Changes in mitral valve geometry after percutaneous valve repair with the MitraClip® System

被引:5
|
作者
Trasca, Livia [1 ,2 ,3 ]
Sanchis, Laura [1 ,2 ]
Regueiro, Ander [1 ,2 ]
Freixa, Xavier [1 ,2 ]
Vinereanu, Dragos [4 ]
Sitges, Marta [1 ,2 ,3 ]
机构
[1] Univ Barcelona, Hosp Clin Barcelona, Cardiovasc Inst, Villarroel 170, Barcelona 08036, Spain
[2] Generalitat Catalunya, CERCA Programme, Inst Invest Biomed August Pi I Sunyer IDIBAPS, Barcelona, Spain
[3] Inst Salud Carlos III, Ctr Invest Biomed Red Enfermedades Cardiovasc CIB, CB16-11-00354, Madrid, Spain
[4] Carol Davila Univ Med & Pharm, Bucharest, Romania
来源
关键词
Annulus; Geometry; Tenting area; Interventional; MitraClip (R); REGURGITATION; SOCIETY;
D O I
10.1007/s10554-020-02137-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to assess the anatomical changes of the mitral valve apparatus after percutaneous repair with the MitraClip (R) system. We included consecutive patients who underwent MitraClip (R) implantation in our center. Patients were assessed by 2- and 3-dimensional transesophageal echocardiography, acquired before and immediately after MitraClip (R) implantation. Off-line images analysis was performed to assess mitral annular diameters (antero-posterior and inter-commisural), area and circumference. Mitral tenting distance, area and volume were evaluated for functional mitral regurgitation. Patients had a 2-dimensional transthoracic echocardiography at follow-up (8 months). 38 patients with successful results (residual mitral regurgitation grade <= II) were included. The anteroposterior annulus diameter (ADP) decreased (from 35 +/- 5 to 28 +/- 5 mm, p < 0.001) with smaller decreases in the annular area and circumference and in the inter-commissural diameter. Annular ellipticity improved. The reduction in APD and tenting distance was sustained at follow-up. Successful percutaneous mitral valve repair with the MitraClip (R) system induces a stable change in mitral valve geometry mainly at the ADP, suggesting a significant annuloplasty that contributes to the reduction of mitral regurgitation.
引用
收藏
页码:1577 / 1585
页数:9
相关论文
共 50 条
  • [21] MitraClip:a novel percutaneous approach to mitral valve repair
    Hasan JILAIHAWI
    Asma HUSSAINI
    Saibal KAR
    [J]. Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2011, 12 (08) : 633 - 637
  • [22] Percutaneous Mitral Heart Valve Repair-MitraClip
    Doshi, Jay V.
    Agrawal, Sahil
    Garg, Jalaj
    Paudel, Rajiv
    Palaniswamy, Chandrasekar
    Doshi, Tina V.
    Gotsis, William
    Frishman, William H.
    [J]. CARDIOLOGY IN REVIEW, 2014, 22 (06) : 289 - 296
  • [23] MitraClip: a novel percutaneous approach to mitral valve repair
    Jilaihawi, Hasan
    Hussaini, Asma
    Kar, Saibal
    [J]. JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2011, 12 (08): : 633 - 637
  • [24] MitraClip: a novel percutaneous approach to mitral valve repair
    Hasan Jilaihawi
    Asma Hussaini
    Saibal Kar
    [J]. Journal of Zhejiang University SCIENCE B, 2011, 12 : 633 - 637
  • [25] MitraClip:a novel percutaneous approach to mitral valve repair
    Hasan JILAIHAWI
    Asma HUSSAINI
    Saibal KAR
    [J]. Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2011, (08) : 633 - 637
  • [26] Quality Of Life Changes In High Risk Patients after Percutaneous Mitral Valve Repair with Mitraclip
    Taramasso, Maurizio
    Denti, Paolo
    Cioni, Micaela
    Buzzatti, Nicola
    Colombo, Antonio
    Alfieri, Ottavio
    Maisano, Francesco
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B213 - B213
  • [27] Percutaneous Mitral Valve Repair With Mitraclip® System in a Patient With Acute Mitral Regurgitation After Myocardial Infarction
    Rodriguez-Santamarta, Miguel
    Estevez-Loureiro, Rodrigo
    Gualis, Javier
    Alonso, David
    Perez de Prado, Armando
    Fernandez-Vazquez, Felipe
    [J]. REVISTA ESPANOLA DE CARDIOLOGIA, 2015, 68 (03): : 259 - 261
  • [28] Severe mitral regurgitation: mortality and morbidity predictors after percutaneous mitral valve repair with the mitraClip system
    Santos, R.
    Infante-Oliveira, E.
    Carrilho-Ferreira, P.
    Nobre-Menezes, M.
    Francisco, A. R.
    Rigueira, J.
    Agostinho, J. R.
    Aguiar-Ricardo, I.
    Nunes-Ferreira, A.
    Rodrigues, T.
    Cunha, N.
    Antonio, P.
    Morais, P. S.
    Pinto, F. J.
    Canas Da Silva, P.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 : 454 - 454
  • [29] Percutaneous Mitral Valve Repair with MitraClip: Patient and Valve Selection for Optimal Outcome
    Inderbitzin, Devdas T.
    Taramasso, Maurizio
    Nietlispach, Fabian
    Maisano, Francesco
    [J]. CURRENT CARDIOLOGY REPORTS, 2016, 18 (12)
  • [30] The MitraClip transcatheter mitral valve repair system
    Grasso, Carmelo
    Baldus, Stephan
    [J]. EUROINTERVENTION, 2015, 11 : W45 - W46