Changes in mitral valve geometry after percutaneous valve repair with the MitraClip® System

被引:5
|
作者
Trasca, Livia [1 ,2 ,3 ]
Sanchis, Laura [1 ,2 ]
Regueiro, Ander [1 ,2 ]
Freixa, Xavier [1 ,2 ]
Vinereanu, Dragos [4 ]
Sitges, Marta [1 ,2 ,3 ]
机构
[1] Univ Barcelona, Hosp Clin Barcelona, Cardiovasc Inst, Villarroel 170, Barcelona 08036, Spain
[2] Generalitat Catalunya, CERCA Programme, Inst Invest Biomed August Pi I Sunyer IDIBAPS, Barcelona, Spain
[3] Inst Salud Carlos III, Ctr Invest Biomed Red Enfermedades Cardiovasc CIB, CB16-11-00354, Madrid, Spain
[4] Carol Davila Univ Med & Pharm, Bucharest, Romania
来源
关键词
Annulus; Geometry; Tenting area; Interventional; MitraClip (R); REGURGITATION; SOCIETY;
D O I
10.1007/s10554-020-02137-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to assess the anatomical changes of the mitral valve apparatus after percutaneous repair with the MitraClip (R) system. We included consecutive patients who underwent MitraClip (R) implantation in our center. Patients were assessed by 2- and 3-dimensional transesophageal echocardiography, acquired before and immediately after MitraClip (R) implantation. Off-line images analysis was performed to assess mitral annular diameters (antero-posterior and inter-commisural), area and circumference. Mitral tenting distance, area and volume were evaluated for functional mitral regurgitation. Patients had a 2-dimensional transthoracic echocardiography at follow-up (8 months). 38 patients with successful results (residual mitral regurgitation grade <= II) were included. The anteroposterior annulus diameter (ADP) decreased (from 35 +/- 5 to 28 +/- 5 mm, p < 0.001) with smaller decreases in the annular area and circumference and in the inter-commissural diameter. Annular ellipticity improved. The reduction in APD and tenting distance was sustained at follow-up. Successful percutaneous mitral valve repair with the MitraClip (R) system induces a stable change in mitral valve geometry mainly at the ADP, suggesting a significant annuloplasty that contributes to the reduction of mitral regurgitation.
引用
收藏
页码:1577 / 1585
页数:9
相关论文
共 50 条
  • [1] Changes in mitral valve geometry after percutaneous valve repair with the MitraClip® System
    Livia Trasca
    Laura Sanchis
    Ander Regueiro
    Xavier Freixa
    Dragos Vinereanu
    Marta Sitges
    [J]. The International Journal of Cardiovascular Imaging, 2021, 37 : 1577 - 1585
  • [2] Changes in dynamic mitral valve geometry during percutaneous edge–edge mitral valve repair with the MitraClip system
    Thilo Noack
    Philipp Kiefer
    Linda Mallon
    Philipp Lurz
    Carmine Bevilacqua
    Joergen Banusch
    Fabian Emrich
    David M. Holzhey
    Mani Vannan
    Holger Thiele
    Friedrich-Wilhelm Mohr
    Michael Andrew Borger
    Joerg Ender
    Joerg Seeburger
    [J]. Journal of Echocardiography, 2019, 17 : 84 - 94
  • [3] Changes in dynamic mitral valve geometry during percutaneous edge-edge mitral valve repair with the MitraClip system
    Noack, Thilo
    Kiefer, Philipp
    Mallon, Linda
    Lurz, Philipp
    Bevilacqua, Carmine
    Banusch, Joergen
    Emrich, Fabian
    Holzhey, David M.
    Vannan, Mani
    Thiele, Holger
    Mohr, Friedrich-Wilhelm
    Borger, Michael Andrew
    Ender, Joerg
    Seeburger, Joerg
    [J]. JOURNAL OF ECHOCARDIOGRAPHY, 2019, 17 (02) : 84 - 94
  • [4] Percutaneous mitral valve repair with the mitraclip® system
    Paranskaya, Liliya
    D'Ancona, Giuseppe
    Bozdag-Turan, Ilkay
    Akin, Ibrahim
    Kische, Stephan
    Turan, Goekmen R.
    Divchev, Dimitar
    Rehders, Tim
    Westphal, Bernd
    Schubert, Jochen
    Nienaber, Christoph A.
    Ince, Hueseyin
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (07) : 1224 - 1231
  • [5] Changes in serum biomarker profiles after percutaneous mitral valve repair with the MitraClip system
    Yoon, Ji-Na
    Frangieh, Antonio H.
    Attinger-Toller, Adrian
    Gruner, Christiane
    Tanner, Felix C.
    Taramasso, Maurizio
    Corti, Roberto
    Luscher, Thomas F.
    Ruschitzka, Frank
    Bettex, Dominique
    Maisano, Francesco
    Gaemperli, Oliver
    [J]. CARDIOLOGY JOURNAL, 2016, 23 (04) : 384 - 392
  • [6] Acute changes in mitral valve geometry after percutaneous valve repair with MitraClip XTR by three-dimensional echocardiography
    Tusa, Maurizio B.
    Barletta, Marta
    Rubbio, Antonio Popolo
    Travaglio, Nicole
    Saffioti, Silvia
    Granata, Giuseppina
    Mantovani, Valentina
    Stefanini, Elisa
    Corciu, Anca, I
    Testa, Luca
    Bedogni, Francesco
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2021, 38 (11): : 1913 - 1923
  • [7] Late Surgical Mitral Valve Repair after Percutaneous Repair with the MitraClip® System
    Rogers, Jason H.
    Yeo, Khung Keong
    Carroll, John D.
    Cleveland, Joseph
    Reece, T. Brett
    Gillinov, A. Marc
    Rodriguez, Leonardo
    Whitlow, Patrick
    Woo, Y. Joseph
    Herrmann, Howard C.
    Young, J. Nilas
    [J]. JOURNAL OF CARDIAC SURGERY, 2009, 24 (06) : 677 - 681
  • [8] Percutaneous mitral valve repair with MitraClip
    Cilingiroglu, Mehmet
    Salinger, Michael
    [J]. TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2012, 40 (02): : 174 - 180
  • [9] Percutaneous Transhepatic Mitral Valve Repair With the MitraClip System
    de Brito, Fabio S., Jr.
    Nasser, Felipe
    Gobbo, Rodrigo
    Lemos, Pedro
    Vieira, Marcelo
    Fischer, Claudio
    Mariani, Jose, Jr.
    Galastri, Francisco L.
    Franken, Marcelo
    Martins, Jose Renato M.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (14) : E109 - E111
  • [10] Mehanisms of mitral regurgitation after percutaneous mitral valve repair with the MitraClip
    Ikenaga, Hiroki
    Makar, Moody
    Rader, Florian
    Siegel, Robert J.
    Kar, Saibal
    Makkar, Raj R.
    Shiota, Takahiro
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (10) : 1131 - 1142