Automated planning through robust templates and multicriterial optimization for lung VMAT SBRT of lung lesions

被引:6
|
作者
Marrazzo, Livia [1 ]
Arilli, Chiara [1 ]
Pellegrini, Roberto [2 ]
Bonomo, Pierluigi [3 ]
Calusi, Silvia [4 ]
Talamonti, Cinzia [1 ,4 ]
Casati, Marta [1 ]
Compagnucci, Antonella [1 ]
Livi, Lorenzo [3 ,4 ]
Pallotta, Stefania [1 ,4 ]
机构
[1] Careggi Univ Hosp, Med Phys Unit, Florence, Italy
[2] Elekta AB, Stockholm, Sweden
[3] Careggi Univ Hosp, Radiotherapy Unit, Florence, Italy
[4] Univ Florence, Dept Expt & Clin Biomed Sci Mario Serio, Florence, Italy
来源
关键词
automated planning; lung SBRT; robust templates; VMAT; MODULATED ARC THERAPY; HYPOFRACTIONATED RADIOTHERAPY; PROSTATE-CANCER; GENERATION; COPLANAR;
D O I
10.1002/acm2.12872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop and validate a robust template for VMAT SBRT of lung lesions, using the multicriterial optimization (MCO) of a commercial treatment planning system. Methods The template was established and refined on 10 lung SBRT patients planned for 55 Gy/5 fr. To improve gradient and conformity a ring structure around the planning target volume (PTV) was set in the list of objectives. Ideal fluence optimization was conducted giving priority to organs at risk (OARs) and using the MCO, which further pushes OARs doses. Segmentation was conducted giving priority to PTV coverage. Two different templates were produced with different degrees of modulation, by setting the Fluence Smoothing parameter to Medium (MFS) and High (HFS). Each template was applied on 20 further patients. Automatic and manual plans were compared in terms of dosimetric parameters, delivery time, and complexity. Statistical significance of differences was evaluated using paired two-sided Wilcoxon signed-rank test. Results No statistically significant differences in PTV coverage and maximum dose were observed, while an improvement was observed in gradient and conformity. A general improvement in dose to OARs was seen, which resulted to be significant for chest wall V-30 Gy, total lung V-20 Gy, and spinal cord D-0.1 cc. MFS plans are characterized by a higher modulation and longer delivery time than manual plans. HFS plans have a modulation and a delivery time comparable to manual plans, but still present an advantage in terms of gradient. Conclusion The automation of the planning process for lung SBRT using robust templates and MCO was demonstrated to be feasible and more efficient.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [1] A novel approach to automatic planning: robust templates for lung VMAT SBRT
    Marrazzo, L.
    Arilli, C.
    Calusi, S.
    Casati, M.
    Talamonti, C.
    Bonomo, P.
    Livi, L.
    Pallotta, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S496 - S497
  • [2] Robust Planning for ITV-Based Lung VMAT SBRT
    Peca, S.
    Buczek, A.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E946 - E947
  • [3] On the validity of density overrides for VMAT lung SBRT planning
    Wiant, David
    Vanderstraeten, Caroline
    Maurer, Jacqueline
    Pursley, Jan
    Terrell, Jonathon
    Sintay, Benjamin J.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 104 - 118
  • [4] A Quantitative Approach to Analyze the Necessity of Robust Optimization for IMRT and VMAT Treatments of Lung SBRT
    Wang, Y.
    Zieminski, S.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E276 - E276
  • [5] Robust Optimization Strategies for Lung SBRT
    McCaw, T.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E150 - E150
  • [6] Frontiers in planning optimization for lung SBRT
    Giglioli, Francesca Romana
    Clemente, Stefania
    Esposito, Marco
    Fiandra, Christian
    Marino, Carmelo
    Russo, Serenella
    Strigari, Lidia
    Villaggi, Elena
    Stasi, Michele
    Mancosu, Pietro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 163 - 170
  • [7] Selection Strategy of Jaw Tracking in VMAT Planning for Lung SBRT
    Sun, Wuji
    Shi, Yinghua
    Li, Yu
    Ge, Chao
    Yang, Xu
    Xia, Wenming
    Chen, Kunzhi
    Wang, Libo
    Dong, Lihua
    Wang, Huidong
    [J]. FRONTIERS IN ONCOLOGY, 2022, 12
  • [8] Automated planning for lung SBRT: faster optimization without compromise on plan quality
    Goddeeris, B.
    Vanderstraeten, B.
    Vandecasteele, K.
    van Eijkeren, M.
    Derie, C.
    de Wagter, C.
    Lievens, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S593 - S594
  • [9] Four-Dimensional Treatment Planning for Lung VMAT-SBRT
    Hashimoto, M.
    Oohira, S.
    Ueda, Y.
    Miyazaki, M.
    Isono, M.
    Masaoka, A.
    Takashina, M.
    Koizumi, M.
    Teshima, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3434 - 3434
  • [10] Investigation of Dose Calculation Accuracy in VMAT Planning for SBRT Lung Treatment
    Rao, M.
    Wu, J.
    Cao, D.
    Ye, J.
    Chen, F.
    Wong, T.
    Mehta, V.
    Shepard, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S774 - S774