A feasibility study of independent verification of dose calculation for Vero4DRT using a Clarkson-based algorithm

被引:0
|
作者
Yamashita, Mikiko [1 ,2 ]
Takahashi, Ryo [3 ]
Kokubo, Masaki [4 ]
Takayama, Kenji [5 ]
Tanabe, Hiroaki [1 ]
Sueoka, Masaki [1 ]
Ishii, Masao [6 ]
Tachibana, Hidenobu [7 ]
机构
[1] Kobe City Med Ctr Gen Hosp, Dept Radiol Technol, Kobe, Hyogo 6500047, Japan
[2] Inst Biomed Res & Innovat Lab, Radiat Oncol Grp, Kobe, Hyogo 6500047, Japan
[3] Japanese Fdn Canc Res, Canc Inst Hosp, Dept Radiat Oncol, Tokyo 1358550, Japan
[4] Kobe City Med Ctr Gen Hosp, Dept Radiat Oncol, Kobe, Hyogo 6500047, Japan
[5] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Med, Kyoto 6068507, Japan
[6] Kobe City Med Ctr West Hosp, Dept Radiol Technol, Kobe, Hyogo 6530013, Japan
[7] Natl Canc Ctr, Res Ctr Innovat Oncol, Particle Therapy Div, Chiba 2778577, Japan
关键词
Radiotherapy; Image-Guided; Quality Assurance; Algorithms; GUIDED RADIOTHERAPY SYSTEM;
D O I
10.1016/j.meddos.2017.12.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Dose verification for a gimbal-mounted image-guided radiotherapy system, Vero4DRT (Mitsubishi Heavy Industries Ltd., Tokyo, Japan) is usually carried out by pretreatment measurement. Independent verification calculations using Monte Carlo methods for Vero4DRT have been published. As the Clarkson method is faster and easier to use than measurement and Monte Carlo methods, we evaluated the accuracy of an independent calculation verification program and its feasibility as a secondary check for Vero4DRT. Computed tomography (CT)-based dose calculation was performed using a modified Clarkson-based algorithm. In this study, 120 patients' treatment plans were collected in our institute. The treatments were performed using conventional irradiation for lung and prostate, 3-dimensional (3D) conformal stereotactic body radiotherapy (SBRT) for the lung, and intensity-modulated radiation therapy (IMRT) for the prostate. Differences between the treatment planning system (TPS) and the Clarkson-based independent dose verification software were computed, and confidence limits (CLs, mean +/- 2 standard deviation %) for Vero4DRT were compared with the CLs for the C-arms linear accelerators in the previous study. The results of the CLs, the conventional irradiation, SBRT, and IMRT showed 2.2 +/- 3.5% (CL of the C-arms linear accelerators: 2.4 +/- 5.3%), 1.1 +/- 1.7% (-0.3 +/- 2.0%), 4.8 +/- 3.7% (5.4 +/- 5.3%), and -0.5 + 2.5% (-0.1 +/- 3.6%) differences, respectively. The dose disagreement between the TPS and CT-based independent dose verification software was less than the 5% action level of American Association of Physicists in Medicine (AAPM) Task Group 114 (TG114). The CLs for the gimbal-mounted Vero4DRT were similar to the deviations for C-arms linear accelerators. (C) 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 26 条
  • [21] Feasibility of CBCT-based proton dose calculation using a histogram-matching algorithm in proton beam therapy
    Arai, Kazuhiro
    Kadoya, Noriyuki
    Kato, Takahiro
    Endo, Hiromitsu
    Komori, Shinya
    Abe, Yoshitomo
    Nakamura, Tatsuya
    Wada, Hitoshi
    Kikuchi, Yasuhiro
    Takai, Yoshihiro
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 68 - 76
  • [22] Feasibility of 4DCBCT-based proton dose calculation: An ex vivo porcine lung phantom study
    Niepel, Katharina
    Kamp, Florian
    Kurz, Christopher
    Hansen, David
    Rit, Simon
    Neppl, Sebastian
    Hofmaier, Jan
    Bondesson, David
    Thieke, Christian
    Dinkel, Julien
    Belka, Claus
    Parodi, Katia
    Landry, Guillaume
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (03): : 249 - 261
  • [23] Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience
    Georg, Dietmar
    Stock, Markus
    Kroupa, Bernhard
    Olofsson, Jorgen
    Nyholm, Tufve
    Ahnesjo, Anders
    Karlsson, Mikael
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16): : 4981 - 4992
  • [24] Feasibility Study for Evaluation of IMRT Dose Distribution Using Geant4-Based Automated Algorithms
    Choi, H.
    Shin, W.
    Kim, J.
    Testa, M.
    Min, C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3432 - 3432
  • [25] Organ at risk dose calculation for left sided breast cancer treatments using intraoperative electron radiotherapy: A Monte Carlo-based feasibility study
    Mansourian, Ghazale
    Robatjazi, Mostafa
    Baghani, Hamid Reza
    Neshastehriz, Ali
    Mahdavi, Seied Rabi
    Koosha, Fereshteh
    APPLIED RADIATION AND ISOTOPES, 2020, 156
  • [26] Evaluation of the Effects of Dose on Lung Ventilation Calculated from 4D-CT using Deformable Image Registration An Application of a Ventilation Calculation Algorithm based on 4D-CT
    Latifi, Kujtim
    Dilling, Thomas J.
    Stevens, Craig W.
    Feygelman, Vladimir
    Moros, Eduardo G.
    Zhang, Geoffrey G.
    BIOIMAGING: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOIMAGING, 2014, : 5 - 11