Dynamic analysis of the measurement data of energy-efficient building envelope

被引:0
|
作者
Fan, R [1 ]
Zhao, LH [1 ]
Zhang, HS [1 ]
机构
[1] Harbin Inst Technol, Sch Municipal & Environm Engn, Harbin 150090, Peoples R China
关键词
measurement of heat transfer coefficient; dynamic analysis method; test duration;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The heat flowmeter method is suitable for the measurement of overall heat transfer coefficient of building envelope. The average method is often used for analysis of the data, which is applicable under such cases with much longer test duration and small oscillations in indoor and outdoor temperature. However, for heavy elements submitted to variable indoor and outdoor temperature, the dynamic analysis method should be used in accordance with International Standard (ISO9869). The dynamic analysis method may shorten the test duration without degrading the precision, but which is too complex to be used. The author programs to analyze the data with the dynamic method. This program is also used to analyze the data obtained at night, in the daytime and in the whole day respectively so as to know their effects on real values.
引用
收藏
页码:576 / 582
页数:7
相关论文
共 50 条
  • [41] Advances and challenges in building engineering and data mining applications for energy-efficient communities
    Yu, Zhun
    Haghighat, Fariborz
    Fung, Benjamin C. M.
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2016, 25 : 33 - 38
  • [42] Energy-efficient dynamic clusters of servers
    Dilawaer Duolikun
    Tomoya Enokido
    Ailixier Aikebaier
    Makoto Takizawa
    [J]. The Journal of Supercomputing, 2015, 71 : 1642 - 1656
  • [43] Energy-efficient Dynamic Clusters of Servers
    Doulikun, Dilawaer
    Aikebaier, Ailixier
    Enokido, Tomoya
    Takizawa, Makoto
    [J]. 2013 EIGHTH INTERNATIONAL CONFERENCE ON BROADBAND, WIRELESS COMPUTING, COMMUNICATION AND APPLICATIONS (BWCCA 2013), 2013, : 253 - 260
  • [44] Energy-efficient dynamic clusters of servers
    Duolikun, Dilawaer
    Enokido, Tomoya
    Aikebaier, Ailixier
    Takizawa, Makoto
    [J]. JOURNAL OF SUPERCOMPUTING, 2015, 71 (05): : 1642 - 1656
  • [45] Energy Consumption of an Energy Efficient Building Envelope in the Canadian Arctic
    Banister, Carsen
    Swinton, Michael
    Moore, Travis
    Krys, Dennis
    Macdonald, Iain
    [J]. COLD CLIMATE HVAC 2018: SUSTAINABLE BUILDINGS IN COLD CLIMATES, 2019, : 29 - 39
  • [46] Advances in Energy-Efficient Building Systems and Operation
    Memari, Ali M.
    [J]. JOURNAL OF ARCHITECTURAL ENGINEERING, 2021, 27 (03)
  • [47] Energy-efficient retrofit of an unconditioned institute building
    Sharma, Aanchal
    Chani, P. S.
    Kulkarni, S. Y.
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2014, 57 (01) : 49 - 62
  • [48] OPTIMIZATION APPLIED TO DESIGN OF AN ENERGY-EFFICIENT BUILDING
    JUROVICS, SA
    [J]. IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1978, 22 (04) : 378 - 385
  • [49] Plastics' key role in energy-efficient building
    Krawczak, P.
    [J]. EXPRESS POLYMER LETTERS, 2009, 3 (12): : 752 - 752
  • [50] An optimal operational scheduling model for energy-efficient building with dynamic heat loss prediction
    Zheng, Peijun
    Liu, Jiang
    Liu, Peng
    Nakanishi, Yosuke
    [J]. ENERGY AND BUILDINGS, 2023, 280