Methane-in-air standards measured using a 1.65 μm frequency-stabilized cavity ring-down spectrometer

被引:5
|
作者
Chu, P. M. [1 ]
Hodges, J. T. [1 ]
Rhoderick, G. C. [1 ]
Lisak, D. [1 ,2 ]
Travis, J. C. [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[2] Uniwersytet Mikolaja Kopernika, Inst Fizyki, PL-87100 Torun, Poland
关键词
cavity ring-down spectroscopy; gas analysis; quantitative absorption spectroscopy; methane standards;
D O I
10.1117/12.684931
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Frequency-stabilized cavity ring-down absorption spectrometry (FS-CRDS) with single-mode excitation using a tunable continuous-wave diode laser is being developed to help support the delivery of reference gas concentration standards. This paper describes initial efforts to compare FS-CRDS measurements with National Institute of Standards and Technology (NIST) methane-in-air standard reference materials to demonstrate the potential of this method to deliver standards-grade measurements with uncertainties of 1 % or lower. The current work demonstrates measurements with residual standard deviations of approximately 1 % for methane sample mole fractions of 50 mu mol mol(-1) and above. The results for lower mole fraction samples are poorer due to the poor signal-to-noise ratios and the higher pressures required for the measurements. The current results are potentially limited by the Voigt line shape which was used to model the data.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Frequency-stabilized cavity ring-down spectroscopy
    Long, David A.
    Cygan, Agata
    Lisak, Daniel
    Hodges, Joseph T.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [2] Frequency-stabilized cavity ring-down spectroscopy
    Long, D. A.
    Cygan, A.
    van Zee, R. D.
    Okumura, M.
    Miller, C. E.
    Lisak, D.
    Hodges, J. T.
    CHEMICAL PHYSICS LETTERS, 2012, 536 : 1 - 8
  • [3] Pound-Drever-Hall-locked, frequency-stabilized cavity ring-down spectrometer
    Cygan, A.
    Lisak, D.
    Maslowski, P.
    Bielska, K.
    Wojtewicz, S.
    Domyslawska, J.
    Trawinski, R. S.
    Ciurylo, R.
    Abe, H.
    Hodges, J. T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (06):
  • [4] Automated high-resolution frequency-stabilized cavity ring-down absorption spectrometer
    Hodges, JT
    Ciurylo, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (02): : 023112 - 1
  • [5] Frequency-stabilized cavity ring-down spectroscopy with a PDH locked laser
    Cygan, A.
    Lisak, D.
    Maslowski, P.
    Bielska, K.
    Wojtewicz, S.
    Domyslawska, J.
    Abe, H.
    Hodges, J. T.
    Trawinski, R. S.
    Ciurylo, R.
    20TH INTERNATIONAL CONFERENCE ON SPECTRAL LINE SHAPES, 2010, 1290 : 204 - +
  • [6] Frequency-stabilized cavity ring-down spectrometer for high-sensitivity measurements of water vapor concentration
    Hodges, J. T.
    Lisak, D.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 375 - 382
  • [7] Frequency-stabilized cavity ring-down spectrometer for high-sensitivity measurements of water vapor concentration
    J.T. Hodges
    D. Lisak
    Applied Physics B, 2006, 85 : 375 - 382
  • [8] Trace detection of methane using continuous wave cavity ring-down spectroscopy at 1.65 μm
    Fawcett, BL
    Parkes, AM
    Shallcross, DE
    Orr-Ewing, AJ
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2002, 4 (24) : 5960 - 5965
  • [9] Absorption line metrology by optical feedback frequency-stabilized cavity ring-down spectroscopy
    Burkart, Johannes
    Kassi, Samir
    APPLIED PHYSICS B-LASERS AND OPTICS, 2015, 119 (01): : 97 - 109
  • [10] Frequency-stabilized cavity ring-down spectroscopy measurements of carbon dioxide isotopic ratios
    Long, D. A.
    Okumura, M.
    Miller, C. E.
    Hodges, J. T.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2011, 105 (02): : 471 - 477