Fracture toughness of bone at the microscale

被引:16
|
作者
Aldegaither, Nouf [1 ,2 ]
Sernicola, Giorgio [1 ]
Mesgarnejad, Ataollah [3 ]
Karma, Alain [3 ]
Balint, Daniel [4 ]
Wang, Jianglong [4 ]
Saiz, Eduardo [1 ]
Shefelbine, Sandra J. [5 ,6 ]
Porter, Alexandra E. [1 ]
Giuliani, Finn [1 ]
机构
[1] Imperial Coll London, Dept Mat Sci & Engn, London SW7 2AZ, England
[2] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Sci & Hlth Profess, Riyadh, Saudi Arabia
[3] Northeastern Univ, Dept Phys, Ctr Interdisciplinary Res Complex Syst, Boston, MA 02115 USA
[4] Imperial Coll London, Dept Mech Engn, London SW7 2AZ, England
[5] Northeastern Univ, Dept Mech & Ind Engn, Boston, MA 02115 USA
[6] Northeastern Univ, Dept Bioengn, Boston, MA 02115 USA
基金
英国惠康基金;
关键词
Bone; Micro scale; Fracture energy; Fracture toughness; Double cantilever beam; Fibrils; Anisotropy;
D O I
10.1016/j.actbio.2020.12.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bone's hierarchical arrangement of collagen and mineral generates a confluence of toughening mechanisms acting at every length scale from the molecular to the macroscopic level. Molecular defects, disease, and age alter bone structure at different levels and diminish its fracture resistance. However, the inability to isolate and quantify the influence of specific features hampers our understanding and the development of new therapies. Here, we combine in situ micromechanical testing, transmission electron microscopy and phase-field modelling to quantify intrinsic deformation and toughening at the fibrillar level and unveil the critical role of fibril orientation on crack deflection. At this level dry bone is highly anisotropic, with fracture energies ranging between 5 and 30 J/m2 depending on the direction of crack propagation. These values are lower than previously calculated for dehydrated samples from large-scale tests. However, they still suggest a significant amount of energy dissipation. This approach provides a new tool to uncouple and quantify, from the bottom up, the roles played by the structural features and constituents of bone on fracture and how can they be affected by different pathologies. The methodology can be extended to support the rational development of new structural composites. Statement of significance The effects of disease and age on the fracture resistance of bone have severe implications on the quality of life. These diseases can affect the molecular and nanoscale structure and organisation of bone (known as its quality) but we do not know whether these changes make the tissue more susceptible to fracture. We have developed a time-resolved mechanical test that measures the fracture toughness of bone at the nanoscale. We show that the fracture resistance at these length scales is small but significant. It is also highly anisotropic, and the crack path is related directly to the local organisation of the collagen fibrils. Understanding the contribution of ultrastructure to fracture toughness is important to predict and thus prevent bone fractures. (c) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:475 / 483
页数:9
相关论文
共 50 条
  • [41] Fracture Toughness Evaluation of Cortical Bone Preserved by Different Methods
    Kuninori, Masahiro
    Kikugawa, Hisao
    Asaka, Takashi
    Kasuya, Hirakazu
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2008, 72 (09) : 679 - 685
  • [42] Orthogonal cutting of cortical bone: Temperature elevation and fracture toughness
    Feldmann, Arne
    Ganser, Philipp
    Nolte, Lutz
    Zysset, Philippe
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2017, 118 : 1 - 11
  • [43] Interfacial fracture toughness of synthetic bone-cement interface
    Department of Mechanical and Design Engineering, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth PO1 3DJ, United Kingdom
    Key Eng Mat, 2006, (251-256):
  • [44] Interfacial fracture toughness of synthetic bone-cement interface
    Tong, J
    FRACTURE OF MATERIALS: MOVING FORWARDS, 2006, 312 : 251 - 256
  • [45] The influence of bone morphology on fracture toughness of the human femur and tibia
    Yeni, YN
    Brown, CU
    Wang, Z
    Norman, TL
    BONE, 1997, 21 (05) : 453 - 459
  • [46] Interfacial fracture toughness between bovine cortical bone and cements
    Lucksanasombool, P
    Higgs, WAJ
    Higgs, RJED
    Swain, MV
    BIOMATERIALS, 2003, 24 (07) : 1159 - 1166
  • [47] Orientation and loading condition dependence of fracture toughness in cortical bone
    Feng, ZD
    Rho, J
    Han, S
    Ziv, I
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2000, 11 (01): : 41 - 46
  • [48] Fracture toughness and crack resistance curves of acrylic bone cements
    Ziegler, Tobias
    Jaeger, Raimund
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (05) : 1961 - 1971
  • [49] Fracture toughness of steel-fiber-reinforced bone cement
    Kotha, SP
    Li, C
    Schmid, SR
    Mason, JJ
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 70A (03) : 514 - 521
  • [50] A critical evaluation of cortical bone fracture toughness testing methods
    Dapaah, Daniel
    Willett, Thomas
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 134