Impact of Proximal Balloon Occlusion on the Measurement of Luminal Size and Fibrous Cap Thickness by Optical Coherence Tomography

被引:0
|
作者
Sato, Takao [1 ]
Kameyama, Tomoki [1 ]
Noto, Takahisa [2 ]
Inoue, Hiroshi [1 ]
机构
[1] Toyama Univ, Toyama 930, Japan
[2] Salseikai Toyama Hosp, Toyama, Japan
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:S923 / S923
页数:1
相关论文
共 50 条
  • [1] Measurement of the thickness of the fibrous cap by optical coherence tomography
    Kume, Teruyoshi
    Akasaka, Takashi
    Kawamoto, Takahiro
    Okura, Hiroyuki
    Watanabe, Nozomi
    Toyota, Eiji
    Neishi, Yoji
    Sukmawan, Renan
    Sadahira, Yoshito
    Yoshida, Kiyoshi
    [J]. AMERICAN HEART JOURNAL, 2006, 152 (04) : 755.e1 - 755.e4
  • [2] Fibrous Cap Thickness by Optical Coherence Tomography In Vivo
    Kini, Annapoorna S.
    Vengrenyuk, Yuliya
    Yoshimura, Takahiro
    Matsumura, Mitsuaki
    Pena, Jacobo
    Baber, Usman
    Moreno, Pedro
    Mehran, Roxana
    Maehara, Akiko
    Sharma, Samin
    Narula, Jagat
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (06) : 644 - 657
  • [3] Significance of fibrous cap thickness measured by optical coherence tomography.
    Takeda, Y
    Suzuki, T
    Tsuchikane, E
    Itoh, T
    Ehara, M
    Sato, H
    Matsubara, T
    Shigenori, I
    Katoh, O
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 142E - 142E
  • [4] In vivo, Raptured Plaque Fibrous Cap Thickness Assessed by Optical Coherence Tomography
    Kakita, Ken
    Kakuta, Tsunekazu
    Yonetsu, Taishi
    Lee, Tetsumin
    Takayama, Kai
    Takahashi, Kentaro
    Yamamoto, Ginga
    [J]. CIRCULATION, 2009, 120 (18) : S953 - S953
  • [5] Optical Coherence Tomography and Fibrous Cap Characterization
    Chamié D.
    Wang Z.
    Bezerra H.
    Rollins A.M.
    Costa M.A.
    [J]. Current Cardiovascular Imaging Reports, 2011, 4 (4) : 276 - 283
  • [6] Assessment of fibrous cap by optical coherence tomography
    Kume, T
    Akasaka, T
    Kawamoto, T
    Toyota, E
    Neishi, Y
    Sukmawan, R
    Saito, K
    [J]. CIRCULATION, 2005, 112 (17) : U679 - U679
  • [7] An Automated Computational Method for Quantification of Total Fibrous Cap Volume and Mean Fibrous Cap Thickness with Optical Coherence Tomography
    Woo, Vincent
    Chen, Zhi
    Hirai, Taishi
    Weber, Joseph R.
    Kovarnik, Tomas
    Wahle, Andreas
    Sonka, Milan
    Lopez, John J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B143 - B144
  • [8] New insights into fibrous cap thickness of vulnerable plaques assessed by optical coherence tomography
    Liu, Xianglan
    He, Wujian
    Hong, Xulin
    Li, Duanbin
    Chen, Zhezhe
    Wang, Yao
    Chen, Zhaoyang
    Luan, Yi
    Zhang, Wenbin
    [J]. BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [9] CHANGES IN FIBROUS CAP THICKNESS IN DIABETIC PATIENTS: A SERIAL OPTICAL COHERENCE TOMOGRAPHY STUDY
    Yamada, Ryotaro
    Okura, Hiroyuki
    Miyamoto, Yoshinori
    Kawamoto, Takahiro
    Neishi, Yoji
    Hayashida, Akihiro
    Tsuchiya, Tetsuo
    Nezuo, Shintaro
    Yoshida, Kiyoshi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1883 - E1883
  • [10] New insights into fibrous cap thickness of vulnerable plaques assessed by optical coherence tomography
    Xianglan Liu
    Wujian He
    Xulin Hong
    Duanbin Li
    Zhezhe Chen
    Yao Wang
    Zhaoyang Chen
    Yi Luan
    Wenbin Zhang
    [J]. BMC Cardiovascular Disorders, 22