Measurement on gas temperature distribution by tunable diode laser absorption Spectroscopy

被引:0
|
作者
Li Ning [1 ]
Yan Jian-hua [1 ]
Wang Fei [1 ]
Chi Yong [1 ]
Cen Ke-fa [1 ]
机构
[1] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
关键词
tunable diode laser absorption spectroscopy; gas temperature distribution measurement; least-square fitting; discretization method;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The technique of tunable diode laser absorption spectroscopy (TDLAS) can be used for gas temperature distribution measurement by scanning multiple gas absorption lines with a tunable diode laser. The fundamental of gas temperature distribution measurement by TDLAS is introduced in the present paper, and the discretization strategy of equation for gas absorption is also given here. Using constrained linear least-square fitting method, the gas temperature distribution can be calculated with the help of physical constraints under the condition of uniform gas concentration and pressure. Based on the spectral parameters of four CO absorption lines near 6 330 cm(-1) from HITRAN database, the model of two-temperature distribution at 300 and 600 K with each path length of 55 cm was set up. The effects of relative measurement error and different path length constraints of temperature bins on the gas temperature distribution measurement results were simulated by constrained linear least-square fitting. The results show that the temperature distribution calculation error increases as the relative measurement error rises. A measurement error of 5% could lead to a maximum relative error of 11%, and an average relative error of 2.2% for calculation result. And the weak physical constraints of path length for temperature bins could increase the calculation result error during the process of constrained linear least-square fitting. By setting up the model of two-temperature distribution with gas cells at room temperature as the cold section and in tube furnace as the hot section, the experiment of gas temperature distribution measurement in lab was carried out. Using four absorption lines of CO near 6 330 cm(-1) scanned by VCSEL diode laser, and fitting the background laser intensity without absorption by the cubic polynomial to get the baseline signal, the integrals of spectral absorbance for gas temperature distribution measurement can be calculated. The relative calculation errors of path length for temperature bins are about 7.3%, 6.5%, 4.7% and 2.7% in the four cases.
引用
收藏
页码:1708 / 1712
页数:5
相关论文
共 50 条
  • [11] Numerical investigation of the two-dimensional gas temperature distribution based on tunable diode laser absorption spectroscopy
    Shao, Jie
    Wang, LiMing
    Ying, Chaofu
    [J]. OPTICA APPLICATA, 2015, 45 (02) : 183 - 198
  • [12] OXYGEN CONCENTRATION AND TEMPERATURE SIMULTANEOUS MEASUREMENT BASED ON TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY
    Zhang, Chun-Xiao
    Wang, Fei
    Zheng, Qi-Ming
    Yan, Jianhua
    Chi, Yong
    Cen, Ke-fa
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 2, 2009, : 147 - 150
  • [13] Carbon Monoxide Measurement at Elevated Temperature Based on Tunable Diode Laser Absorption Spectroscopy
    Guo Yan-Lin
    Huang Xiao
    Hong Yi
    Dong Jun-Guo
    Gao Wei
    Li Mei
    Huang Zheng-Xu
    Fu Zhong
    Cheng Ping
    Zhou Zhen
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (08) : 1247 - 1254
  • [14] CO CONCENTRATION MEASUREMENT IN THE HIGH TEMPERATURE FLAME WITH TUNABLE DIODE LASER ABSORPTION SPECTROSCOPY
    Xu, Ting
    Wang, Fei
    Jiang, Zhishen
    Yan, Jianhua
    Cen, Kefa
    Yuan, Ke
    Xiao, Huiping
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE - 2011, VOL 1, 2012, : 271 - +
  • [15] Temperature measurements based on tunable diode laser absorption spectroscopy
    Xu Zhen-Yu
    Liu Wen-Qing
    Liu Jian-Guo
    He Jun-Feng
    Yao Lu
    Ruan Jun
    Chen Jiu-Ying
    Li Han
    Yuan Song
    Geng Hui
    Kan Rui-Feng
    [J]. ACTA PHYSICA SINICA, 2012, 61 (23)
  • [16] Validation of temperature measurement for a tunable diode laser absorption sensor
    Wang, Guangyu
    Hong, Yanji
    Pan, Hu
    Song, Junling
    [J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2013, 42 (09): : 2358 - 2363
  • [17] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Xilong YuFei LiLihong ChenXinyu Zhang Key Laboratory of High Temperature Gas Dynamics Institute of MechanicsChinese Academy of Sciences BeijingChina
    [J]. Acta Mechanica Sinica, 2010, 26 (01) : 147 - 149
  • [18] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Yu, Xilong
    Li, Fei
    Chen, Lihong
    Zhang, Xinyu
    [J]. ACTA MECHANICA SINICA, 2010, 26 (01) : 147 - 149
  • [19] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Xilong Yu
    Fei Li
    Lihong Chen
    Xinyu Zhang
    [J]. Acta Mechanica Sinica, 2010, 26 : 147 - 149
  • [20] Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser
    Xilong Yu.Fei Li.Lihong Chen.Xinyu Zhang Key Laboratory of High Temperature Gas Dynamics
    [J]. Acta Mechanica Sinica, 2010, (01) : 147 - 149