing. Animals were euthanized 12 weeks postoperatively. Callus formation was assessed by microcomputed tomography and histomorphometry. The degree of load share between bone and the nail was determined postmortem by three-point bending. Results: A significant preload was generated during implantation, most notably during placement of the four interlocking screws and by the action of attached soft tissues. Eight animals showed evidence of bone healing by x-ray, microcomputed tomography, and histology. However, a reduction in implant load was only observed with two of the eight. The degree of load sharing observed in vivo in these animals (50%-75%) compared favorably with the in vitro observations (approximately 50%). In the nonhealing ambulating animals, nail forces did not change over time. Three-point bend tests carried out on "healed" femurs suggested that load sharing between the bone and nail could be detected more easily in the absence of soft tissues. Conclusion: No clear correlation between implant strain and fracture healing was observed using the single-channel system when subjected to one external loading regime (leg stance phase). However, ex vivo biomechanical testing demonstrated that load share changes could be detected when loads were directly applied to the bone in the absence of muscle and ligament forces. These data emphasize the need to fully characterize the complex biomechanical environment of the limb to determine the load changes resulting from fracture healing.
引用
收藏
页码:702 / 709
页数:8
相关论文
共 50 条
  • [1] Incidence of intramedullary nail removal after femoral shaft fracture healing
    Hui, Catherine
    Jorgensen, Ian
    Buckley, Richard
    Fick, Gordon
    CANADIAN JOURNAL OF SURGERY, 2007, 50 (01) : 13 - 18
  • [2] Loads acting in an intramedullary nail during fracture healing in the human femur
    Schneider, E
    Michel, MC
    Genge, M
    Zuber, K
    Ganz, R
    Perren, SM
    JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 849 - 857
  • [3] Effect of autocontrol micromotion intramedullary interlocking nail on fracture healing: an experimental study
    许纬洲
    郭晓东
    赵炬才
    王以进
    ChineseJournalofTraumatology, 2006, (03) : 152 - 160
  • [4] Effect of autocontrol micromotion intramedullary interlocking nail on fracture healing: an experimental study
    许纬洲
    郭晓东
    赵炬才
    王以进
    中华创伤杂志(英文版), 2006, (03) : 152 - 160
  • [5] Accurate and Easy Measurement of Sliding Distance of Intramedullary Nail in Trochanteric Fracture
    Chinzei, Nobuaki
    Hiranaka, Takafumi
    Niikura, Takahiro
    Fujishiro, Takaaki
    Hayashi, Shinya
    Kanzaki, Noriyuki
    Hashimoto, Shingo
    Sakai, Yoshitada
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    CLINICS IN ORTHOPEDIC SURGERY, 2015, 7 (02) : 152 - 157
  • [6] A minimally invasive percutaneous technique of intramedullary nail insertion in an animal model of fracture healing
    Bhandari, M
    Shaughnessy, S
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2001, 121 (10) : 591 - 593
  • [7] Does obesity affect diaphyseal femoral fracture healing treated with intramedullary locking nail?
    Issace, Samuel John Jebasingam
    Singh, Rashdeep Singh Jagdeb
    Sisubalasingam, Narresh
    Tokgoz, Mehmet Ali
    Jaiman, Ashish
    Rampal, Sanjiv
    JOINT DISEASES AND RELATED SURGERY, 2023, 34 (01): : 9 - 15
  • [8] A minimally invasive percutaneous technique of intramedullary nail insertion in an animal model of fracture healing
    Mohit Bhandari
    Stephen Shaughnessy
    Archives of Orthopaedic and Trauma Surgery, 2001, 121 : 591 - 593
  • [9] CHOICE OF OPTIMAL CHANNEL WIDTH IN MEASUREMENT WITH A SINGLE-CHANNEL ANALYZER
    POTSCHWADEK, B
    ATOMPRAXIS, 1967, 13 (03): : 118 - +
  • [10] In vivo measurement of bending stiffness in fracture healing
    Reiner Hente
    Jacques Cordey
    Stephan M Perren
    BioMedical Engineering OnLine, 2