A feasibility study of stereotactic radiosurgery/stereotactic body radiotherapy/stereotactic ablative radiotherapy practice using tomoedge in helical tomotherapy for lung, liver, and spine targets

被引:3
|
作者
Sresty, N. V. N. Madhusudhana [1 ]
Raju, A. Krishnam [1 ]
Kumar, G. Deleep [1 ]
Rohit, S. [1 ]
Reddy, B. Nagarjuna [1 ]
Sahithya, V. C. [1 ]
Reddy, B. Devender [1 ]
Mohd, Yakub [1 ]
Rushdi, Tasneem [1 ]
Bajwa, Harjoth [1 ]
Aparna, S. [2 ]
机构
[1] Basavatarakam Indo Amer Canc Hosp & Res Inst, Dept Radiotherapy, Rd 14,Banjara Hills, Hyderabad 500034, Telangana, India
[2] MNJ Inst Oncol & RCC, Dept Radiotherapy, Hyderabad, Telangana, India
关键词
Stereotactic radiosurgery; stereotactic body radiotherapy; stereotactic ablative radiotherapy; TomoEDGE; TomoTherapy; treatment time; RADIATION-THERAPY; TREATMENT PLANS; CONFORMITY; QUALITY; INDEX;
D O I
10.4103/jmp.JMP_97_20
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The primary purpose of the study is to evaluate the implementation of Helical TomoTherapy (HT) for eligible stereotactic radiosurgery/stereotactic body radiotherapy/stereotactic ablative radiotherapy (SRS/SBRT/SABR) cases using TomoEDGE option. The study focuses on reduction of treatment time without compromise in plan quality using TomoEDGE. It is a mode in HT that uses a dynamic opening of the jaws during treatment delivery to reduce the dose penumbra which otherwise is not possible with fixed jaws option. Eligible SRS/SBRT/SABR cases of lung, liver, and spine were used in this study. All planning parameters such as dose prescription to target and critical organs, pitch, and modulation factor were same in all the plans of the same patient with modifications in the field width and jaw mode. First set of plans with 2.5 cm width and second set of plans with 5 cm width were done in dynamic TomoEDGE mode. Third set of plans created with 5 cm width fixed jaw mode and fourth set of plans with 2.5 cm fixed jaw mode for comparison purpose were done. Our observations achieved that a significant milestone with reduction of up to 34.3% in treatment time of liver cases, 35.2% in lung cases, and 28.7% in spine cases was observed using dynamic TomoEDGE mode with 5 cm width, while no significant variation in the planning results compared with plans using 2.5 cm dynamic TomoEDGE option. TomoEDGE is an efficient and useful mode in TomoTherapy to reduce the treatment time with bigger field width in SRS/SBRT/SABR cases without significant changes in the plan quality.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 50 条
  • [21] Approaches for Stereotactic Radiosurgery (SRS)/Stereotactic Radiotherapy (SRT) in brain metastases using different radiotherapy modalities (Feasibility study)
    Tawfik, Zyad A.
    Farid, Mohamed El-Azab
    El Shahat, Khaled M.
    Hussein, Ahmed A.
    Al Etreby, Mostafa
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (03) : 765 - 781
  • [22] Pulmonary function in stereotactic body radiotherapy with helical tomotherapy for primary and metastatic lung lesions
    Falcinelli, Lorenzo
    Mendichi, Monia
    Chierchini, Sara
    Tenti, Maria Valentina
    Bellavita, Rita
    Saldi, Simonetta
    Ingrosso, Gianluca
    Reggioli, Valentina
    Bini, Vittorio
    Aristei, Cynthia
    RADIOLOGIA MEDICA, 2021, 126 (01): : 163 - 169
  • [23] Stereotactic body radiotherapy with helical tomotherapy for lung tumors: A single-center experience
    Figlia, V.
    Cuccia, F.
    Valenti, V.
    Tripoli, A.
    Terranova, G.
    Lo Casto, A.
    Failla, G.
    Cucchiara, T.
    Mortellaro, G.
    Ferrera, G.
    JOURNAL OF THORACIC ONCOLOGY, 2018, 13 (04) : S136 - S136
  • [24] The Distribution and Patterns of Practice of Stereotactic Ablative Body Radiotherapy in Canada
    Lund, Chad R.
    Cao, Jeffrey Q.
    Liu, Mitchell
    Olson, Robert
    Halperin, Ross
    Schellenberg, Devin
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2014, 45 (01) : 8 - 15
  • [25] Stereotactic Body Radiotherapy of Spine Metastasis
    Sunyoung, L.
    Chung, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S582 - S582
  • [26] A review of stereotactic body radiotherapy for the spine
    James Rijken
    Scott Crowe
    Jamie Trapp
    Tanya Kairn
    Physical and Engineering Sciences in Medicine, 2020, 43 : 799 - 824
  • [27] Stereotactic body radiotherapy of spine metastasis
    Lee, S.
    Min, C.
    Kim, G.
    Cho, D.
    Chung, W.
    JOURNAL OF CLINICAL ONCOLOGY, 2010, 28 (15)
  • [28] A review of stereotactic body radiotherapy for the spine
    Rijken, James
    Crowe, Scott
    Trapp, Jamie
    Kairn, Tanya
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (03) : 799 - 824
  • [29] Dosimetric Evaluation of Intracranial Stereotactic Radiotherapy with Helical Tomotherapy
    Sheth, N.
    Cheng, J.
    Jani, A.
    Sim, S.
    Murphy, S.
    Chen, Y.
    Stapleton, P.
    Winant, S.
    Yang, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [30] Further Considerations in Regards to Commissioning of Spine Stereotactic Ablative Body Radiotherapy
    Barker, C. L.
    King, J.
    Colaco, R.
    CLINICAL ONCOLOGY, 2023, 35 (01)