Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope®

被引:0
|
作者
Jones, Philip M. [1 ]
Turkstra, Timothy P. [1 ]
Armstrong, Kevin P. [1 ]
Armstrong, Paidrig M. [1 ]
Cherry, Richard A. [1 ]
Hoogstra, Jason [1 ]
Harle, Christopher C. [1 ]
机构
[1] Univ Western Ontario, Dept Anesthesia & Perioperat Med, London, England
关键词
D O I
10.1007/BF03021895
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: The GlideScope (R) videolaryngoscope usually provides excellent glottic visualization, but directing an endotracheal tube (ETT) through the vocal cords is sometimes difficult. The goal of the study was to determine which of two ETT angles (60 degrees vs 90 degrees) and cambers (forward vs reverse) was better, as determined by time to intubation (TTI). Methods: Two hundred patients requiring orotracheal intubation for elective surgery were randomly allocated to one of four groups: A) 90 degrees angle, forward camber; B) 90 degrees angle, reverse camber; C) 60 degrees angle, forward camber; D) 60 degrees angle, reverse camber. Time to intubation was assessed by a blinded observer. Operators were blinded until the point of intubation. A visual analogue scale (VAS) assessed the ease of intubation. The number of intubation attempts, number of failures, glottic grades, and use of external laryngeal manipulation were recorded. Results: The angle of the ETT had an impact on TTI but camber did not. The 90 degrees angle demonstrated a 13% faster 171 than the 60 degrees angle (47.1 +/- 21.2 sec vs 54.4 +/- 28.2 sec, P = 0.042), and it resulted in easier intubation (VAS 16.4 +/- 14.2 mm vs 27.3 +/- 23.5 mm, P = 0.0001). The overall incidence of a grade 1 or 2 Cormack-Lehane glottic view was 99%. Conclusions: In a heterogeneous group of operators and patients intubated with the GlideScope (R), a 90 degrees ETT angle provided the best result and should be the initial configuration. The camber of the ETT does not affect the time to intubation.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 50 条
  • [41] Performance of the GlideRite® Rigid Stylet and malleable stylet for tracheal intubation by novices using the GlideScope® videolaryngoscope
    Fu S. Xue
    Xu Liao
    Jian H. Liu
    Yu J. Yuan
    Qiang Wang
    [J]. Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2011, 58 : 660 - 661
  • [42] INFLUENCE OF GLIDESCOPE ASSISTED ENDOTRACHEAL INTUBATION ON INTRAOCULAR PRESSURE
    Ahmadi, N.
    Zahoor, A.
    Motowa, S.
    Riad, W.
    [J]. ANESTHESIA AND ANALGESIA, 2014, 118 : S17 - S17
  • [43] Performance of the GlideRite® Rigid Stylet and malleable stylet for tracheal intubation by novices using the GlideScope® videolaryngoscope
    Xue, Fu S.
    Liao, Xu
    Liu, Jian H.
    Yuan, Yu J.
    Wang, Qiang
    [J]. CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2011, 58 (07): : 660 - 660
  • [44] Does the use of a semirigid stylet increase the efficacy of endotracheal intubation when using an ETView tube?
    Adamczyk, Piotr
    Czyzewski, Lukasz
    Smereka, Jacek
    Szarpak, Lukasz
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (09): : 1908 - 1909
  • [45] LIGHTED STYLET AND ENDOTRACHEAL INTUBATION 2. - REPLY
    FOX, DJ
    RASTRELLI, AJ
    [J]. ANESTHESIOLOGY, 1987, 66 (06) : 852 - 852
  • [46] A randomized comparison of the GlideRite® Rigid Stylet to a malleable stylet for orotracheal intubation by novices using the GlideScope®
    Jones, Philip M.
    Loh, Francis L. C.
    Youssef, Hesham N.
    Turkstra, Timothy P.
    [J]. CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2011, 58 (03): : 256 - 261
  • [47] The Effect of Stylet Choice on the Success Rate of Intubation Using the GlideScope Video Laryngoscope in the Emergency Department
    Sakles, John C.
    Kalin, Leah
    [J]. ACADEMIC EMERGENCY MEDICINE, 2012, 19 (02) : 235 - 238
  • [48] The usefulness of endotracheal tube twisting in facilitating tube delivery to glottis opening during GlideScope intubation in infants: randomized trial
    Jeong Jin Min
    Eun Jung Oh
    Young Hee Shin
    Eunjin Kwon
    Ji Seon Jeong
    [J]. Scientific Reports, 10
  • [49] GlideScope-assisted endotracheal tube exchange
    Hirabayashi, Yoshihiro
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (05) : 777 - 777
  • [50] The usefulness of endotracheal tube twisting in facilitating tube delivery to glottis opening during GlideScope intubation in infants: randomized trial
    Min, Jeong Jin
    Oh, Eun Jung
    Shin, Young Hee
    Kwon, Eunjin
    Jeong, Ji Seon
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)