Transdermal Drug Delivery in the Pig Skin

被引:7
|
作者
Ordiz, Ignacio [1 ]
Vega, Jose A. [1 ,2 ,3 ]
Martin-Sanz, Raquel [4 ]
Garcia-Suarez, Olivia [1 ,2 ]
del Valle, Miguel E. [1 ]
Feito, Jorge [2 ,5 ]
机构
[1] Univ Oviedo, Dept Morfol & Biol Celular, Oviedo 33006, Spain
[2] Univ Oviedo, Grp SINPOS, Oviedo 33006, Spain
[3] Univ Autonoma Chile, Fac Ciencias Salud, Santiago 7500912, Chile
[4] Complejo Asistencial Univ Salamanca, Serv Oftalmol, Salamanca 37007, Spain
[5] Complejo Asistencial Univ Salamanca, Serv Anat Patol, Salamanca 37007, Spain
关键词
transdermal delivery; intradermal injection; mesotherapy; microneedling; electroporation; skin; morphology; IN-VIVO; MICRONEEDLE ARRAYS; INTRADERMAL DELIVERY; ELECTROPORATION; MESOTHERAPY; KETOPROFEN; FORMULATIONS; MODEL; PAIN; IMMUNOHISTOCHEMISTRY;
D O I
10.3390/pharmaceutics13122016
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Transdermal delivery can be accomplished through various mechanisms including formulation optimization, epidermal stratum corneum barrier disruption, or directly by removing the stratum corneum layer. Microneedling, electroporation, a combination of both and also the intradermal injection known as mesotherapy have proved efficacy in epidermal-barrier disruption. Here we analyzed the effects of these methods of epidermal-barrier disruption in the structure of the skin and the absorption of four compounds with different characteristics and properties (ketoprofen, biotin, caffein, and procaine). Swine skin (Pietrain x Durox) was used as a human analogue, both having similar structure and pharmacological release. They were biopsied at different intervals, up to 2 weeks after application. High-pressure liquid chromatography and brightfield microscopy were performed, conducting a biometric analysis and measuring histological structure and vascular status. The performed experiments led to different results in the function of the studied molecules: ketoprofen and biotin had the best concentrations with intradermal injections, while delivery methods for obtaining procaine and caffein maximum concentrations changed on the basis of the lapsed time. The studied techniques did not produce significant histological alterations after their application, except for an observed increase in Langerhans cells and melanocytes after applying electroporation, and an epidermal thinning after using microneedles, with variable results regarding dermal thickness. Although all the studied barrier disruptors can accomplish transdermal delivery, the best disruptor is dependent on the particular molecule.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Investigation of newborn pig skin as an in vitro animal model for transdermal drug delivery
    Songkro, S
    Purwo, Y
    Becket, G
    Rades, T
    [J]. STP PHARMA SCIENCES, 2003, 13 (02): : 133 - 139
  • [2] Skin electroporation for transdermal drug delivery
    Vanbever, R
    Weaver, JC
    Préat, V
    [J]. ELECTRICITY AND MAGNETISM IN BIOLOGY AND MEDICINE, 1999, : 907 - 910
  • [3] THE SKIN COMPLIANCE OF TRANSDERMAL DRUG DELIVERY SYSTEMS
    BODDE, HE
    VERHOEVEN, J
    VANDRIEL, LMJ
    [J]. CRITICAL REVIEWS IN THERAPEUTIC DRUG CARRIER SYSTEMS, 1989, 6 (01): : 87 - 115
  • [4] SKIN COMPATIBILITY OF TRANSDERMAL DRUG DELIVERY SYSTEMS
    KURIHARABERGSTROM, T
    GOOD, WR
    FEISULLIN, S
    SIGNOR, C
    [J]. JOURNAL OF CONTROLLED RELEASE, 1991, 15 (03) : 271 - 278
  • [5] Skin Impedance Models for Transdermal Drug Delivery
    Pang, Grantham K. H.
    Qiao, DaPeng
    [J]. 2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, : 1784 - 1788
  • [6] A practical assessment of transdermal drug delivery by skin electroporation
    Prausnitz, MR
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 1999, 35 (01) : 61 - 76
  • [7] TRANSDERMAL DRUG DELIVERY SYSTEM WITH ENHANCED SKIN PERMEABILITY
    CHIEN, YW
    LEE, CS
    [J]. ACS SYMPOSIUM SERIES, 1987, 348 : 281 - 300
  • [8] The application of skin metabolomics in the context of transdermal drug delivery
    Jinling Li
    Weitong Xu
    Yibiao Liang
    Hui Wang
    [J]. Pharmacological Reports, 2017, 69 : 252 - 259
  • [9] TOWARDS SKIN COMPLIANT TRANSDERMAL DRUG DELIVERY SYSTEMS
    BODDE, HE
    TIEMESSEN, HLGM
    JUNGINGER, HE
    [J]. PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1987, 9 (02) : 150 - 150
  • [10] Transdermal drug delivery: An assessment of skin impedance models
    Coston, AF
    Li, JKJ
    [J]. PROCEEDINGS OF THE IEEE 29TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2003, : 319 - 320