Automated high-resolution frequency-stabilized cavity ring-down absorption spectrometer

被引:81
|
作者
Hodges, JT
Ciurylo, R
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[2] Uniwersytet Mikolaja Kopernika, Inst Fiz, PL-87100 Torun, Poland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2005年 / 76卷 / 02期
关键词
D O I
10.1063/1.1850633
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a frequency-stabilized cavity ring-down absorption spectrometer with automated scanning capabilities. The system utilizes the comb of ring-down cavity resonances as frequency markers for spectral scans. The comb is actively stabilized with respect to a frequency-stabilized reference laser, and the continuous wave, single-mode probe laser frequency is in turn actively stabilized with respect to resonances of the ring-down cavity frequency comb. Ring-down spectra are obtained by locking the external-cavity diode laser probe to sequential cavity resonances (separated by the ring-down cavity free spectral range), and the ring-down cavity frequency comb is translated by controlled amounts using acousto-optic frequency shifting methods for fine frequency steps less than the free-spectral range. A computer-controlled method for automating frequency tuning and probe laser locking to the cavity resonances is described, and high-resolution near-infrared (vicinity of 10 712 cm(-1)) absorption spectra of water vapor are presented. A frequency resolution of approximate to1 MHz and minimum measurable line intensity of 10(-27) cm(2) cm(-1) molecule(-1) are demonstrated. (C) 2005 American Institute of Physics.
引用
收藏
页码:023112 / 1
页数:7
相关论文
共 50 条
  • [1] Frequency-stabilized single-mode cavity ring-down apparatus for high-resolution absorption spectroscopy
    Hodges, JT
    Layer, HP
    Miller, WW
    Scace, GE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (04): : 849 - 863
  • [2] Frequency-stabilized cavity ring-down spectroscopy
    Long, David A.
    Cygan, Agata
    Lisak, Daniel
    Hodges, Joseph T.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [3] Frequency-stabilized cavity ring-down spectroscopy
    Long, D. A.
    Cygan, A.
    van Zee, R. D.
    Okumura, M.
    Miller, C. E.
    Lisak, D.
    Hodges, J. T.
    CHEMICAL PHYSICS LETTERS, 2012, 536 : 1 - 8
  • [4] Pound-Drever-Hall-locked, frequency-stabilized cavity ring-down spectrometer
    Cygan, A.
    Lisak, D.
    Maslowski, P.
    Bielska, K.
    Wojtewicz, S.
    Domyslawska, J.
    Trawinski, R. S.
    Ciurylo, R.
    Abe, H.
    Hodges, J. T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (06):
  • [5] Frequency-stabilized cavity ring-down spectrometer for high-sensitivity measurements of water vapor concentration
    Hodges, J. T.
    Lisak, D.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 375 - 382
  • [6] Frequency-stabilized cavity ring-down spectrometer for high-sensitivity measurements of water vapor concentration
    J.T. Hodges
    D. Lisak
    Applied Physics B, 2006, 85 : 375 - 382
  • [7] Absorption line metrology by optical feedback frequency-stabilized cavity ring-down spectroscopy
    Burkart, Johannes
    Kassi, Samir
    APPLIED PHYSICS B-LASERS AND OPTICS, 2015, 119 (01): : 97 - 109
  • [8] Absorption line metrology by optical feedback frequency-stabilized cavity ring-down spectroscopy
    Johannes Burkart
    Samir Kassi
    Applied Physics B, 2015, 119 : 97 - 109
  • [9] Frequency-stabilized cavity ring-down spectroscopy with a PDH locked laser
    Cygan, A.
    Lisak, D.
    Maslowski, P.
    Bielska, K.
    Wojtewicz, S.
    Domyslawska, J.
    Abe, H.
    Hodges, J. T.
    Trawinski, R. S.
    Ciurylo, R.
    20TH INTERNATIONAL CONFERENCE ON SPECTRAL LINE SHAPES, 2010, 1290 : 204 - +
  • [10] Methane-in-air standards measured using a 1.65 μm frequency-stabilized cavity ring-down spectrometer
    Chu, P. M.
    Hodges, J. T.
    Rhoderick, G. C.
    Lisak, D.
    Travis, J. C.
    CHEMICAL AND BIOLOGICAL SENSORS FOR INDUSTRIAL AND ENVIRONMENTAL MONITORING II, 2006, 6378