Flow injection determination of thyroxine in pharmaceutical preparations using tris(2,2′-bipyridyl)ruthenium(III)-NADH chemiluminescence detection

被引:18
|
作者
Waseem, Amir [1 ]
Yaqoob, Mohammad [1 ]
Nabi, Abdul [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow injection analysis; chemiluminescence; thyroxine; NADH; pharmaceuticals;
D O I
10.1016/j.talanta.2006.03.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection (H) method is reported for the determination of thyroxine based on its enhancement of chemiluminescence (CL) from the Ru(bpy)(3) (3+)-NADH system. The calibration graph was linear over the range 2.0-10 x 10(-8) mol L-1 (r(2) = 0.9989) with relative standard deviations (R.S.D.) in the range 2.0-4.5% (n = 4). The limit of detection (3 sigma blank) was 1.0 x 10(-9) mol L-1 with sample throughput of 120 h-1. The effect of some organic compounds, anions and cations were studied for L-thyroxine determination. The method was applied to pharmaceutical preparations and the results obtained were in reasonable agreement with the amount labeled. The method was statistically compared with the results obtained by RIA; no significant disagreement at 95% confidence limit was observed. A calibration graph of NADH over the range 1.3 x 10(-8)-1.3 x 10(-6) mol L-1 was also established (r(2) = 0.9992) with R.S.D. in the range 1.0-3.5% (n = 4). The limit of detection (3 sigma) was 1.0 x 10(-10) mol L-1 NADH. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 50 条
  • [41] Determination of carbamazepine by chemiluminescence detection using chemically prepared tris(2,2′-bipyridine)-ruthenium(III) as oxidant
    Lee, SH
    Li, M
    Suh, JK
    ANALYTICAL SCIENCES, 2003, 19 (06) : 903 - 906
  • [42] Determination of Carbamazepine by Chemiluminescence Detection Using Chemically Prepared Tris(2,2’-bipyridine)- ruthenium(III) as Oxidant
    Sang Hak Lee
    Ming Li
    Jung Kee Suh
    Analytical Sciences, 2003, 19 : 903 - 906
  • [43] Chemiluminescence of tris(2,2′-bipyridyl)ruthenium(II):: A glowing experience
    Bolton, E
    Richter, MM
    JOURNAL OF CHEMICAL EDUCATION, 2001, 78 (01) : 47 - 48
  • [44] Coreactants of tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence
    Yuan, Yali
    Han, Shuang
    Hu, Lianzhe
    Parveen, Saima
    Xu, Guobao
    ELECTROCHIMICA ACTA, 2012, 82 : 484 - 492
  • [45] Flow-injection chemiluminescent determination of cefprozil using tris (2,2′-bipyridyl) ruthenium (II)-permanganate system
    Alarfaj, NA
    El-Razeq, SAA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1423 - 1427
  • [46] Highly sensitive determination of capsaicin with tris(2,2'-bipyridyl) ruthenium(II) electrogenerated chemiluminescence
    Lee, Sang Jung
    Lee, Won-Yong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 910
  • [47] Chemiluminescence Determination of Thiourea Using Tris(2,2′-bipyridyl)ruthenium(II)–KMnO4 System
    Zhike He
    Fengwu Wu
    Hui Meng
    Liansheng Ling
    Liangjie Yuan
    Qingyao Luo
    Yun’e Zeng
    Analytical Sciences, 1999, 15 : 381 - 383
  • [48] On-line chemical generation of tris(2,2′-bipyridyl)ruthenium(III) and its application in CE with chemiluminescence detection
    Ji, Xinghu
    He, Zhike
    Pang, Daiwen
    ELECTROPHORESIS, 2007, 28 (18) : 3260 - 3267
  • [49] Chemiluminescence determination of thiourea using tris(2,2′-bipyridyl)ruthenium(II)-KMnO4 system
    He, ZK
    Wu, FW
    Meng, H
    Ling, LS
    Yuan, LJ
    Luo, QY
    Zeng, YE
    ANALYTICAL SCIENCES, 1999, 15 (04) : 381 - 383
  • [50] Detection of furosemide with tris-(2,2′-bipyridyl) ruthenium-Ce(IV) chemiluminescence
    Zhang, SH
    Xi, J
    He, ZK
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (09) : 1269 - 1271