Effects of remote monitoring of cardiac implantable electronic devices after stroke or transient ischemic attack

被引:7
|
作者
De Simone, Vincenzo [1 ]
Zanotto, Gabriele [1 ]
Guarise, Paola [1 ]
Venturato, Anna [1 ]
Cassinadri, Elena [1 ]
Bassi, Martina [1 ]
Bozzolin, Matteo [1 ]
Tondelli, Silvia [1 ]
Giacopelli, Daniele [2 ]
Morando, Giorgio [1 ]
机构
[1] Osped Mater Salutis, Cardiol, Legnago, VR, Italy
[2] Biotronik Italia, Clin Res, Vimodrone, MI, Italy
关键词
cardiac implantable electronic devices; pacemaker; remote monitoring; stroke; telemonitoring; transient ischemic attack; RANDOMIZED-TRIAL; EARLY RISK; FOLLOW-UP; DEFIBRILLATOR; TIME;
D O I
10.2459/JCM.0000000000000822
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac implantable electronic device (CIED) recipients who experienced an ischemic cerebral event may particularly benefit from continuous remote monitoring. We aimed to assess the effect of remote monitoring on the occurrence of 1-year serious adverse events in CIED recipients after ischemic stroke or transient ischemic attack (TIA). Methods Patients were eligible if they suffered a TIA/stroke. Study endpoints were all-cause mortality, all-cause hospitalization, and TIA/stroke recurrence. Patients were retrospectively divided according to the presence of remote monitoring for CIED follow-up. Results From January 2011 to December 2017, 71 CIED recipients were hospitalized in our institution for TIA/stroke: pacemaker (76%), cardiac resynchronization therapy device (17%), or implantable cardioverter defibrillator (7%). Among them, 26 (37%) were remotely monitored (RM-ON), whereas 45 (63%) were followed with conventional in-hospital visits (RM-OFF). No significant differences were found in baseline characteristics between groups. The all-cause mortality and hospitalization rates were significantly lower in the RM-ON group [2.2; 95% confidence interval (CI) 0.8-4.8, and 5.8; 95% CI 3.3-9.4 per 100 patient-months] as compared with the RM-OFF group (8.1; 95% CI 5.2-11.9, and 9.7; 95% CI 6.5-13.9 per 100 patient-months). Despite a similar incidence of new diagnosis of atrial fibrillation, the median time from the arrhythmic episode to the physician evaluation was dramatically lower in the RM-ON as compared with the RM-OFF group [2 (1-3) vs. 78 (64-92) days; P=0.002]. Conclusion We found that remote monitoring as compared with conventional in-hospital visits may contribute to a better outcome in CIED recipients who had suffered from an ischemic cerebral event.
引用
收藏
页码:551 / 556
页数:6
相关论文
共 50 条
  • [21] Remote monitoring of cardiovascular implantable electronic devices
    Sticherling, Christian
    Kuehne, Michael
    Schaer, Beat
    Altmann, David
    Osswald, Stefan
    SWISS MEDICAL WEEKLY, 2009, 139 (41-42) : 596 - 601
  • [22] Patient satisfaction with remote monitoring of cardiac implantable electronic devices: the Valiosa questionnaire
    Ruiz Diaz, Miguel A.
    Egea Garcia, Marta
    Munoz Aguilera, Roberto
    Vinolas Prat, Xavier
    Silvestre Garcia, Jorge
    Alvarez Orozco, Maria
    Martinez Ferrer, Jose
    BMC HEALTH SERVICES RESEARCH, 2020, 20 (01)
  • [23] Patient satisfaction with remote monitoring of cardiac implantable electronic devices: the Valiosa questionnaire
    Miguel A. Ruiz Díaz
    Marta Egea García
    Roberto Muñoz Aguilera
    Xavier Viñolas Prat
    Jorge Silvestre García
    María Álvarez Orozco
    José Martínez Ferrer
    BMC Health Services Research, 20
  • [24] Remote Monitoring for Follow-up of Patients with Cardiac Implantable Electronic Devices
    Ricci, Renato Pietro
    Morichelli, Loredana
    Varma, Niraj
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2014, 3 (02) : 123 - 128
  • [25] Optimising remote monitoring for cardiac implantable electronic devices: a UK Delphi consensus
    Ahmad, Shumaila
    Straw, Sam
    Gierula, John
    Roberts, Eleri
    Collinson, Jason
    Swift, Matthew
    Monkhouse, Chris
    Broadhurst, Lucy
    Allan, Annabel
    Jamil, Haqeel A.
    Dixon, Anne
    Black, Paula
    Pinnell, Ian
    Law, Hannah
    Archer, Natalie
    Ahmed, Fozia
    Paton, Maria F.
    HEART, 2024,
  • [26] Remote monitoring of cardiac implantable electronic devices: from data to clinical actions
    Imberti, Jacopo F.
    Vitolo, Marco
    Boriani, Giuseppe
    ACTA CARDIOLOGICA, 2023, 78 (06) : 745 - 747
  • [27] Pioglitazone after Ischemic Stroke or Transient Ischemic Attack
    Kernan, W. N.
    Viscoli, C. M.
    Furie, K. L.
    Young, L. H.
    Inzucchi, S. E.
    Gorman, M.
    Guarino, P. D.
    Lovejoy, A. M.
    Peduzzi, P. N.
    Conwit, R.
    Brass, L. M.
    Schwartz, G. G.
    Adams, H. P., Jr.
    Berger, L.
    Carolei, A.
    Clark, W.
    Coull, B.
    Ford, G. A.
    Kleindorfer, D.
    O'Leary, J. R.
    Parsons, M. W.
    Ringleb, P.
    Sen, S.
    Spence, J. D.
    Tanne, D.
    Wang, D.
    Winder, T. R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (14): : 1321 - 1331
  • [28] Pioglitazone after Ischemic Stroke or Transient Ischemic Attack
    Hu, Kejia
    Xu, Wendong
    Williams, Ziv
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (07): : 703 - 704
  • [29] The increased risk of stroke/transient ischemic attack in women with a cardiac implantable electronic device is not associated with a higher atrial fibrillation burden
    Boriani, Giuseppe
    Lip, Gregory Y. H.
    Ricci, Renato Pietro
    Proclemer, Alessandro
    Landolina, Maurizio
    Lunati, Maurizio
    Padeletti, Luigi
    Zanotto, Gabriele
    Molon, Giulio
    Biffi, Mauro
    Rordorf, Roberto
    Quartieri, Fabio
    Gasparini, Maurizio
    EUROPACE, 2017, 19 (11): : 1767 - 1775
  • [30] Prevalence of ischemic stroke in patients with chagas disease using cardiac implantable electronic devices
    Lima Freitas, E.
    Sampaio, E. S.
    Oliveira, M. M. C.
    Albuquerque, G. S. B.
    Guimaraes, M. S. S.
    Pinheiro, J. O.
    Magalhaes, L. P.
    Oliveira, L. H.
    Silva, R. S. F.
    Hora, T. R.
    Mello, J. N.
    Barretto, L. E. S.
    Aras, R.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1147 - 1148