A combined polarized target/ionization chamber for measuring the spin dependence of nuclear muon capture in laser polarized muonic He-3

被引:1
|
作者
Bogorad, P
Brash, EJ
Cates, GD
Cummings, WJ
Gorelov, A
Hasinoff, MD
Hausser, O
Hicks, K
Holmes, R
Huang, JC
Krieger, D
Kumar, KS
Larson, B
Lorenzon, W
McCracken, J
Michaux, P
Middleton, H
Saettler, E
Siegel, D
Souder, PA
Swenson, DR
Thywissen, J
Tupa, D
Ullom, J
Wang, X
Young, AR
机构
[1] PRINCETON UNIV,PRINCETON,NJ 08544
[2] RUTGERS STATE UNIV,PISCATAWAY,NJ 08855
[3] TRIUMF,VANCOUVER,BC V6T 2A3,CANADA
[4] SIMON FRASER UNIV,BURNABY,BC V5A 1S6,CANADA
[5] UNIV BRITISH COLUMBIA,VANCOUVER,BC V6T 1Z,CANADA
[6] OHIO UNIV,ATHENS,OH 45701
[7] SYRACUSE UNIV,SYRACUSE,NY 13244
[8] UNIV PENN,PHILADELPHIA,PA 19104
[9] UNIV CALIF LOS ALAMOS NATL LAB,LOS ALAMOS,NM
关键词
muon; pseudoscalar; ionization chamber; polarized target;
D O I
10.1016/S0168-9002(97)00873-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a device used in experiment 1231 at LAMPF and in e683 at TRIUMF to study the spin dependence of the reaction mu(-) + He-3 --> H-3 + nu(mu). In order to study the spin dependence, we needed to form and polarize muonic He-3 and in the same volume detect the 1.9 MeV tritons created in the reaction. Furthermore, the recoil direction of the tritons had to be determined. The apparatus served both as a polarized target and as a detector. The detector, a gridded ion chamber, was incorporated inside a 51 polarized target that was filled with 8 atm of He-3 and 100 Torr of N-2 and rubidium metal. At the operating temperature of the device (205-230 degrees C), the rubidium number density was approximately 10(15) atoms/cm(3). Muons that stopped in the target formed muonic helium atoms, which were then polarized by collisions with optically pumped Rb vapor. Two high-powered GaAlAs diode laser arrays were used to polarize the Rb in the 100 cm(3) fiducial volume located inside the ion chamber. The ion chamber produced clean signals from the reaction tritons despite having to operate under the extreme conditions required for efficient optical pumping. The direction of the tritons was determined by analyzing the shapes of the ionization pulses. The muon polarization was measured using the decay electron asymmetry.
引用
下载
收藏
页码:211 / 223
页数:13
相关论文
共 50 条
  • [1] Experiments with polarized He-3 and muonic He-3: Pion elastic scattering and muon capture
    Hausser, O
    MESONS AND LIGHT NUCLEI '95, 1996, 9 : 69 - 82
  • [2] Laser polarized muonic 3He and spin dependent μ- capture
    Syracuse Univ, Syracuse, United States
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 402 (2-3): : 311 - 318
  • [3] Laser polarized muonic 3He and spin dependent μ- capture
    Souder, PA
    Bogorad, PL
    Brash, EJ
    Cates, GD
    Cummings, WJ
    Gorelov, A
    Hasinoff, MD
    Hausser, O
    Hicks, K
    Holmes, R
    Huang, JC
    Kumar, KS
    Larson, B
    Lorenzon, W
    McCracken, J
    Michaux, P
    Middleton, H
    Saettler, E
    Siegel, D
    Tupa, D
    Wang, X
    Young, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 402 (2-3): : 311 - 318
  • [4] SPIN POLARIZED HE-3
    LHUILLIER, C
    LECTURE NOTES IN PHYSICS, 1984, 198 : 189 - 199
  • [5] A POLARIZED HE-3 TARGET FOR NUCLEAR-PHYSICS
    MILNER, RG
    MCKEOWN, RD
    WOODWARD, CE
    NUCLEAR PHYSICS A, 1989, 497 : C495 - C508
  • [6] A POLARIZED HE-3 TARGET FOR NUCLEAR-PHYSICS
    MILNER, RG
    MCKEOWN, RD
    WOODWARD, CE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (1-2): : 56 - 63
  • [7] ADIABATIC SPIN ROTATOR FOR A LASER-PUMPED POLARIZED HE-3 TARGET
    CUMMINGS, WJ
    BRASH, EJ
    HAUSSER, O
    BAHRAMI, M
    GRAHAM, J
    HAUSER, P
    DELHEIJ, PPJ
    HENDERSON, RS
    VETTERLI, MC
    WHITTAL, DM
    LARSON, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2): : 52 - 56
  • [8] Laser-polarized muonic He-3 and a measurement of the induced pseudoscalar coupling
    Bogorad, P
    Behr, J
    Brash, EJ
    Cates, GD
    Cummings, WJ
    Gorelov, A
    Hasinoff, MD
    Hausser, O
    Hicks, K
    Holmes, R
    Huang, JC
    Kumar, KS
    Larson, B
    Lorentzon, W
    McCracken, J
    Middleton, H
    Michaux, P
    Saettler, E
    Siegel, D
    Souder, PA
    Swenson, DR
    Tupa, D
    Wang, X
    Young, A
    HYPERFINE INTERACTIONS, 1996, 102 : 433 - 437
  • [9] POLARIZED HE-3 TARGET CONSTRUCTION
    HARDY, DM
    BOYKIN, WR
    BAKER, SD
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (01): : 141 - &
  • [10] EXPERIENCE WITH A POLARIZED HE-3 TARGET FOR NUCLEAR-SCATTERING EXPERIMENTS
    VERHEIJEN, PJT
    MCCAMIS, RH
    DRAKOPOULOS, P
    VANOERS, WTH
    DANIELS, JM
    MAY, AD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (01): : 71 - 76