Mass transfer in a pulsed and non-pulsed disc and doughnut (PDD) solvent extraction column

被引:25
|
作者
Wang, Yong [1 ]
Yi, Heng [1 ]
Smith, Kathryn H. [1 ]
Mumford, Kathryn A. [1 ]
Stevens, Geoffrey W. [1 ]
机构
[1] Univ Melbourne, Dept Chem & Biomol Engn, Particulate Fluids Proc Ctr, Parkville, Vic 3010, Australia
基金
澳大利亚研究理事会;
关键词
Mass transfer coefficient; Height of mass transfer unit; Pulsing and non-pulsing; Disc and doughnut column; Solvent extraction; LIQUID-LIQUID-EXTRACTION; TRANSFER COEFFICIENTS; PREDICTION; PERFORMANCE;
D O I
10.1016/j.ces.2017.02.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Mechanical agitation or pulsation is usually introduced to a solvent extraction column to improve the efficiency. Recently a number of industrial scale pulsed disc and doughnut (PDD) solvent extraction columns have been found to have higher extraction efficiency while running with non-pulsing. In this study, the mass transfer performance of a PDD column was measured under pulsing and non-pulsing conditions using a 72.5 mm diameter disc and doughnut column. The effects of pulsation intensity and dispersed and continuous phase velocity on the mass transfer performance have been investigated. The results show that, under non-pulsing conditions, the overall mass transfer coefficient increased with increasing continuous phase flow rate and slightly decreased with increasing dispersed phase flow rate. With increasing pulsation intensity, the overall mass transfer coefficient decreased at first and then increased. Two correlations are proposed to predict the height of mass transfer unit and overall mass transfer coefficient in a PDD column including pulsing and non-pulsing conditions. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:48 / 54
页数:7
相关论文
共 50 条
  • [1] Prediction of drop size in a pulsed and non-pulsed disc and doughnut solvent extraction column
    Wang, Yong
    Smith, Kathryn H.
    Mumford, Kathryn A.
    Yi, Heng
    Wang, Lina
    Stevens, Geoffrey W.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 109 : 667 - 674
  • [2] Study of mass transfer and emphasis on pulsed and non-pulsed conditions for implementing cobalt extraction in the pilot plant column with disc and doughnut configuration
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 161
  • [3] Mass transfer studies for a pulsed disc and doughnut extraction column
    Jahya, AB
    Stevens, GW
    Pratt, HRC
    MINPREX 2000: INTERNATIONAL CONGRESS ON MINERAL PROCESSING AND EXTRACTIVE METALLURGY, 2000, 2000 (05): : 281 - 284
  • [4] Prediction of mass transfer coefficients in a pulsed disc and doughnut extraction column
    Torab-Mostaedi, Meisam
    Ghaemi, Ahad
    Asadollahzadeh, Mehdi
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2012, 90 (06): : 1570 - 1578
  • [5] Extraction of caprolactam with an alternative benign solvent in a pulsed disc and doughnut column
    van Delden, M. L.
    Vos, G. S.
    Kuipers, N. J. M.
    de Haan, A. B.
    SOLVENT EXTRACTION AND ION EXCHANGE, 2007, 25 (05) : 639 - 664
  • [6] Axial Dispersion in a Pulsed and Nonpulsed Disc and Doughnut Solvent Extraction Column
    Wang, Yong
    Yi, Heng
    Smith, Kathryn H.
    Mumford, Kathryn A.
    Stevens, Geoffrey W.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2017, 56 (14) : 4052 - 4059
  • [7] MASS TRANSFER PERFORMANCE IN PULSED DISC AND DOUGHNUT EXTRACTION COLUMNS
    Torab-Mostaedi, M.
    Ghaemi, A.
    Asadollahzadeh, M.
    Pejmanzad, P.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2011, 28 (03) : 447 - 456
  • [8] CFD Simulation of Pulsed Disc and Doughnut Solvent Extraction Column on Industrial Grade
    Hou Y.
    Tan B.
    Wei G.
    Wang Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2021, 55 : 310 - 317
  • [9] Extraction of caprolactam with toluene in a pulsed disc and doughnut column - Part III: Mass transfer characteristics
    van Delden, M. L.
    Vos, G. S.
    Kuipers, N. J. M.
    de Haan, A. B.
    SOLVENT EXTRACTION AND ION EXCHANGE, 2006, 24 (04) : 539 - 564
  • [10] CFD Simulation of Liquid-Liquid Two-Phase Hydrodynamics and Axial Dispersion Analysis for a Non-Pulsed Disc and Doughnut Solvent Extraction Column
    Yi, Heng
    Wang, Yong
    Smith, Kathryn H.
    Fei, W. Y.
    Stevens, Geoffrey W.
    SOLVENT EXTRACTION AND ION EXCHANGE, 2016, 34 (06) : 535 - 548