Statistical determination of whole-body average SARs in a 2 GHz whole-body exposure system for unrestrained pregnant and newborn rats

被引:4
|
作者
Wang, Jianqing [1 ]
Wake, Kanako [2 ]
Kawai, Hiroki [2 ]
Watanabe, Soichi [2 ]
Fujiwara, Osamu [1 ]
机构
[1] Nagoya Inst Technol, Grad Sch Engn, Dept Comp Sci & Engn, Nagoya, Aichi 4668555, Japan
[2] Natl Inst Informat & Commun Technol, Tokyo 1848795, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 01期
关键词
ELECTROMAGNETIC-FIELD; SETUPS;
D O I
10.1088/0031-9155/57/1/143
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A 2 GHz whole-body exposure to rats over a multigeneration has been conducted as part of bio-effect research in Japan. In this study, the rats moved freely in the cage inside the exposure system. From observation of the activity of rats in the cage, we found that the rats do not stay in each position with uniform possibility. In order to determine the specific absorption rate (SAR) during the entire exposure period with high accuracy, we present a new approach to statistically determine the SAR level in an exposure system. First, we divided the rat cage in the exposure system into several small areas, and derived the fraction of time the rats spent in each small area based on the classification of the documentary photos of rat activity. Then, using the fraction of time spent in each small area as a weighting factor, we calculated the statistical characteristics of the whole-body average SAR for pregnant rats and young rats during the entire exposure period. As a result, this approach gave the statistical distribution as well as the corresponding mean value, median value and mode value for the whole-body SAR so that we can reasonably clarify the relationship between the exposure level and possible biological effect.
引用
收藏
页码:143 / 154
页数:12
相关论文
共 50 条
  • [21] WHOLE-BODY VIBRATION EXPOSURE AND THE HUMAN SPINE
    WASSERMAN, DE
    [J]. SOUND AND VIBRATION, 1995, 29 (04): : 5 - 5
  • [22] DESIGN AND OPERATION OF A WHOLE-BODY DYNAMIC INHALATION EXPOSURE SYSTEM
    YADAV, PC
    PATEL, TS
    JAYPAUL, N
    DEWAN, A
    KASHYAP, SK
    [J]. JOURNAL OF ENVIRONMENTAL BIOLOGY, 1994, 15 (01): : 7 - 14
  • [23] EVALUATION OF EXPOSURE TO WHOLE-BODY VIBRATION BY DOSIMETRY
    MALCHAIRE, J
    LEVIE, F
    RENS, G
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1982, 25 (04): : 373 - 380
  • [24] URINARY KALLIKREIN IN WHOLE-BODY IRRADIATED RATS
    DANCEWICZ, AM
    KUBICKA, T
    [J]. NUKLEONIKA, 1987, 32 (4-6) : 165 - 174
  • [25] REVERSIBLE WHOLE-BODY DEEP HYPOTHERMIA IN RATS
    SHCHERBAKOV, PV
    TERPUKHOV, VI
    KHOKHLOV, AV
    [J]. BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1989, 107 (05) : 617 - 619
  • [26] WHOLE-BODY SCANNER MARK 2
    ANGER, HO
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1966, 7 (05) : 331 - &
  • [27] Assessment of low level whole-body soman vapor exposure in rats
    Genovese, Raymond F.
    Benton, Bernard J.
    Johnson, Christina C.
    Jakubowski, E. Michael
    [J]. NEUROTOXICOLOGY AND TERATOLOGY, 2009, 31 (02) : 110 - 118
  • [28] Design and performance of a system for blood collection of rats under whole-body inhalation exposure
    Take, Makoto
    Ohnishi, Makoto
    Nagano, Kasuke
    Yamamoto, Seigo
    Fukushima, Shoji
    [J]. JOURNAL OF TOXICOLOGICAL SCIENCES, 2009, 34 (02): : 221 - 226
  • [29] An efficient RF exposure system with precise whole-body average SAR determination for in vivo animal studies at 900 MHz
    Balzano, Q
    Chou, CK
    Cicchetti, R
    Faraone, A
    Tay, RYS
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2000, 48 (11) : 2040 - 2049
  • [30] Measuring Respiratory Function in Mice Using Unrestrained Whole-body Plethysmography
    Lim, Rebecca
    Zavou, Marcus J.
    Milton, Phillipa-Louise
    Chan, Siow Teng
    Tan, Jean L.
    Dickinson, Hayley
    Murphy, Sean V.
    Jenkin, Graham
    Wallace, Euan M.
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (90):