Mass transfer in a pulsed and non-pulsed disc and doughnut (PDD) solvent extraction column

被引:25
|
作者
Wang, Yong [1 ]
Yi, Heng [1 ]
Smith, Kathryn H. [1 ]
Mumford, Kathryn A. [1 ]
Stevens, Geoffrey W. [1 ]
机构
[1] Univ Melbourne, Dept Chem & Biomol Engn, Particulate Fluids Proc Ctr, Parkville, Vic 3010, Australia
基金
澳大利亚研究理事会;
关键词
Mass transfer coefficient; Height of mass transfer unit; Pulsing and non-pulsing; Disc and doughnut column; Solvent extraction; LIQUID-LIQUID-EXTRACTION; TRANSFER COEFFICIENTS; PREDICTION; PERFORMANCE;
D O I
10.1016/j.ces.2017.02.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Mechanical agitation or pulsation is usually introduced to a solvent extraction column to improve the efficiency. Recently a number of industrial scale pulsed disc and doughnut (PDD) solvent extraction columns have been found to have higher extraction efficiency while running with non-pulsing. In this study, the mass transfer performance of a PDD column was measured under pulsing and non-pulsing conditions using a 72.5 mm diameter disc and doughnut column. The effects of pulsation intensity and dispersed and continuous phase velocity on the mass transfer performance have been investigated. The results show that, under non-pulsing conditions, the overall mass transfer coefficient increased with increasing continuous phase flow rate and slightly decreased with increasing dispersed phase flow rate. With increasing pulsation intensity, the overall mass transfer coefficient decreased at first and then increased. Two correlations are proposed to predict the height of mass transfer unit and overall mass transfer coefficient in a PDD column including pulsing and non-pulsing conditions. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:48 / 54
页数:7
相关论文
共 50 条
  • [11] Investigation of hydrodynamic and mass transfer of mercaptan extraction in pulsed and non-pulsed packed columns
    Pouria Amani
    Mohammad Amani
    Reza Hasanvandian
    Korean Journal of Chemical Engineering, 2017, 34 : 1456 - 1465
  • [12] Investigation of hydrodynamic and mass transfer of mercaptan extraction in pulsed and non-pulsed packed columns
    Amani, Pouria
    Amani, Mohammad
    Hasanvandian, Reza
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2017, 34 (05) : 1456 - 1465
  • [13] Comparison of the performance of a pulsed disc and doughnut column with a pulsed sieve plate liquid extraction column
    Jahya, AB
    Pratt, HRC
    Stevens, GW
    SOLVENT EXTRACTION AND ION EXCHANGE, 2005, 23 (03) : 307 - 317
  • [14] Performance of an Industrial Pulsed Disc-and-Doughnut Extraction Column
    Wang, Yong
    Mumford, Kathryn A.
    Smith, Kathryn H.
    Ballestrin, Simon
    Li, Zheng
    Stevens, Geoffrey W.
    SOLVENT EXTRACTION AND ION EXCHANGE, 2016, 34 (02) : 161 - 171
  • [15] Flooding and drop size in a pulsed disc and doughnut extraction column
    Torab-Mostaedi, Meisam
    Ghaemi, Ahad
    Asadollahzadeh, Mehdi
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (12A): : 2742 - 2751
  • [16] DISPERSED PHASE HOLDUP IN A PULSED DISC AND DOUGHNUT EXTRACTION COLUMN
    Torab-Mostaedi, M.
    Jalilvand, H.
    Outokesh, M.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2011, 28 (02) : 313 - 323
  • [17] Recycling of zinc ions in disc-donut column considering forward mixing mass transfer, and effects of pulsed and non-pulsed condition
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    Saremi, Mojtaba
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [18] Modeling dispersed phase holdup and conditions of flooding in a pulsed disc and doughnut solvent extraction column
    Sinha, V.
    Vincent, T.
    Pera-Titus, M.
    CHEMICAL ENGINEERING JOURNAL, 2025, 505
  • [19] Recycling of zinc ions in disc-donut column considering forward mixing mass transfer, and effects of pulsed and non-pulsed condition
    Mehdi Asadollahzadeh
    Rezvan Torkaman
    Meisam Torab-Mostaedi
    Mojtaba Saremi
    Scientific Reports, 12
  • [20] AXIAL MIXING AND MASS TRANSFER PERFORMANCE OF AN ANNULAR PULSED DISC-AND-DOUGHNUT COLUMN
    Liu, Jian-Quan
    Li, Shao-Wei
    Jing, Shan
    SOLVENT EXTRACTION AND ION EXCHANGE, 2015, 33 (06) : 592 - 606