A combined polarized target/ionization chamber for measuring the spin dependence of nuclear muon capture in laser polarized muonic He-3

被引:1
|
作者
Bogorad, P
Brash, EJ
Cates, GD
Cummings, WJ
Gorelov, A
Hasinoff, MD
Hausser, O
Hicks, K
Holmes, R
Huang, JC
Krieger, D
Kumar, KS
Larson, B
Lorenzon, W
McCracken, J
Michaux, P
Middleton, H
Saettler, E
Siegel, D
Souder, PA
Swenson, DR
Thywissen, J
Tupa, D
Ullom, J
Wang, X
Young, AR
机构
[1] PRINCETON UNIV,PRINCETON,NJ 08544
[2] RUTGERS STATE UNIV,PISCATAWAY,NJ 08855
[3] TRIUMF,VANCOUVER,BC V6T 2A3,CANADA
[4] SIMON FRASER UNIV,BURNABY,BC V5A 1S6,CANADA
[5] UNIV BRITISH COLUMBIA,VANCOUVER,BC V6T 1Z,CANADA
[6] OHIO UNIV,ATHENS,OH 45701
[7] SYRACUSE UNIV,SYRACUSE,NY 13244
[8] UNIV PENN,PHILADELPHIA,PA 19104
[9] UNIV CALIF LOS ALAMOS NATL LAB,LOS ALAMOS,NM
关键词
muon; pseudoscalar; ionization chamber; polarized target;
D O I
10.1016/S0168-9002(97)00873-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a device used in experiment 1231 at LAMPF and in e683 at TRIUMF to study the spin dependence of the reaction mu(-) + He-3 --> H-3 + nu(mu). In order to study the spin dependence, we needed to form and polarize muonic He-3 and in the same volume detect the 1.9 MeV tritons created in the reaction. Furthermore, the recoil direction of the tritons had to be determined. The apparatus served both as a polarized target and as a detector. The detector, a gridded ion chamber, was incorporated inside a 51 polarized target that was filled with 8 atm of He-3 and 100 Torr of N-2 and rubidium metal. At the operating temperature of the device (205-230 degrees C), the rubidium number density was approximately 10(15) atoms/cm(3). Muons that stopped in the target formed muonic helium atoms, which were then polarized by collisions with optically pumped Rb vapor. Two high-powered GaAlAs diode laser arrays were used to polarize the Rb in the 100 cm(3) fiducial volume located inside the ion chamber. The ion chamber produced clean signals from the reaction tritons despite having to operate under the extreme conditions required for efficient optical pumping. The direction of the tritons was determined by analyzing the shapes of the ionization pulses. The muon polarization was measured using the decay electron asymmetry.
引用
下载
收藏
页码:211 / 223
页数:13
相关论文
共 50 条
  • [41] STUDY OF MECHANICAL COMPRESSION OF SPIN-POLARIZED HE-3 GAS
    BECKER, J
    HEIL, W
    KRUG, B
    LEDUC, M
    MEYERHOFF, M
    NACHER, PJ
    OTTEN, EW
    PROKSCHA, T
    SCHEARER, LD
    SURKAU, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2): : 45 - 51
  • [42] PHASE-TRANSITIONS IN PARTIALLY SPIN-POLARIZED HE-3
    BARRANCO, M
    POLLS, A
    STRINGARI, S
    NACHER, PJ
    LALOE, F
    JOURNAL DE PHYSIQUE, 1987, 48 (C-2): : 101 - 106
  • [43] THE SLAC HIGH-DENSITY GASEOUS POLARIZED HE-3 TARGET
    JOHNSON, JR
    THOMPSON, AK
    CHUPP, TE
    SMITH, TB
    CATES, GD
    DRIEHUYS, B
    MIDDLETON, H
    NEWBURY, NR
    HUGHES, EW
    MEYER, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 356 (01): : 148 - 152
  • [44] EVIDENCE FOR VISCOSITY REDUCTION IN MODERATELY SPIN-POLARIZED HE-3
    KOPIETZ, P
    DUTTA, A
    ARCHIE, CN
    PHYSICAL REVIEW LETTERS, 1986, 57 (10) : 1231 - 1234
  • [45] SPIN-POLARIZED HE-3, A PLAYGROUND IN MANY DOMAINS OF PHYSICS
    LEDUC, M
    JOURNAL DE PHYSIQUE, 1990, 51 (22): : C6317 - C6331
  • [46] MACROSCOPIC QUANTUM-PROPERTIES OF SPIN-POLARIZED HE-3
    LHUILLIER, C
    PHYSICA SCRIPTA, 1987, 36 (01): : 107 - 111
  • [47] AN INTERNAL POLARIZED HE-3 TARGET FOR ELECTRON STORAGE-RINGS
    KRAMER, LH
    DESCHEPPER, D
    MILNER, RG
    PATE, SF
    SHIN, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 362 (01): : 32 - 35
  • [48] STUDY OF SPIN RELAXATION BY A CHARGED-PARTICLE BEAM IN A POLARIZED HE-3 GAS-TARGET
    MILNER, RG
    MCKEOWN, RD
    WOODWARD, CE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 257 (02): : 286 - 290
  • [49] Measurement of the neutron spin structure function g(1)(n) with a polarized He-3 internal target
    Ackerstaff, K
    Airapetian, A
    Akushevich, I
    Akopov, N
    Amarian, M
    Aschenauer, EC
    Avakian, R
    Avakian, H
    Avetissian, A
    Bains, B
    Barrow, S
    Beckmann, M
    Belostotski, S
    Belz, JE
    Benisch, T
    Bernreuther, S
    Bianchi, N
    Blanchard, S
    Blouw, J
    Bottcher, H
    Borissov, A
    Brack, J
    Braun, B
    Bray, B
    Bruckner, W
    Brull, A
    Bruins, EEW
    Bulten, HJ
    Capitani, GP
    Carter, P
    Cisbani, E
    Court, GR
    Delheij, PPJ
    Devitsin, E
    deJager, CW
    DeSanctis, E
    DeSchepper, D
    Huberts, PKAD
    Duren, M
    Dvoredsky, A
    Elbakian, G
    Emerson, J
    Fantoni, A
    Fechtchenko, A
    Ferstl, M
    Fick, D
    Fiedler, K
    Filippone, BW
    Fischer, H
    Fortune, HT
    PHYSICS LETTERS B, 1997, 404 (3-4) : 383 - 389
  • [50] THE SOLUBILITY OF SPIN-POLARIZED HE-3 IN HE-4 AND THE SUPERFLUIDITY OF HE-3 IN HE-3-HE-4 MIXTURES
    ROOBOL, LP
    FROSSATI, G
    BEDELL, KS
    MEYEROVICH, AE
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1995, 100 (3-4) : 339 - 363