X-ray calibration of the SODART flight telescopes

被引:12
|
作者
Christensen, FE
Madsen, B
Hornstrup, A
Abdali, S
Frederiksen, P
Westergaard, NJ
Polny, J
BudtzJorgensen, C
Jonasson, P
机构
关键词
X-ray telescopes; calibration; X-ray optics; synchrotron radiation;
D O I
10.1117/12.278859
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The on- and off-axis imaging properties and effective area of the two SODART flight telescopes have been measured using the expanded beam X-ray facility at the Daresbury synchrotron. From on-axis measurements the encircled power distribution and the point spread function at three energies 6.627 keV, 8.837 keV and 11.046 KeV have been measured using a one-dimensional position sensitive detector. We found that the point spread function can be presented well by a function which is a sum of a Gaussian divided by the radius and two exponential terms where the first has a lie value dose to 2 arcmin and the other a 1/e value of ca. 15 arcmin. The data have been used to calculate the Half Power Diameter (HPD) for three different SODART focal plane detectors, the High Energy Proportional Counter (HEPC) with a Field Of View (FOV) of 65 arcmin, the Low Energy Proportional Counter (LEPC) with a FOV of 33 arcmin and the 19 element solid state detector array (SIXA) with a FOV of 18 arcmin. We found that the HPD decreases with increasing energy due to poorer figure of the outermost mirrors. The HPD falls in the range from 2.4 to 3.8 arcmin depending on energy and FOV. Data have also been obtained on the on- and off-axis effective area at all three energies and compared to that obtained from a raytracing of an ideal telescope configuration. We found that the measured on-axis effective area integrated over a FOV of 105 arcmin is ca. 65 % of the area predicted from an ideal geometry. Finally the one-dimensional detector data has been used to obtain the radial dependence of the on-axis RFD and the on-axis effective area and the data from the two-dimensional position sensitive detector has been used to obtain the azimuthal dependence of the on-axis HPD and the on-avis effective area.
引用
收藏
页码:294 / 306
页数:13
相关论文
共 50 条
  • [41] A Transmissive X-ray Polarimeter Design For Hard X-ray Focusing Telescopes
    Li, Hong
    Feng, Hua
    Ji, Jianfeng
    Deng, Zhi
    He, Li
    Zeng, Ming
    Li, Tenglin
    Liu, Yinong
    Heng, Peiyin
    Wu, Qiong
    Han, Dong
    Dong, Yongwei
    Lu, Fangjun
    Zhang, Shuangnan
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XIX, 2015, 9601
  • [42] Focal X: A test facility for X-ray telescopes
    Tock, JP
    Collette, JP
    Cucchiaro, A
    Domken, I
    Stockman, Y
    Vignelles, A
    Kletzkine, P
    THIRD INTERNATIONAL SYMPOSIUM ON ENVIRONMENTAL TESTING FOR SPACE PROGRAMMES, 1997, 408 : 163 - 168
  • [43] Lobster-eye X-ray telescopes
    Hudec, R
    Pina, L
    Innerman, A
    Svéda, L
    PROCEEDINGS OF THE 5TH INTEGRAL WORKSHOP ON THE INTEGRAL UNIVERSE, 2004, 552 : 785 - 788
  • [44] LOBSTER -: New space X-ray telescopes
    Hudec, R.
    Pina, L.
    Simon, V.
    Sveda, L.
    Inneman, A.
    Semencova, V.
    Skulinova, M.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 166 : 229 - 233
  • [45] THE HARD X-RAY TELESCOPES FOR MIRAX AND PROTOMIRAX
    Braga, J.
    D'Amico, F.
    Avila, M. C.
    Rodrigues, B. H.
    Grindlay, J. E.
    Allen, B.
    Hong, J.
    Barthelmy, S.
    Rothschild, R. R.
    XIV LATIN AMERICAN REGIONAL IAU MEETING, 2014, 44 : 123 - 123
  • [46] ALTERNATIVE DESIGNS FOR SPACE X-RAY TELESCOPES
    Hudec, R.
    Pina, L.
    Marsikova, V.
    Cerna, D.
    Inneman, A.
    Tichy, V.
    INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2014, 2014, 10563
  • [47] An X-ray calibration facility with a dynamical pencil beam for the post Astro-EII telescopes
    Maeda, Y
    Itoh, A
    Itoh, K
    Kunieda, H
    Haba, Y
    Hayakawa, A
    Iizuka, R
    Inoue, C
    Ishida, M
    Misaki, K
    Mori, H
    Shibata, R
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 734 - 741
  • [48] Simulations of X-Ray Telescopes for eROSITA and IXO
    Schmid, C.
    Martin, M.
    Wilms, J.
    Kreykenbohm, I.
    Muehlegger, M.
    Brunner, H.
    Fuermetz, M.
    Predehl, P.
    Kendziorra, E.
    Barret, D.
    X-RAY ASTRONOMY-2009: PRESENT STATUS, MULTI-WAVELENGTH APPROACH AND FUTURE PERSPECTIVES, PROCEEDINGS, 2010, 1248 : 591 - +
  • [49] ESTIMATION OF IMAGE ERROR FOR X-RAY TELESCOPES
    WOLTER, H
    OPTICA ACTA, 1971, 18 (06): : 425 - &
  • [50] An alternative optical design for X-ray telescopes
    Zocchi, Fabio E.
    Vernani, Dervis
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY III, 2007, 6688