Hybrid nanomaterial/catalase-modified electrode for hydrogen peroxide sensing

被引:20
|
作者
Soto, Dayana [1 ]
Alzate, Manuela [2 ]
Gallego, Jaime [2 ]
Orozco, Jahir [1 ]
机构
[1] Univ Antioquia, Max Planck Tandem Grp Nanobioengn, Complejo Ruta N,Calle 67 52-20, Medellin, Colombia
[2] Univ Antioquia, Inst Quim, Quim Recursos Energet & Medio Ambiente, Calle 70 52-21, Medellin, Colombia
关键词
Hybrid nanomaterial; Graphene; Iron nanoparticles; Catalase; Direct electrochemistry;
D O I
10.1016/j.jelechem.2020.114826
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Conjugation of biomolecules with hybrid nanomaterials offer opportunities in the assembly of (bio)sensors of improved electrochemical performance. This work reports on developing a novel catalase-functionalized hybrid nanomaterial for the detection of hydrogen peroxide (H2O2). The rationally assembled (bio)sensor consists of iron nanoparticles coated with graphene's layers supported on multi-walled carbon nanotubes (Fe@G-MWCNTs), deposited at a screen-printed carbon electrode surface and functionalized with catalase. Transmission electron microscopy, X-ray diffraction-, X-ray photoelectron- and thermogravimetric-analysis were used to characterize the physicochemical properties of the hybrid nanomaterial and better understand its electrochemical behavior. The (bio)sensor response was linear from 0.1 to 7 mM, with a sensitivity of 0.059 ?A/(?M.cm2), a limit of detection of 28.2 ?M, a MichaelisMenten constant of 17.9 mM, and high reproducibility. The graphene flakes acted as a protective layer that prevented the loss of the Fe nanoparticles activity, thus improving the long-term stability of the (bio)sensor.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A gold electrode modified with a nanoparticulate film composed of a conducting copolymer for ultrasensitive voltammetric sensing of hydrogen peroxide
    Zhang, Rongli
    Jiang, Can
    Fan, Xiaoxia
    Yang, Renchun
    Sun, Yanyan
    Zhang, Cuige
    MICROCHIMICA ACTA, 2018, 185 (01)
  • [42] Electrochemically Reduced Graphene Oxide-nafion/Au Nanoparticle Modified Electrode for Hydrogen Peroxide Sensing
    Lv, Yajie
    Wang, Fang
    Zhu, Hui
    Zou, Xiaorong
    Tao, Cheng-An
    Wang, Jianfang
    NANOMATERIALS AND NANOTECHNOLOGY, 2016, 6
  • [43] Electrochemical study of PEDOT-PSS-MDB-modified electrode and its electrocatalytic sensing of hydrogen peroxide
    Siao, Hong-Wen
    Chen, Shen-Ming
    Lin, Kuo-Chiang
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (06) : 1121 - 1128
  • [44] REACTIONS OF CATALASE WITH HYDROGEN PEROXIDE AND HYDROGEN DONORS
    KEILIN, D
    NICHOLLS, P
    BIOCHIMICA ET BIOPHYSICA ACTA, 1958, 29 (02) : 302 - 307
  • [45] A catalase enzyme biosensor for hydrogen peroxide at a poly(safranine T)-ternary deep eutectic solvent and carbon nanotube modified electrode
    Zouleh, Razieh Seyfi
    Rahimnejad, Mostafa
    Najafpour-Darzi, Ghasem
    Sabour, Davood
    Almeida, Joseany M. S.
    Brett, Christopher M. A.
    MICROCHEMICAL JOURNAL, 2023, 195
  • [46] Editorial for Special Issue: "Preparation of Nanomaterial Modified Electrode and Its Sensing Application"
    Liu, Dong
    Yuan, Baiqing
    NANOMATERIALS, 2022, 12 (22)
  • [47] Amperometric biosensor for the detection of hydrogen peroxide using catalase modified electrodes in polyacrylamide
    Varma, S
    Mattiasson, B
    JOURNAL OF BIOTECHNOLOGY, 2005, 119 (02) : 172 - 180
  • [48] A new polyaniline-catalase-glutaraldehyde-modified biosensor for hydrogen peroxide detection
    Akyilmaz, Erol
    Oyman, Gizem
    Cinar, Ezgi
    Odabas, Gorkem
    PREPARATIVE BIOCHEMISTRY & BIOTECHNOLOGY, 2017, 47 (01): : 86 - 93
  • [49] Electrocatalytic reduction of hydrogen peroxide at nanostructured copper modified electrode
    Selvaraju, Thangavelu
    Ramaraj, Ramasamy
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (03) : 321 - 327
  • [50] Electrocatalytic reduction of hydrogen peroxide at nanostructured copper modified electrode
    Thangavelu Selvaraju
    Ramasamy Ramaraj
    Journal of Applied Electrochemistry, 2009, 39 : 321 - 327