Automatic detection of atrial fibrillation using stationary wavelet transform and support vector machine

被引:168
|
作者
Asgari, Shadnaz [1 ]
Mehrnia, Alireza [2 ]
Moussavi, Maryam [3 ]
机构
[1] Calif State Univ Long Beach, Dept Comp Engn & Comp Sci, Long Beach, CA 90840 USA
[2] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90095 USA
[3] Calif State Univ Long Beach, Dept Elect Engn, Long Beach, CA 90840 USA
关键词
Atrial fibrillation; Support vector machine; Wavelet transform; Cardiac arrhythmia; Log-energy entropy; ROC curve analysis; RISK; PREVALENCE; RHYTHM; MANAGEMENT; DIAGNOSIS; ALGORITHM; ACCURACY; STROKE; IMPACT; ECG;
D O I
10.1016/j.compbiomed.2015.03.005
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia, and a major public health burden associated with significant morbidity and mortality. Automatic detection of AF could substantially help in early diagnosis, management and consequently prevention of the complications associated with chronic AE In this paper, we propose a novel method for automatic AF detection. Method: Stationary wavelet transform and support vector machine have been employed to detect AF episodes. The proposed method eliminates the need for P-peak or R-Peak detection (a pre-processing step required by many existing algorithms), and hence its performance (sensitivity, specificity) does not depend on the performance of beat detection. The proposed method has been compared with those of the existing methods in terms of various measures including performance, transition time (detection delay associated with transitioning from a non-AF to AF episode), and computation time (using MIT-BIH Atrial Fibrillation database). Results: Results of a stratified 2-fold cross-validation reveals that the area under the Receiver Operative Characteristics (ROC) curve of the proposed method is 99.5%. Moreover, the method maintains its high accuracy regardless of the choice of the parameters' values and even for data segments as short as 10 s. Using the optimal values of the parameters, the method achieves sensitivity and specificity of 97.0% and 97.1%, respectively. Discussion: The proposed AF detection method has high sensitivity and specificity, and holds several interesting properties which make it a suitable choice for practical applications. (c) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:132 / 142
页数:11
相关论文
共 50 条
  • [1] Atrial Fibrillation Detection Using Stationary Wavelet Transform Analysis
    Weng, Binwei
    Wang, John J.
    Michaud, Francis
    Blanco-Velasco, Manuel
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1128 - +
  • [2] Automatic Arrhythmia Detection Using Support Vector Machine Based on Discrete Wavelet Transform
    Hamed, Ibrahim
    Owis, Mohamed I.
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (01) : 204 - 209
  • [3] Atrial Fibrillation Detection Using Support Vector Machine
    Nuryani, Nuryani
    Harjito, Bambang
    Yahya, Iwan
    Lestari, Anik
    [J]. PROCEEDING JOINT INTERNATIONAL CONFERENCE ON ELECTRIC VEHICULAR TECHNOLOGY AND INDUSTRIAL, MECHANICAL, ELECTRICAL, AND CHEMICAL ENGINEERING (ICEVT & IMECE), 2015, : 215 - 218
  • [4] Atrial Fibrillation Detection Using Stationary Wavelet Transform and Deep Learning
    Xia, Yong
    Wulan, Naren
    Wang, Kuanquan
    Zhang, Henggui
    [J]. 2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [5] Fall Detection using Lifting Wavelet Transform and Support Vector Machine
    Liang, Hanghan
    Usaha, Wipawee
    [J]. PROCEEDINGS OF THE 2017 FEDERATED CONFERENCE ON COMPUTER SCIENCE AND INFORMATION SYSTEMS (FEDCSIS), 2017, : 877 - 883
  • [6] Harmonic detection in distribution systems using wavelet transform and support vector machine
    Tuntisak, S.
    Premrudeepreechacharn, S.
    [J]. 2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1540 - 1545
  • [7] Fast detection of Atrial Fibrillation using wavelet transform
    Bakucz, Peter
    Willems, Stephan
    Hoffmann, Boris
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 81 - 84
  • [8] HIF Detection using Wavelet Transform, Travelling Wave and Support Vector Machine
    Bhongade, Sandeep
    Golhani, Supriya
    [J]. 2016 INTERNATIONAL CONFERENCE ON ELECTRICAL POWER AND ENERGY SYSTEMS (ICEPES), 2016, : 151 - 156
  • [9] High accuracy of automatic detection of atrial fibrillation using wavelet transform of heart rate intervals
    Duverney, D
    Gaspoz, JM
    Pichot, V
    Roche, F
    Brion, R
    Antoniadis, A
    Barthélémy, JC
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (04): : 457 - 462
  • [10] High accuracy of automatic detection of atrial fibrillation using wavelet transform of heart rate intervals
    Barthelemy, JC
    Duverney, D
    Pichot, V
    Roche, F
    Gaspoz, JM
    Antoniadis, A
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 : 219 - 219