Validity and reliability of clinical tests for assessing passive ankle stiffness

被引:18
|
作者
Araujo, Vanessa L. [1 ]
Carvalhais, Viviane O. C. [1 ]
Souza, Thales R. [1 ]
Ocarino, Juliana M. [1 ]
Goncalves, Gabriela G. P. [1 ]
Fonseca, Sergio T. [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Fisioterapia, Escola Educ Fis Fisioterapia & Terapia Ocupac, BR-31270901 Belo Horizonte, MG, Brazil
关键词
passive stiffness; clinical test; ankle; validity of tests; reproducibility of results; MUSCLE-STIFFNESS; CALF MUSCLES; RISK-FACTORS; JOINT; FLEXIBILITY; RANGE;
D O I
10.1590/S1413-35552011000200013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The presence of inadequate levels of passive ankle stiffness have been associated with the occurrence of movement disorders, the development of pathological conditions and the reduction in the performance of functional activities such as walking, running and jumping. Therefore, clinical tests to evaluate ankle stiffness may be useful for the physical therapy assessment. Objectives: To investigate the concurrent validity and the intra- and inter-examiner reliability of clinical measures developed to assess passive stiffness of the ankle joint during dorsiflexion movement. Methods: Fifteen healthy participants underwent to test-retest evaluations of their ankles by two examiners. Two clinical measures were performed: 'position of first detectable resistance' and 'change in passive resistance torque'. The results of these tests were compared to the passive stiffness measured with an isokinetic dynamometer, in which the electromyography activity of specific muscles was monitored to ensure that the test was performed passively (gold standard measure). Results: Pearson correlation coefficients ranged from r=-0.81 to -0.88 (p < 0.001) for the correlation between the passive ankle stiffness measured with the isokinetic dynamometer and the results of the clinical measure 'position of the first detectable resistance'. For the measure of 'change in passive resistance torque', these coefficients ranged from r=0.72 to 0.83 (p < 0.004). The Intraclass Correlation Coefficients (ICCs) for the intra- and inter-examiner reliability ranged from 0.75 to 0.98. Conclusion: The clinical measures presented satisfactory validity and reliability to be used in clinical practice.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 50 条
  • [1] Validity and reliability of clinical tests for assessing hip passive stiffness
    do Carmo Carvalhais, Viviane Otoni
    de Araujo, Vanessa Lara
    Souza, Thales Rezende
    Pavan Goncalves, Gabriela Gomes
    Ocarino, Juliana de Melo
    Fonseca, Sergio Teixeira
    [J]. MANUAL THERAPY, 2011, 16 (03) : 240 - 245
  • [2] Validity and reliability of a new in vivo ankle stiffness measurement device
    Zinder, Steven M.
    Granata, Kevin P.
    Padua, Darin A.
    Gansneder, Bruce M.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (02) : 463 - 467
  • [3] Reliability and validity of physical examination tests for the assessment of ankle instability
    Beynon, Amber
    Le May, Sylvie
    Theroux, Jean
    [J]. CHIROPRACTIC & MANUAL THERAPIES, 2022, 30 (01)
  • [4] Reliability and validity of physical examination tests for the assessment of ankle instability
    Amber Beynon
    Sylvie Le May
    Jean Theroux
    [J]. Chiropractic & Manual Therapies, 30
  • [5] A New Device for Assessing Ankle Dorsiflexion Motion: Reliability and Validity
    Wilken, Jason
    Rao, Smita
    Estin, Miriam
    Saltzman, Charles
    Yack, H. John
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2011, 41 (04): : 274 - 279
  • [6] ASSESSING THE RELIABILITY, DISCRIMINATIVE ABILITY, AND VALIDITY OF DISABILITY GLARE TESTS
    ELLIOTT, DB
    BULLIMORE, MA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (01) : 108 - 119
  • [7] AGE AND PASSIVE ANKLE STIFFNESS IN WOMEN
    CHESWORTH, BM
    VANDERVOORT, AA
    [J]. PHYSICAL THERAPY, 1988, 68 (05): : 820 - 821
  • [8] Reliability of clinical tests of foot and ankle characteristics in older people
    Menz, HB
    Tiedemann, A
    Kwan, MMS
    Latt, MD
    Sherrington, C
    Lord, SR
    [J]. JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2003, 93 (05) : 380 - 387
  • [9] Reliability and validity of ankle proprioceptive measures
    Deshpande, N
    Connelly, DM
    Culham, EG
    Costigan, PA
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (06): : 883 - 889
  • [10] Validity and reliability of clinical stability tests for upper cervical instability
    Kohn, V.
    Reichert, B.
    Windisch, G.