Dual-source CT in step-and-shoot mode: Noninvasive coronary angiography with low radiation dose

被引:203
|
作者
Stolzmann, Paul [1 ]
Leschka, Sebastian [1 ]
Scheffel, Hans [1 ]
Krauss, Tobias [1 ]
Desbiolles, Lotus [1 ]
Plass, Andre [2 ]
Genoni, Michele [2 ]
Flohr, Thomas G. [3 ]
Wildermuth, Simon [4 ]
Marincek, Borut [1 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Siemens Med Solut, Comp Tomog CTE PA, Forchheim, Germany
[4] Kantonsspital St Gallen, Inst Radiol, St Gallen, Switzerland
基金
瑞士国家科学基金会;
关键词
D O I
10.1148/radiol.2483072032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively investigate computed tomographic (CT) image quality parameters by using different protocols and to calculate radiation dose estimates for noninvasive coronary angiography performed with dual-source CT in the step-and-shoot (SAS) mode. Materials and Methods: This study was local ethics board approved; written informed consent was obtained from all patients. In the preliminary portion of the study, 40 patients underwent CT coronary angiography in the SAS mode: at 100 kV (protocol A) in 22 patients with a body mass index (BMI) of less than 25 kg/m(2) and at 120 kV (protocol B) in 18 patients with a BMI of 25-30 kg/m(2). Both protocols involved use of an attenuation-based tube current and 1 mL of contrast material per kilogram of body weight. The final portion of the study involved 50 additional patients: 21 patients with a BMI of 25-30 kg/cm(2) assigned to protocol B and 29 patients with a BMI of less than 25 kg/cm(2) assigned to protocol C, which was performed with 100 kV, an attenuation-based tube current, and a reduced contrast material dose of 0.8 mL/kg. Image quality was independently assessed. Attenuation in the aorta and coronary arteries and image noise were measured. Radiation dose was estimated. Results: Mean image noise was similar with protocols A and B. Mean attenuation in the aorta and coronary arteries with protocol A (444 HU) was significantly (P < .001) higher than that with protocol B (358 HU). The reduced contrast material dose in protocol C yielded attenuation similar to that with protocol B. Diagnostic image quality was achieved with all protocols in 1237 (97.9%) of 1264 coronary segments. No significant differences in image quality between the 100- and 120-kV protocols were found. Mean heart rate had a significant effect on motion artifacts (area under receiver operating characteristic curve [AUC] = 0.818; 95% confidence interval [CI]: 0.723, 0.892; P < .001), whereas heart rate variability had a significant effect on stair-step artifacts (AUC = 0.79; 95% CI: 0.687, 0.865; P < .001). The mean estimated effective dose was 1.2 mSv +/- 0.2 for protocols A and C and 2.6 mSv +/- 0.5 for protocol B. Conclusion: Dual-source SAS-mode CT coronary angiography yielded diagnostic image quality for 97.9% of coronary segments at a low radiation dose. (C) RSNA, 2008.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 50 条
  • [41] Coronary CT angiography with low radiation dose
    Lei Xu
    Zhaoqi Zhang
    [J]. The International Journal of Cardiovascular Imaging, 2010, 26 : 17 - 25
  • [42] Coronary CT angiography with low radiation dose
    Xu, Lei
    Zhang, Zhaoqi
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 17 - 25
  • [43] Diagnostic accuracy of dual-source CT angiography and coronary risk stratification
    Yang, Xia
    Gai, Lu-yue
    Li, Ping
    Chen, Yun-dai
    Li, Tao
    Yang, Li
    [J]. VASCULAR HEALTH AND RISK MANAGEMENT, 2010, 6 : 935 - 941
  • [44] Comparison of myocardial bridging by dual-source CT with conventional coronary angiography
    Lu, Guang-Ming
    Zhang, Long-Jiang
    Guo, Hua
    Huang, Wei
    Merges, Reto D.
    [J]. CIRCULATION JOURNAL, 2008, 72 (07) : 1079 - 1085
  • [45] Application of double low dose combined low flow injection in coronary dual-source coronary computed tomography angiography
    Tang, Zhenhua
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (09): : 1442 - 1447
  • [46] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Lembcke, Alexander
    Schwenke, Carsten
    Hein, Patrick A.
    Knobloch, Gesine
    Durmus, Tahir
    Hamm, Bernd
    Huppertz, Alexander
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (01) : 120 - 127
  • [47] Systolic reconstruction in patients with low heart rate using coronary dual-source CT angiography
    Okada, Munemasa
    Nakashima, Yoshiteru
    Shigemoto, Youko
    Matsunaga, Naofumi
    Miura, Toshiro
    Nao, Tomoko
    Sano, Yuichi
    Narazaki, Akiko
    Kido, Shoji
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 336 - 341
  • [48] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Alexander Lembcke
    Carsten Schwenke
    Patrick A. Hein
    Gesine Knobloch
    Tahir Durmus
    Bernd Hamm
    Alexander Huppertz
    [J]. European Radiology, 2014, 24 : 120 - 127
  • [49] Ultra-low dose one-step CT angiography for coronary, carotid and cerebral arteries using 128-slice dual-source CT: A feasibility study
    Zhao, Lei
    Bao, Jiaqi
    Guo, Youmin
    Li, Jianbo
    Yang, Xiaoguang
    Lv, Tiegang
    Hao, Fen'e
    Wang, Zefeng
    Yang, Zhenxing
    Liu, Aishi
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 17 (05) : 4167 - 4175
  • [50] Comprehensive low-dose imaging of carotid and coronary arteries with a single-injection dual-source CT angiography protocol
    Tognolini, A.
    Arellano, C. S.
    Marfori, W.
    Heidari, G.
    Sayre, J. W.
    Krishnam, M. S.
    Ruehm, S. G.
    [J]. CLINICAL RADIOLOGY, 2014, 69 (03) : 246 - 253