Behaviour of the Purkinje system during defibrillation-strength shocks

被引:4
|
作者
Boyle, Patrick M. [1 ]
Deo, Makarand [1 ]
Vigmond, Edward J. [1 ]
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
关键词
D O I
10.1109/IEMBS.2007.4352313
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During normal sinus rhythm, orderly activation of the heart is facilitated by a specialized network of fibres lining the ventricles called the Purkinje system (PS). Characteristic features of the PS encourage coordinated depolarization of spatially disparate endocardial sites. Although the basic role A the PS is well understood, many questions regarding its behaviour, especially during the process of defibrillation, remain unanswered. Purkinje fibres react differently during large electrical shocks than the myocardium on which they run because they are oriented in different directions than the endocardial fibres, they possess distinct electrophysiology, and they are part of a system that is one-dimensional in nature. Because,if the small size of Purkinje fibres and their positioning on the endocardium, in vivo observation of PS-related phenomena remains problematic. Therefore, computer modelling offers a unique opportunity to investigate the role of the PS during defibrillation. In this paper, the effects of defibrillation-strength shocks on a finite element model of the ventricles coupled to a distinct PS are ascertained. Results indicate that the presence of the PS has a profound impact on the course of activation in the ventricles. During shocks, depolarizations are elicited at bends and bifurcations in the PS. Subsequently, this activity spreads throughout the PS in all directions, creating numerous regions of myocardial depolarization and accelerating the excitation A the whole structure. These excitations are explained by the cable-like nature of Purkinje fibres, which exposes them to vastly different electrical field effects than bulk myocardium. due to abrupt conductivity tensor changes. Depending on electrode orientation and the depth of fibre penetration into the endocardium, this phenomenon can bring about a significant abbreviation of the total activation time for a particular shock when compared to simulations where the PS is not included. For a medium-strength shock oriented along the main axis of the heart, the PS produced a 30% reduction in activation time. In conclusion, the PS is of fundamental importance for determining defibrillation shock response.
引用
收藏
页码:419 / 422
页数:4
相关论文
共 50 条
  • [31] Implantable vagus nerve stimulation system performance is not affected by internal or external defibrillation shocks
    Libbus, Imad
    Stubbs, Scott R.
    Mazar, Scott T.
    Mindrebo, Scott
    KenKnight, Bruce H.
    DiCarlo, Lorenzo A.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 63 (03) : 555 - 560
  • [32] Implantable vagus nerve stimulation system performance is not affected by internal or external defibrillation shocks
    Imad Libbus
    Scott R. Stubbs
    Scott T. Mazar
    Scott Mindrebo
    Bruce H. KenKnight
    Lorenzo A. DiCarlo
    Journal of Interventional Cardiac Electrophysiology, 2022, 63 : 555 - 560
  • [33] CARDIAC POTENTIAL GRADIENT FIELDS GENERATED BY SINGLE, COMBINED, AND SEQUENTIAL SHOCKS DURING VENTRICULAR DEFIBRILLATION
    WHARTON, JM
    WOLF, PD
    IDEKER, RE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 406 - 406
  • [34] Virtual electrode induced transmural and midmyocardial scroll-waves during internal defibrillation shocks
    Cheng, Y
    Nikolski, V
    Efimov, IR
    CIRCULATION, 2000, 102 (18) : 340 - 341
  • [35] Computer modelling of transthoracic electric field during defibrillation shocks: An efficient finite difference implementation
    Malik, M
    Smits, KFAA
    Lindemans, F
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 255 - 258
  • [36] Leakage of energy to the body surface during defibrillation shock by an implantable cardioverter-defibrillator (TCD) system - Experimental evaluation during defibrillation shocks through the right ventricular lead and the subcutaneous active-can in canines
    Niwano, S
    Kitano, Y
    Moriguchi, M
    Yoshizawa, N
    Kashiwa, T
    Suyama, M
    Toyoshima, T
    Izumi, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2001, 65 (03): : 219 - 225
  • [37] Nonlinear changes of transmembrane potential during defibrillation shocks -: Role of Ca2+ current
    Cheek, ER
    Ideker, RE
    Fast, VG
    CIRCULATION RESEARCH, 2000, 87 (06) : 453 - 459
  • [38] Transthoracic Impedance During Real Cardiac Arrest Defibrillation Attempts: Are Stacked-Shocks Appropriate?
    Niles, Dana E.
    Sutton, Robert M.
    Brunner, Sara
    Stavland, Mette
    Meaeny, Peter
    Nishisaki, Akira
    Arbogast, Kristy
    Maltese, Matthew
    Donoghue, Aaron
    Devale, Sujatha
    Berg, Robert A.
    Nadkarni, Vinay
    CIRCULATION, 2009, 120 (18) : S1458 - S1458
  • [39] TB dynamic behaviour during thermal shocks - simulation and experiment
    Vesely, Z
    Kunes, J
    Honner, M
    Martan, J
    ADVANCED COMPUTATIONAL METHODS IN HEAT TRANSER VII, 2002, 4 : 503 - 512
  • [40] Synchronization of atrial defibrillation shocks to ventricular paced beats during heart rate deceleration improves safety
    Krum, D
    Hare, J
    Mughal, K
    Dhala, A
    Sra, J
    Akhtar, M
    Jazayeri, MR
    CIRCULATION, 1997, 96 (08) : 1148 - 1148