Diagnostic test accuracy for detecting Schistosoma japonicum and S. mekongi in humans: A systematic review and meta-analysis

被引:14
|
作者
Rahman, Md. Obaidur [1 ,2 ]
Sassa, Miho [2 ,3 ]
Parvin, Natasha [4 ]
Islam, Md. Rashedul [2 ,5 ]
Yajima, Aya [6 ]
Ota, Erika [1 ]
机构
[1] St Lukes Int Univ, Grad Sch Nursing Sci, Dept Global Hlth Nursing, Tokyo, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Global Hlth Policy, Tokyo, Japan
[3] Nagasaki Univ, Inst Trop Med NEKKEN, Dept Parasitol, Nagasaki, Japan
[4] Hajee Mohammad Danesh Sci & Technol Univ, Dept Accounting & Informat Syst, Dinajpur, Bangladesh
[5] Natl Canc Ctr, Div Prevent, Ctr Publ Hlth Sci, Tokyo, Japan
[6] World Hlth Org, Div Progammes Dis Control, Malaria & Neglected Trop Dis Unit, Western Pacific Reg Off, Geneva, Switzerland
来源
PLOS NEGLECTED TROPICAL DISEASES | 2021年 / 15卷 / 03期
关键词
STOOL EXAMINATION; FIELD-EVALUATION; PHILIPPINES; CHINA; ASSAY; PREVALENCE; ELISA;
D O I
10.1371/journal.pntd.0009244
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Author summary Schistosomiasis remains a serious public health problem worldwide. Accurate diagnostic tests play a key role in control of schistosomiasis, especially in Asia where the prevalence and intensity of infection is low. As stool examination techniques, particularly the Kato-Katz technique has shown low sensitivity for the detection of light-intensity infections, highly sensitive diagnostics are urgently required to monitor prevalence of infection in low transmission settings. The purpose of this review was to assess and synthesize the performance of diagnostic tests for detecting schistosomiasis in people living in endemic areas in Asia. A comprehensive search, without any limit of language, date or types of publication, were performed for both- multiple electronic databases and other resources to identify the eligible studies. Robust analytical approaches such as diagnostic meta-analysis, HSROC curve, and diagnostic odds ratio, were used to provide more diagnostic accuracy of index tests. We assessed performance of three diagnostic tests (ELISA, IHA, and PCR) for detecting infection with S. japonicum using stool examination as a reference standard. In these meta-analyses, IHA showed the highest detection accuracy, followed by ELISA. We could not perform meta-analysis for S. mekongi due to insufficient number of studies. Background Most of national schistosomiasis elimination programmes in Asia are relying on stool examination, particularly Kato Katz stool examination technique for regular transmission monitoring. However, the Kato-Katz technique has shown low sensitivity for the detection of light-intensity infections, and therefore highly sensitive diagnostic tools are urgently required to monitor prevalence of infection in low transmission settings. The objective of this systematic review was to evaluate and synthesize the performance of diagnostic tests for detecting Schistosoma japonicum and S. mekongi infection in people living in endemic areas. Methodology/Principal findings We comprehensively searched these nine electronic databases and other resources until July 2019, with no language or publication limits: PubMed, EMBASE, MEDLINE, Web of Science, BIOSIS Citation Index, HTA, CINAHL PLUS, The Cochrane Library, and PsycINFO. We included original studies that assessed diagnostic performance using antibody, antigen, and molecular tests with stool examination test as a reference standard. Two reviewers independently extracted a standard set of data and assessed study quality. We estimated the pooled estimates of sensitivity and specificity for each index test. We used diagnostic odds ratio to determine the overall accuracy and hierarchical summary receiver operating characteristics (HSROC) curve to assess the index tests performance. Fifteen studies (S. japonicum [n = 13] and S. mekongi [n = 2]) testing 15,303 participants were included in the review. Five studies reported performance of enzyme-linked immunosorbent assay (ELISA), seven studies reported indirect hemagglutination assay (IHA), and four studies reported polymerase chain reaction (PCR) for detecting S. japonicum. The pooled sensitivity and specificity were 0.93 (95% CI: 0.84-0.98) and 0.40 (95% CI: 0.29-0.53) for ELISA, 0.97 (95% CI: 0.90-0.99) and 0.66 (95% CI: 0.58-0.73) for IHA, and 0.89 (95% CI: 0.71-0.96) and 0.49 (95% CI: 0.29-0.69) for PCR respectively. A global summary indicated the best performance for IHA, closely followed by ELISA. We were unable to perform meta-analysis for S. mekongi due to insufficient number of studies. Conclusions/Significance IHA showed the highest detection accuracy for S. japonicum. Further studies are needed to determine the suitable diagnostic methods to verify the absence of transmission of S. mekongi and also to compare detection accuracy against more sensitive reference standards such as PCR.
引用
下载
收藏
页数:18
相关论文
共 50 条
  • [21] A systematic review with meta-analysis of the diagnostic test accuracy of pedicle screw electrical stimulation
    Fonseca, Pedro
    Goethel, Marcio
    Vilas-Boas, Joao Paulo
    Gutierres, Manuel
    Correia, Miguel Velhote
    EUROPEAN SPINE JOURNAL, 2022, 31 (07) : 1599 - 1610
  • [22] Blood biomarkers for sarcopenia: A systematic review and meta-analysis of diagnostic test accuracy studies
    Lian, Rongna
    Liu, Qianqian
    Jiang, Gengchen
    Zhang, Xiangyu
    Tang, Huiyu
    Lu, Jing
    Yang, Ming
    AGEING RESEARCH REVIEWS, 2024, 93
  • [23] The diagnostic test accuracy of ultrasound for the detection of lateral epicondylitis: A systematic review and meta-analysis
    Latham, S. K.
    Smith, T. O.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (03) : 281 - 286
  • [24] Machine learning for the prediction of sepsis: a systematic review and meta-analysis of diagnostic test accuracy
    Fleuren, Lucas M.
    Klausch, Thomas L. T.
    Zwager, Charlotte L.
    Schoonmade, Linda J.
    Guo, Tingjie
    Roggeveen, Luca F.
    Swart, Eleonora L.
    Girbes, Armand R. J.
    Thoral, Patrick
    Ercole, Ari
    Hoogendoorn, Mark
    Elbers, Paul W. G.
    INTENSIVE CARE MEDICINE, 2020, 46 (03) : 383 - 400
  • [25] Artificial intelligence in digital pathology: a systematic review and meta-analysis of diagnostic test accuracy
    Mcgenity, Clare
    Clarke, Emily L.
    Jennings, Charlotte
    Matthews, Gillian
    Cartlidge, Caroline
    Freduah-Agyemang, Henschel
    Stocken, Deborah D.
    Treanor, Darren
    NPJ DIGITAL MEDICINE, 2024, 7 (01)
  • [26] A systematic review with meta-analysis of the diagnostic test accuracy of pedicle screw electrical stimulation
    Pedro Fonseca
    Márcio Goethel
    João Paulo Vilas-Boas
    Manuel Gutierres
    Miguel Velhote Correia
    European Spine Journal, 2022, 31 : 1599 - 1610
  • [27] The Delirium Observation Screening Scale: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy
    Park, Jinkyung
    Jeong, Eunhye
    Lee, Juneyoung
    CLINICAL NURSING RESEARCH, 2021, 30 (04) : 464 - 473
  • [28] Diagnostic test accuracy of adenosine deaminase for tuberculous meningitis: A systematic review and meta-analysis
    Pormohammad, Ali
    Riahi, Seyed-Mohammad
    Nasiri, Mohammad Javad
    Fallah, Fatemeh
    Aghazadeh, Mohammad
    Doustdar, Farahnoosh
    Pouriran, Ramin
    JOURNAL OF INFECTION, 2017, 74 (06) : 545 - 554
  • [29] DIAGNOSTIC TEST ACCURACY OF THE 4AT FOR DELIRIUM DETECTION: SYSTEMATIC REVIEW AND META-ANALYSIS
    Tieges, Z.
    MacLullich, A. M. J.
    Anand, A.
    Cassaroni, M.
    O'Connor, M.
    Ryan, D.
    Saller, T.
    Arora, R.
    Chang, Y.
    Agarwal, K.
    Taffet, G.
    Quinn, T.
    Shenkin, S.
    Galvin, R.
    AGE AND AGEING, 2021, 50
  • [30] Successful Publication of Systematic Review and Meta-Analysis of Studies Evaluating Diagnostic Test Accuracy
    Suh, Chong Hyun
    Park, Seong Ho
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (01) : 5 - 6