Research and realization of auto-calibration technique based on structured grating 3D measuring system

被引:1
|
作者
Cheng, J. T. [1 ]
Zhao, C. [1 ]
He, W. T. [1 ]
机构
[1] Heilongjiang Univ Sci & Technol, Inst Engn Mech, Harbin, Heilongjiang Pr, Peoples R China
关键词
auto-calibration; grating measuring random placing; regular number;
D O I
10.4028/www.scientific.net/AMM.10-12.594
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduced present application in the world and some problems in the calibration technique of 3D measuring system. Auto-calibration technique of multiple targets tracking for detecting outline based on random placement and regular number is put forward. At the same time, the concrete algorithm is given. Then, according to the algorithm, the corresponding experimental result is obtained. Furthermore, the calibration accuracy is compared and analyzed. Finally, it comes to a conclusion that this algorithm can make the operation more simple and convenient. And the calibration accuracy is kept within 0.03mm.
引用
收藏
页码:594 / 598
页数:5
相关论文
共 50 条
  • [41] Calibration of 3D imaging system based on Multi-line Structured-light
    Zou Yi
    Niu Li Hong
    Su Binghua
    Sun Yushun
    Liu Jinyuan
    [J]. THREE-DIMENSIONAL IMAGE ACQUISITION AND DISPLAY TECHNOLOGY AND APPLICATIONS, 2018, 10845
  • [42] 3D Auto-Calibration Method for Head-Mounted Binocular Gaze Tracker as Human-Robot Interface
    Kwon, Su Hyun
    Kim, Min Young
    [J]. PROCEEDINGS OF THE 8TH ACM/IEEE INTERNATIONAL CONFERENCE ON HUMAN-ROBOT INTERACTION (HRI 2013), 2013, : 171 - 172
  • [43] Calibration for 3D Structured Light Measurement
    郝丽俊
    程胜
    陈亚珠
    [J]. Journal of Shanghai Jiaotong University(Science), 2007, (05) : 572 - 576
  • [44] Calibration for 3D structured light measurement
    Hao, Li-Jun
    Cheng, Sheng
    Chen, Ya-Zhu
    [J]. Journal of Shanghai Jiaotong University (Science), 2007, 12 E (05) : 572 - 576
  • [45] Realization of spectrum auto-shifting in 3-D object shapes optical measuring technique based on convolution filtering
    Yang, Fujun
    Yu, Wanming
    Yun, Dazhen
    Jin, Yan
    [J]. Dalian Ligong Daxue Xuebao/Journal of Dalian University of Technology, 2000, 40 (02): : 148 - 150
  • [46] Research on the Realization of 3D Animation Propagation Based on the Internet
    Pu, Jing
    Hu, Rui
    Shi, Chen
    Xiang, Yuwei
    [J]. PROCEEDINGS OF THE 2017 4TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND COMPUTER (MACMC 2017), 2017, 150 : 192 - 195
  • [47] Fully 3D geometrical calibration for an X-ray grating-based imaging system
    Chen, Mianyi
    Yang, Qingsong
    Cong, Wenxiang
    Wei, Biao
    Wang, Ge
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (06) : 821 - 836
  • [48] LINE OF SIGHT AUTO-CALIBRATION FOR CO3D ROLLING SHUTTER MATRIX DETECTOR
    Vidal, B.
    Laurent, G.
    Buffe, F.
    Binet, R.
    Zanga, W.
    Greslou, D.
    [J]. XXIV ISPRS CONGRESS CONGRESS IMAGING TODAY, FORESEEING TOMORROW, COMMISSION I, 2022, 43-B1 : 107 - 112
  • [49] Research on 3D Measuring Based Binocular Vision
    Yan, Long
    Zhao, Xingfang
    Du, Huiqiu
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON CONTROL SCIENCE AND SYSTEMS ENGINEERING, 2014, : 18 - 26
  • [50] Complete calibration of a phase-based 3D imaging system based on fringe projection technique
    Meng, Shasha
    Ma, Haiyan
    Zhang, Zonghua
    Guo, Tong
    Zhang, Sixiang
    Hu, Xiaotang
    [J]. 2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC IMAGING AND PROCESSING TECHNOLOGY, 2011, 8200