Development of Suitable Test Methods for the Screw Connections in Cold-Formed Steel Roof Battens

被引:13
|
作者
Sivapathasundaram, Mayooran [1 ]
Mahendran, Mahen [1 ]
机构
[1] Queensland Univ Technol, Brisbane, Qld 4000, Australia
基金
澳大利亚研究理事会;
关键词
Cold-formed steel structures; Light-gauge steel roofing systems; Steel roof battens; Pull-through failures; Test methods; Experimental study; Metal and composite structures; CLADDINGS; BEHAVIOR; SUBJECT; DESIGN;
D O I
10.1061/(ASCE)ST.1943-541X.0001476
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The roofing systems of low-rise buildings are commonly made of thin, high-strength steel roof sheeting and battens. These light-gauge steel roofing systems are subjected to high-wind uplift loads during tropical cyclones and thunderstorms. In recent times, roof batten-to-rafter or truss connection failures have been identified as a major cause of severe roof failures during high-wind events. Most of these connection failures are in the form of localized pull-through failures of the bottom flanges of steel roof battens at their screw connections. The design practice at present is based on expensive and time-consuming full-scale tests or inappropriate small-scale tests. Hence, there is an urgent need to develop suitable test methods to determine the pull-through capacity of roof battens. This paper presents the details of an experimental study undertaken to investigate pull-through failures of light-gauge steel roof battens using both full-scale and small-scale tests. The investigation showed that the design capacity equations and test methods given in current cold-formed steel design standards for single-screw connections cannot be used for roof batten pull-through failures. This paper recommends suitable small-scale test methods and associated calculation methods to determine the pull-through capacities of roof battens. (C) 2016 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Structural Behavior of Screwed Connections in Cold-Formed Steel Beams
    Minh Toan Huynh
    Cao Hung Pham
    Rogers, Cohn A.
    Hancoc, Gregory J.
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (03)
  • [42] Structural behavior of cold-formed stainless steel bolted connections
    Cai, Yancheng
    Young, Ben
    THIN-WALLED STRUCTURES, 2014, 83 : 147 - 156
  • [43] Structural performance of cold-formed steel structures with bolted connections
    Chung, KF
    ADVANCES IN STRUCTURAL ENGINEERING, 2005, 8 (03) : 231 - 245
  • [44] Serviceability limit state for cold-formed steel bolted connections
    LaBoube, RA
    Yu, WW
    Carril, JL
    CONNECTIONS IN STEEL STRUCTURES III: BEHAVIOUR, STRENGTH AND DESIGN, 1996, : 403 - 411
  • [45] New design provisions for cold-formed steel bolted connections
    LaBoube, RA
    Yu, WW
    LIGHT-WEIGHT STEEL AND ALUMINIUM STRUCTURES, 1999, : 569 - 576
  • [46] Base connections of single cold-formed steel portal frames
    Dundu, M.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 78 : 38 - 44
  • [47] An experimental study into the capacity of cold-formed steel truss connections
    Zeynalian, Mehran
    Shelley, Adele
    Ronagh, H. R.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 127 : 176 - 186
  • [48] Behavior of low ductility steels in cold-formed steel connections
    Cairo Univ, Fayoum, Egypt
    Thin-Walled Struct, 2 (135-151):
  • [49] BEHAVIOUR AND CAPACITY OF COLD-FORMED STEEL BOLTED MOMENT CONNECTIONS
    Mojtabaei, Seyed Mohammad
    Becque, Jurgen
    Hajirasouliha, Iman
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 628 - 638
  • [50] Experiments and finite element modelling of screw pattern of self-drilling screw connections for high strength cold-formed steel
    Roy, Krishanu
    Lau, Hieng Ho
    Tina Chui Huon Ting
    Masood, Rehan
    Kumar, Ankur
    Lim, James B. P.