Estimation of the spatial mean and peak flow velocities rising real-time 3D color Doppler echocardiography: In vitro and in vivo studies

被引:4
|
作者
Tsujino, H [1 ]
Jones, M [1 ]
Shiota, T [1 ]
Qin, JX [1 ]
Cardon, LA [1 ]
Morehead, AJ [1 ]
Travaglini, A [1 ]
Bauer, F [1 ]
Zetts, AD [1 ]
Greenberg, NL [1 ]
Panza, J [1 ]
Thomas, JD [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiol, Cardiovasc Imaging Ctr, Cleveland, OH 44195 USA
来源
关键词
D O I
10.1109/CIC.1999.825934
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Using real-time, three-dimensional (3D) color Doppler, experimental studies were performed to quantify velocity in the out flow tract from cross-sectional, short mis images. In vitro experiments showed an excellent linear correlation between the reference pulsed wave (PW) Doppler and 3D color estimates of the peak velocities (r = 0.98). In an animal experiment, 3D peak flow velocities showed a reasonably good agreement with reference peak velocities by PW Doppler (r = 0.76, delta = +11.6 %). The spatial mean velocity by 3D showed a good linear relationship with PW peak velocity, but with an anticipated underestimation (r = 0.81, delta = -43 %) due to the non-uniform velocity profile. Real-time, color 3D echocardiography was capable of quantifying velocities accurately, permitting the calculation of flow volume without any geometrical assumptions about flow distribution.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 50 条
  • [41] Application of colour coded tissue Doppler imaging and real-time 3D echocardiography in the quantification of mechanical intraventricular dyssynchrony
    Liodakis, E
    Al Sharef, O
    Dawson, D
    Nihoyannopoulos, P
    HEART, 2006, 92 : I40 - I40
  • [42] Relation of left atrial maximal volume measured by real-time 3D echocardiography to demographic, clinical, and Doppler variables
    De Castro, Stefano
    Caselli, Stefano
    Di'Angelantonio, Ernanuele
    Del Colle, Sara
    Mirabelli, Francesca
    Marcantonio, Andrea
    Puccio, Danilo
    Santini, Daria
    Pandian, Natesa G.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (09): : 1347 - 1352
  • [43] Dysynchrony is in the eye of the beholder: A comparison of real-time 3D echocardiography and tissue Doppler for identifying and locating mechanical delay
    Burgess, MI
    Chan, J
    Jenkins, C
    Marwick, TH
    CIRCULATION, 2005, 112 (17) : U601 - U601
  • [44] Real-time Highway Traffic Flow Estimation based on 3D Markov Random Field
    Ahn, Jinyoung
    Ko, Eunjeong
    Kim, Eun Yi
    2014 IEEE 17TH INTERNATIONAL CONFERENCE ON INTELLIGENT TRANSPORTATION SYSTEMS (ITSC), 2014, : 308 - 313
  • [45] Real-time 3D LiDAR Flow for Autonomous Vehicles
    Baur, Stefan A.
    Moosmann, Frank
    Wirges, Sascha
    Rist, Christoph B.
    2019 30TH IEEE INTELLIGENT VEHICLES SYMPOSIUM (IV19), 2019, : 1288 - 1295
  • [46] Real-Time 3D Fusion Echocardiography (vol 3, pg 682, 2010)
    Szmigielski, C.
    Rajpoot, K.
    Grau, V
    Myerson, S. G.
    Holloway, C.
    Noble, J. A.
    Kerber, R.
    Becher, H.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (03) : 314 - 314
  • [47] Role of real-time transthoracic 3D echocardiography in the assessment of mechanical asynchrony
    Liodakis, E
    Al Shareef, O
    Dawson, D
    Pearson, P
    Nihoyannopoulos, P
    HEART, 2005, 91 : A31 - A31
  • [48] Real-time 3D echocardiography for estimation of severity in valvular heart disease. Impact on current guidelines
    Buck, T.
    Boesche, L.
    Plicht, B.
    HERZ, 2017, 42 (03) : 241 - 254
  • [49] GEOMETRIC DIFFERENCES IN MITRAL APPARATUS BETWEEN DIFFERENT TYPES OF ISCHEMIC MITRAL REGURGITANT JET: A COLOR DOPPLER REAL-TIME 3D TRANSESOPHAGEAL ECHOCARDIOGRAPHY STUDY
    Izumo, Masaki
    Kuwahara, Eiji
    Saitoh, Takeji
    Tanaka, Jun
    Fukuoka, Yoko
    Gurudevan, Swaminatha V.
    Siegel, Robert J.
    Shiota, Takahiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1933 - E1933
  • [50] Anatomy of Right Atrial Structures by Real-Time 3D Transesophageal Echocardiography
    Faletra, Francesco F.
    Ho, Siew Y.
    Auricchio, Angelo
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (09) : 966 - 975