Non-contrast enhanced MR angiography: Physical principles

被引:112
|
作者
Wheaton, Andrew J. [1 ]
Miyazaki, Mitsue [1 ]
机构
[1] Toshiba Med Res Inst, Vernon Hills, IL 60061 USA
关键词
angiography; noncontrast; unenhanced; MRA; TIME-OF-FLIGHT; STATE FREE-PRECESSION; NEPHROGENIC SYSTEMIC FIBROSIS; FAST SPIN-ECHO; VARIABLE FLIP ANGLE; MAGNETIC-RESONANCE ANGIOGRAPHY; DISTAL LOWER-EXTREMITIES; PULSE-WAVE VELOCITY; RENAL-ARTERIES; RISK-FACTORS;
D O I
10.1002/jmri.23641
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Noncontrast-enhanced magnetic resonance angiography (NCE-MRA) methods have been demonstrated in anatomies throughout the body. Previously established NCE-MRA techniques suffered from long scan times or low sensitivity. Advances in hardware and software have made NCE-MRA scan times clinically feasible. Recent concerns over the safety of gadolinium-based contrast material combined with the expense of the material and its administration have generated a demand for NCE-MRA. In response, several new NCE-MRA methods have been developed. The physical mechanisms underlying five general classes of NCE-MRA methods (inflow effect, flow-dependency on cardiac phase, flow-encoding, spin labeling, and relaxation) are explained. The original techniques of time-of-flight (TOF) and phase contrast MRA (PC-MRA) are briefly introduced. New developments in NCE-MRA, including hybrid of opposite-contrast (HOP-MRA), four dimensional PC-MRA (4D Flow), cardiac-gated 3D fast-spin-echo, flow-sensitive dephasing (FSD), arterial spin labeling (ASL), and balanced steady-state free-precession (bSSFP) are highlighted. The primary applications, advantages, and limitations of established and emerging NCE-MRA techniques are discussed. J. Magn. Reson. Imaging 2012;36:286304. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:286 / 304
页数:19
相关论文
共 50 条
  • [21] Contrast-enhanced MR angiography
    J. H. Maki
    T. L. Chenevert
    M. R. Prince
    [J]. Abdominal Imaging, 1998, 23 : 469 - 484
  • [22] Contrast-enhanced MR angiography
    Maki, JH
    Chenevert, TL
    Prince, MR
    [J]. ABDOMINAL IMAGING, 1998, 23 (05): : 469 - 484
  • [23] Non-Contrast Enhanced Magnetic Resonance Angiography: A Modern Alternative for Arteriopaths in Renal Failure
    Chaudhuri, Arindam
    Dey, Ramita
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 56 (05) : 680 - 680
  • [24] Non-contrast enhanced, high-speed thoracic and abdominal magnetic resonance angiography
    Wielopolski, PA
    Van Geuns, RJ
    Nieman, K
    Foo, TK
    Pattynama, PM
    Krestin, GP
    [J]. RADIOLOGY, 2002, 225 : 475 - 475
  • [25] Contrast- vs. non-contrast enhanced MR data sets for characterization of perianal fistulas
    Kamonwon Cattapan
    Thitinan Chulroek
    Hamed Kordbacheh
    Dearada Wancharoenrung
    Mukesh Harisinghani
    [J]. Abdominal Radiology, 2019, 44 : 446 - 455
  • [26] Contrast- vs. non-contrast enhanced MR data sets for characterization of perianal fistulas
    Cattapan, Kamonwon
    Chulroek, Thitinan
    Kordbacheh, Hamed
    Wancharoenrung, Dearada
    Harisinghani, Mukesh
    [J]. ABDOMINAL RADIOLOGY, 2019, 44 (02) : 446 - 455
  • [27] Non-contrast versus contrast-enhanced MR in the diagnosis of spondylitis: A quantitative concordance-analysis
    Prasetyo, Marcel
    Sirath, Aldi Semanta
    Wicaksono, Krishna Pandu
    Prihartono, Joedo
    Setiawan, Stefanus Imanuel
    [J]. EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2020, 7
  • [28] Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography
    Zeilinger, Martin Georg
    Giese, Daniel
    Schmidt, Michaela
    May, Matthias Stefan
    Janka, Rolf
    Heiss, Rafael
    Ammon, Fabian
    Achenbach, Stephan
    Uder, Michael
    Treutlein, Christoph
    [J]. RADIOLOGIA MEDICA, 2024, 129 (02): : 268 - 279
  • [29] Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography
    Martin Georg Zeilinger
    Daniel Giese
    Michaela Schmidt
    Matthias Stefan May
    Rolf Janka
    Rafael Heiss
    Fabian Ammon
    Stephan Achenbach
    Michael Uder
    Christoph Treutlein
    [J]. La radiologia medica, 2024, 129 : 268 - 279
  • [30] Non-contrast enhanced silent MR angiography to evaluate hemodynamics and morphology of unruptured intracranial aneurysms: a comparative computational fluid dynamics study
    Lu, Yuzhao
    Leng, Xiaochang
    Zou, Rong
    Chen, Qi
    Li, Wenqiang
    Zhou, Xiaobing
    Tan, Song
    Huang, Xiaofei
    Ding, Cong
    Gong, Feixiang
    Xiang, Jianping
    Wang, Yang
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023, 15 (08) : 753 - 759