Three phase voltage correction device using Muti-Winding Transformer

被引:0
|
作者
Bevin, K. C. [1 ]
Verma, Ashu [1 ]
Chattopadhyay, Sumit K. [1 ]
机构
[1] Indian Inst Technol, Dept Energy Sci & Engn, Delhi 110016, India
来源
2022 22ND NATIONAL POWER SYSTEMS CONFERENCE, NPSC | 2022年
关键词
Multi-winding transformer; Voltage control; unbalanced distribution system; DISTRIBUTION NETWORKS; UNBALANCE REDUCTION; ENERGY-STORAGE;
D O I
10.1109/NPSC57038.2022.10069482
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a three phase voltage correction device (TPVCD) using multi-winding transformer (MWT). The device can provide balanced 3 phase power supply of desired voltage to critical consumer equipments even when the grid voltage is varying and unbalanced. The device uses a special winding and switch arrangement to emulate MWT tap changing. The MWT tap settings are dynamically adjusted using a voltage correction scheme to obtain the desired voltage. The capability of the device is verified by simulations studies under voltage imbalance scenario due to unbalanced loads in the distribution network.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Battery Voltage Sensorless Charge Equalizer Using the Multi-Winding Transformer
    Lim, Chang-Soon
    Kim, Rae-Young
    Hyun, Dong-Seok
    2012 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2012, : 789 - 793
  • [22] A Proposal of Modular Multilevel Converter Using a Three-winding Transformer
    Tamada, Shunsuke
    Nakazawa, Yosuke
    Irokawa, Shoichi
    IEEJ JOURNAL OF INDUSTRY APPLICATIONS, 2015, 4 (05) : 611 - 618
  • [23] Features of Practical Implementation of Three Phase Transformer-Rectifier Device with Pulse of Rectified Voltage P=12
    Mytsyk, G. S.
    Zaw, Tin Aung
    2018 INTERNATIONAL URAL CONFERENCE ON GREEN ENERGY (URALCON), 2018, : 215 - 222
  • [24] Modelling and Simulation studies of Inter-winding Faults in a Three Phase Distribution Transformer using EMTDC/PSCAD
    Shruthi, B. S.
    Vittal, K. Panduranga
    2013 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2013,
  • [25] Estimation of Residual Flux in Single Phase Transformer Using Dynamic Modeling of Two Winding Single Phase Transformer
    Negara, I. Made Yulistya
    Fahmi, Daniar
    Asfani, Dimas Anton
    Hernanda, I. Gusti Ngurah Satriyadi
    Aji, Ayyub Dhimastara
    2017 INTERNATIONAL SEMINAR ON INTELLIGENT TECHNOLOGY AND ITS APPLICATIONS (ISITIA), 2017, : 154 - 160
  • [26] A Novel Three-Phase Switched Multi-Winding Power Electronic Transformer
    Gupta, Ranjan K.
    Mohapatra, Krushna K.
    Mohan, Ned
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 2956 - 2963
  • [27] Voltage and current performance of a three-phase transformer under unbalanced voltage supply
    Garcia-Rios, S.
    Barrado-Rodrigo, J. A.
    Gonzalez-Molina, F.
    Guasch-Pesquer, L.
    2018 INTERNATIONAL SYMPOSIUM ON FUNDAMENTALS OF ELECTRICAL ENGINEERING (ISFEE), 2018,
  • [28] Coil Shorting Simulation in the Windings of a Triple-Phase Three-Winding Transformer
    Novozhilov A.N.
    Kolesnikov E.N.
    Novozhilov T.A.
    Russian Electrical Engineering, 2020, 91 (12) : 737 - 741
  • [29] Trifoliate Three-Phase Contactless Power Transformer in Case of Winding-Alignment
    Matsumoto, Hirokazu
    Neba, Yasuhiko
    Iura, Hideyasu
    Tsutsumi, Daisuke
    Ishizaka, Kouichi
    Itoh, Ryozo
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (01) : 53 - 62
  • [30] Study On Transformer Winding Deformation Using Low-Voltage Impedance Diagnostic Method
    Zheng, Hanbo
    Pu, Bingjian
    Shao, Yingbiao
    Li, Yuquan
    Wang, Wei
    Xue, Wenchao
    2015 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2015, : 1947 - 1952