Simultaneous enantioselective separation method for thyroid hormones using liquid chromatography-tandem mass spectrometry and its applications

被引:0
|
作者
Lee, Yunhee [1 ]
Bang, Eunjung [1 ]
Lee, Wonjae [2 ]
Na, Yun-Cheol [1 ]
机构
[1] Western Seoul Ctr, Korea Basic Sci Inst, 150 Bugahyeon Ro, Seoul 03759, South Korea
[2] Chosun Univ, Coll Pharm, 309 Pilmun Dong, Gwangju 61452, South Korea
关键词
Thyroid hormone; Racemization; Enantiomer separation; Chiral stationary phase;
D O I
10.1016/j.jpha.2021.113904
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method for the simultaneous determination of chiral thyroxine and the related iodinated chiral compounds using LC-MS/MS is introduced in this study. D-Thyroid hormones (THs), which are not commercially available, were produced through the racemization reaction of the L-THs in acetic acid solution containing salicylaldehyde. The solution containing D- and L-THs after the reaction was used for optimizing the chiral separation. The D- and L-THs were well separated enantiomerically under isocratic conditions in 70 % acetonitrile containing 0.1 % formic acid on a CROWNPAK (R) CR-I (+) column, but some peaks, such as those of diiodo-D-tyrosine (D-DIT)/monoiodo-L-tyrosine, diiodoD-thyronine/diiodo-L-tyrosine and D-thyroxine/triiodo-L-thyronine, overlapped chromatographically, causing misinterpretation in impurity analysis. This was overcome by using the gradient condition providing the best chiral selectivity (a) and resolution (Rs) ranging from 1.14 to 1.37 and from 2.39 to 4.52, respectively. The linearity was above 0.999 and the detection limits ranged from 8.2 to 57.7 ng/mL by the separation method. This method was applied to identify and quantify chiral impurities in authentic standards and pharmaceuticals. As a result, D-enantiomers corresponding to the L-THs standards as well as L-DIT were commonly observed as impurities. In the stability test of DL-thyroxine under acidic conditions for identifying the distribution of chiral products, it was observed that the formation of DIT by hydrolysis increased over time. Additional products formed through esterification, including thyroxine methyl ester and diiodo-tyrosine methyl ester, were newly separated and identified using a C18 column. Conversion (ME) (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Simultaneous determination of seven sex hormones in fish products using ultra performance liquid chromatography-tandem mass spectrometry
    Zhang Aizhi
    Wang Quanlin
    Shen Jian
    Zhang Shufen
    Chen Liren
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (02) : 190 - 196
  • [22] Analysis of acrylamide in different foodstuffs using liquid chromatography-tandem mass spectrometry and gas chromatography-tandem mass spectrometry
    Hoenicke, K
    Gatermann, R
    Harder, W
    Hartig, L
    [J]. ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 207 - 215
  • [23] Development of a new liquid chromatography-tandem mass spectrometry method for the determination of hormones in bovine muscle
    Mokh, Samia
    Moussa, Fadl
    Khoury, Engie E. L.
    Nassar, Rania
    Bernabo, Nicola
    Al Iskandarani, Mohamad
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 190
  • [24] Simultaneous determination of six urinary porphyrins using liquid chromatography-tandem mass spectrometry
    Bu, W
    Myers, N
    McCarty, JD
    O'Neill, T
    Hollar, S
    Stetson, PL
    Sved, DW
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (02): : 411 - 423
  • [25] Simultaneous determination of β-blockers in human plasma using liquid chromatography-tandem mass spectrometry
    Umezawa, Hironobu
    Lee, Xiao-Pen
    Arima, Yoshiko
    Hasegawa, Chika
    Izawa, Hikaru
    Kumazawa, Takeshi
    Sato, Keizo
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 702 - 711
  • [26] Quantification and Validation of Ertapenem Using a Liquid Chromatography-Tandem Mass Spectrometry Method
    van Rijn, S. P.
    Wessels, A. M. A.
    Greijdanus, B.
    Touw, D. J.
    Alffenaar, J. W. C.
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2014, 58 (06) : 3481 - 3484
  • [27] Simultaneous Determination of Ticagrelor and Its Metabolites in Human Plasma and Urine Using Liquid Chromatography-Tandem Mass Spectrometry
    Zhong, Wanping
    Wang, Xipei
    Tang, Lan
    Mai, Liping
    Chen, Xiao-Ping
    He, Guodong
    Zheng, Zhijie
    Zhong, Shilong
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (06) : 445 - 453
  • [28] Determination of 41 hormones in cereal feeds by liquid chromatography-tandem mass spectrometry
    Zhang Yi
    Lan Fang
    Zhang Feng
    Shen Jincan
    Chu Xiaogang
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (06) : 523 - 534
  • [29] Simultaneous determination of bentazone and its metabolites in postmortem whole blood using liquid chromatography-tandem mass spectrometry
    Cho, Byungsuk
    Kim, Suncheun
    In, Sangwhan
    Choe, Sanggil
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2017, 278 : 304 - 312
  • [30] Simultaneous determination of triazolam and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    Pan, Ryh-Nan
    Lin, Chang-Ching
    Huang, Pei-Wei
    Hsiong, Cheng-Huei
    Pao, Li-Heng
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 872 (1-2): : 58 - 62