Comparison between 3D SPACE FLAIR and 3D TSE FLAIR in Meniere's disease

被引:8
|
作者
Bernaerts, Anja [1 ]
Janssen, Nick [1 ]
Wuyts, Floris L. [2 ,3 ]
Blaivie, Catherine [3 ]
Vanspauwen, Robby [3 ]
van Dinther, Joost [3 ]
Zarowski, Andrzej [3 ]
Offeciers, Erwin [3 ]
Deckers, Filip [1 ]
Casselman, Jan W. [1 ,4 ]
De Foer, Bert [1 ]
机构
[1] GZA Hosp Antwerp, Dept Radiol, Oosterveldlaan 24, B-2610 Antwerp, Belgium
[2] Univ Antwerp, Lab Equilibrium Invest & Aerosp, Univ Pl 1, B-2610 Antwerp, Belgium
[3] GZA Hosp Antwerp, European Inst ORL HNS, Oosterveldlaan 24, B-2610 Antwerp, Belgium
[4] Acad Hosp St Jan, Dept Radiol, Ruddershove 10, B-8000 Brugge, Belgium
关键词
Magnetic resonance imaging; Meniere disease; Endolymphatic hydrops; Perilymph; Diagnosis; CONCENTRATION GADOLINIUM CONTRAST; ENDOLYMPHATIC HYDROPS; SIGNAL INTENSITY; VISUALIZATION; SUBTRACTION; SEQUENCE; 3D-FLAIR;
D O I
10.1007/s00234-022-02913-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Heavily T2-weighted 3D FLAIR (hT(2)w-3D-FLAIR) sequence with constant flip angle (CFA) has been reported as being more sensitive to low concentrations of gadolinium (Gd) enabling endolymphatic hydrops (EH) visualization. The purpose of this study was to compare signal-to-noise (SNR) ratio, detection rate of EH, and increased perilymphatic enhancement (PE) as well as diagnostic accuracy in diagnosing definite Meniere's disease (MD), using 3D-SPACE FLAIR versus conventional 3D-TSE FLAIR. Methods This retrospective study included 29 definite MD patients who underwent a 4-h delayed intravenous (IV) Gd-enhanced 3D-TSE FLAIR and 3D-SPACE FLAIR MRI between February 2019 and February 2020. MR images were qualitatively and quantitatively analyzed twice by 2 experienced head and neck radiologists. Qualitative assessment included grading of cochlear and vestibular EH and visual comparison of PE. Quantitative assessment of PE was performed by placing a region of interest (ROI) and ratio calculation in the basal turn of the cochlea and the brainstem. Results The intra- and inter-reader reliability for grading of EH and PE was excellent (0.7 < kappa < 0.9) for 3D-SPACE FLAIR and exceeded the values for 3D-TSE FLAIR (0.5 < kappa < 0.9) The combination of EH and visual assessment of PE has the highest diagnostic accuracy in diagnosing definite MD on 3D-SPACE FLAIR with a sensitivity of 0.91 and a specificity of 0.98 resulting in a sensitivity raise of 6% compared to 3D-TSE FLAIR. Conclusion Four-hour delayed IV Gd-enhanced 3D-SPACE FLAIR sequence has a higher sensitivity and reproducibility than 3D-TSE FLAIR for the visualization of EH and increased PE in definite MD patients.
引用
收藏
页码:1011 / 1020
页数:10
相关论文
共 50 条
  • [21] 3D fast FLAIR: A CSF-nulled 3D fast spin-echo pulse sequence
    Barker, GJB
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (07) : 715 - 720
  • [22] Determination of Efficiency of 3D Fluid-Attenuated Inversion Recovery (FLAIR) in the Imaging of Multiple Sclerosis in Comparison With 2D FLAIR at 3-Tesla MRI
    Kummari, Satyanarayana
    Burra, Kiran Goud
    Reddy, Vudem Ranjith Kumar
    Das, Saraswata
    Anilkumar, Challa
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [23] Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T
    Eliezer, Michael
    Vaussy, Alexis
    Toupin, Solenn
    Barbe, Remy
    Kannengiesser, Stephan
    Stemmer, Alto
    Houdart, Emmanuel
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 13 - 20
  • [24] FLAIR序列的血管高信号无法在3D CUBE FLAIR序列上显示
    J.Hodel
    X.Leclerc
    M.Rodallec
    S.Gerber
    R.Blanc
    O.Outteryck
    张泳欣
    [J]. 国际医学放射学杂志, 2013, (05) : 496 - 496
  • [25] Comparison of 3D Double Inversion Recovery (DIR) versus 3D Fluid Attenuated Inversion Recovery (FLAIR) in precise diagnosis of acute optic neuritis
    Murumkar, Vivek
    Baishya, Priyanka Priyadarshini
    Kulanthaivelu, Karthik
    Saini, Jitender
    Manjunath, Netravathi
    Gupta, Rakesh Kumar
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155
  • [26] Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results
    Bink, A
    Schmitt, M
    Gaa, J
    Mugler, JP
    Lanfermann, H
    Zanella, FE
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (05) : 1104 - 1110
  • [27] Optimized 3D-FLAIR sequences to shorten the delay between intravenous administration of gadolinium and MRI acquisition in patients with Meniere's disease
    Barlet, Juliette
    Vaussy, Alexis
    Ejzenberg, Yohan
    Toupet, Michel
    Hautefort, Charlotte
    Gillibert, Andre
    Attye, Arnaud
    Eliezer, Michael
    [J]. EUROPEAN RADIOLOGY, 2022, 32 (10) : 6900 - 6909
  • [28] Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results
    Andrea Bink
    Melanie Schmitt
    Jochen Gaa
    John P. Mugler
    Heinrich Lanfermann
    Friedhelm E. Zanella
    [J]. European Radiology, 2006, 16 : 1104 - 1110
  • [29] Iterative Denoising Accelerated 3D FLAIR Sequence for Hydrops MR Imaging at 3T
    Quint, R.
    Vaussy, A.
    Stemmer, A.
    Hautefort, C.
    Houdart, E.
    Eliezer, M.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (09) : 1064 - 1069
  • [30] Endolymphatic Duct Blockage for Meniere's Disease Using the 3D Exoscope
    Nader, Marc-Elie
    Gidley, Paul W.
    Saliba, Issam
    [J]. OTOLOGY & NEUROTOLOGY, 2023, 44 (05) : E362 - E362