Calculation of whole-body organic dose in brain tumor treatment by boron neutron capture therapy

被引:0
|
作者
Matsumoto, T [1 ]
Uchiyama, T [1 ]
机构
[1] Musashi Inst Technol, Atom Energy Res Lab, Kawasaki, Kanagawa 215, Japan
关键词
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Calculation of whole-body organic dose was carried out using Monte Carlo code MCNP for a brain tumor patient in boron neutron capture therapy. The ICRU phantom model was used for the calculation. A maximum dose of 2 Gy was calculated in the head and other organ dose except an eye (0.4 Gy) were much smaller than their tolerance dose when irradiation of thermal neutron fluence of 5x10(12) ncm(-2) corresponding to the physical dose of 12 Gy for the tumor containing a B-10 concentration of 30 ppm.
引用
下载
收藏
页码:411 / 414
页数:4
相关论文
共 50 条
  • [21] DOSE PRESCRIPTION IN BORON NEUTRON-CAPTURE THERAPY
    GUPTA, N
    GAHBAUER, RA
    BLUE, TE
    WAMBERSIE, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1157 - 1166
  • [22] DOSE BRACKETING IN BORON NEUTRON-CAPTURE THERAPY
    GAHBAUER, R
    KANELLITSAS, C
    BLUE, T
    WANG, C
    CLENDENON, N
    FAIRCHILD, R
    LASTER, B
    MCGREGOR, J
    GOODMAN, J
    STRAHLENTHERAPIE UND ONKOLOGIE, 1989, 165 (2-3): : 229 - 230
  • [23] Boron neutron capture therapy for malignant brain tumors
    Miyatake, Shin-Ichi
    Wanibuchi, Masahiko
    Hu, Naonori
    Ono, Koji
    JOURNAL OF NEURO-ONCOLOGY, 2020, 149 (01) : 1 - 11
  • [24] Boron neutron capture therapy for malignant brain tumors
    Shin-Ichi Miyatake
    Masahiko Wanibuchi
    Naonori Hu
    Koji Ono
    Journal of Neuro-Oncology, 2020, 149 : 1 - 11
  • [25] Prospects in Boron Neutron Capture Therapy of Brain Tumors
    Byvaltsev, Vadim
    Kanygin, Vladimir
    Belykh, Eugeny
    Taskaev, Sergey
    WORLD NEUROSURGERY, 2012, 78 (1-2)
  • [26] Boron Neutron Capture Therapy for Malignant Brain Tumors
    Miyatake, Shin-Ichi
    Kawabata, Shinji
    Hiramatsu, Ryo
    Kuroiwa, Toshihiko
    Suzuki, Minoru
    Kondo, Natsuko
    Ono, Koji
    NEUROLOGIA MEDICO-CHIRURGICA, 2016, 56 (07) : 361 - 371
  • [27] Depth dose evaluation for prostate cancer treatment using boron neutron capture therapy
    Davood Mirzaei
    Hashem Miri-Hakimabad
    Laleh Rafat-Motavalli
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 1095 - 1101
  • [28] Depth dose evaluation for prostate cancer treatment using boron neutron capture therapy
    Mirzaei, Davood
    Miri-Hakimabad, Hashem
    Rafat-Motavalli, Laleh
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 302 (03) : 1095 - 1101
  • [29] The Photon-Isoeffective Dose in Boron Neutron Capture Therapy
    Gonzalez, Sara J.
    Santa Cruz, Gustavo A.
    RADIATION RESEARCH, 2012, 178 (06) : 609 - 621
  • [30] Microdosimetric analysis of absorbed dose in boron neutron capture therapy
    Kota, C
    Maughan, RL
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 555 - 558