摘要
Purpose: The GlideScope (R) videolaryngoscope usually provides excellent glottic visualization, but directing an endotracheal tube (ETT) through the vocal cords is sometimes difficult. The goal of the study was to determine which of two ETT angles (60 degrees vs 90 degrees) and cambers (forward vs reverse) was better, as determined by time to intubation (TTI). Methods: Two hundred patients requiring orotracheal intubation for elective surgery were randomly allocated to one of four groups: A) 90 degrees angle, forward camber; B) 90 degrees angle, reverse camber; C) 60 degrees angle, forward camber; D) 60 degrees angle, reverse camber. Time to intubation was assessed by a blinded observer. Operators were blinded until the point of intubation. A visual analogue scale (VAS) assessed the ease of intubation. The number of intubation attempts, number of failures, glottic grades, and use of external laryngeal manipulation were recorded. Results: The angle of the ETT had an impact on TTI but camber did not. The 90 degrees angle demonstrated a 13% faster 171 than the 60 degrees angle (47.1 +/- 21.2 sec vs 54.4 +/- 28.2 sec, P = 0.042), and it resulted in easier intubation (VAS 16.4 +/- 14.2 mm vs 27.3 +/- 23.5 mm, P = 0.0001). The overall incidence of a grade 1 or 2 Cormack-Lehane glottic view was 99%. Conclusions: In a heterogeneous group of operators and patients intubated with the GlideScope (R), a 90 degrees ETT angle provided the best result and should be the initial configuration. The camber of the ETT does not affect the time to intubation.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 50 条
  • [1] Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope®Effet de l’angulation du mandrin et de la cambrure de la sonde endotrachéale sur le temps requis pour l’intubation avec le GlideScope®
    Philip M. Jones
    Timothy P. Turkstra
    Kevin P. Armstrong
    Paidrig M. Armstrong
    Richard A. Cherry
    Jason Hoogstra
    Christopher C. Harle
    [J]. Canadian Journal of Anesthesia, 2007, 54 (1): : 21 - 27
  • [2] Stylet angulation for routine endotracheal intubation with McGrath videolaryngoscope
    Lee, Jiyoung
    Kim, Jong Yeop
    Kang, Se Yoon
    Kwak, Hyun Jeong
    Lee, Dongchul
    Lee, Sook Young
    [J]. MEDICINE, 2017, 96 (07)
  • [3] Tracheal intubation using the GlideScope® with a combined curved pipe stylet, and endotracheal tube introducer
    Musa Muallem
    Anis Baraka
    [J]. Canadian Journal of Anesthesia, 2007, 54 : 77 - 78
  • [4] Tracheal intubation using the GlideScope® with a combined curved pipe stylet, and endotracheal tube introducer
    Muallem, Musa
    Baraka, Anis
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (01): : 77 - 78
  • [5] Stylet angulation of 70 degrees reduces the time to intubation with the GlideScope®: A prospective randomised trial
    Lee, Yong-Cheol
    Lee, Jiwon
    Son, Je-Do
    Lee, Jae-Yoon
    Kim, Hyun-Chang
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (04) : 1428 - 1438
  • [6] Using a Glidescope for intubation with a double lumen endotracheal tube
    Ada A. Hernandez
    David H. Wong pharmd
    [J]. Canadian Journal of Anaesthesia, 2005, 52 : 658 - 659
  • [7] Facilitating GlideScope intubation with the straight end of an endotracheal tube introducer
    O'Mahony, Christopher J.
    Pagano, Parwane P.
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2013, 25 (07) : 603 - 604
  • [8] Using a Glidescope for intubation witb a double lumen endotracheal tube
    Hernandez, AA
    Wong, DH
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (06): : 658 - 659
  • [9] Use of the Endoflex® endotracheal tube as a stylet-free alternative in Glidescope intubations
    Darren Phua
    Chin Foong Wang
    Chee Seng Yoong
    [J]. Canadian Journal of Anesthesia, 2008, 55 : 473 - 474
  • [10] Angled or curved stylet for intubation with the GlideScope®?
    Dupanovic, Mirsad
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (06): : 487 - 488