Estimation of the spatial mean and peak flow velocities rising real-time 3D color Doppler echocardiography: In vitro and in vivo studies

被引:4
|
作者
Tsujino, H [1 ]
Jones, M [1 ]
Shiota, T [1 ]
Qin, JX [1 ]
Cardon, LA [1 ]
Morehead, AJ [1 ]
Travaglini, A [1 ]
Bauer, F [1 ]
Zetts, AD [1 ]
Greenberg, NL [1 ]
Panza, J [1 ]
Thomas, JD [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiol, Cardiovasc Imaging Ctr, Cleveland, OH 44195 USA
来源
关键词
D O I
10.1109/CIC.1999.825934
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Using real-time, three-dimensional (3D) color Doppler, experimental studies were performed to quantify velocity in the out flow tract from cross-sectional, short mis images. In vitro experiments showed an excellent linear correlation between the reference pulsed wave (PW) Doppler and 3D color estimates of the peak velocities (r = 0.98). In an animal experiment, 3D peak flow velocities showed a reasonably good agreement with reference peak velocities by PW Doppler (r = 0.76, delta = +11.6 %). The spatial mean velocity by 3D showed a good linear relationship with PW peak velocity, but with an anticipated underestimation (r = 0.81, delta = -43 %) due to the non-uniform velocity profile. Real-time, color 3D echocardiography was capable of quantifying velocities accurately, permitting the calculation of flow volume without any geometrical assumptions about flow distribution.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 50 条
  • [1] Estimation of the spatial yean and peak flow velocities using real-time 3D (RT3D) color Doppler echocardiography: An in vitro experiment
    Tsujino, H
    Shiota, T
    Qin, JX
    Bauer, F
    Travaglini, A
    Greenberg, NL
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 436A - 436A
  • [2] Left ventricular inflow propogation determined by real-time 3D color Doppler echocardiography
    Bauer, F
    Shiota, T
    Sitges, M
    Qin, JX
    Kim, YJ
    Tsujino, H
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 408A - 408A
  • [3] Dealiasing of mitral regurgitant color Doppler flow: A novel approach for direct flow quantification at the vena contracta based on real-time 3D color Doppler echocardiography
    Plicht, Bjoern
    Goldwasser, Ranny
    Kahlert, Philipp
    Buck, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 103A - 103A
  • [4] Real-time 3D color flow Doppler for guidance of vibrating interventional devices
    Fronheiser, MP
    Wolf, PD
    Idriss, SF
    Nelson, RC
    Lee, W
    Smith, SW
    ULTRASONIC IMAGING, 2004, 26 (03) : 173 - 184
  • [5] Quantification of the volumetric flow rate using real-time 3D (RT3D) color Doppler echocardiography: An animal study
    Tsujino, H
    Jones, M
    Shiota, T
    Qin, JX
    Cardon, LA
    Morehead, AJ
    Zetts, AD
    Bauer, F
    Travaglini, A
    Greenberg, NL
    Panza, JA
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 461A - 462A
  • [6] Quantitative digital color Doppler and real-time 3D echocardiography for evaluating aortic and mitral regurgitation
    Tsujino, Hiroyuki, 2000, Elsevier Science Ltd, Exeter, United Kingdom (26):
  • [7] Impact of temporal resolution on flow quantification by real-time 3D color Doppler echocardiography: Numerical modeling and animal validation study
    Tsujino, H
    Jones, M
    Shiota, T
    Qin, JX
    Cardon, LA
    Morehead, AJ
    Zetts, AD
    Bauer, F
    Sitges, M
    Hang, X
    Greenberg, NL
    Panza, JA
    Thomas, JD
    COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 : 761 - 764
  • [8] Real-time 3D transesophageal echocardiography
    Pua, EC
    Idriss, SF
    Wolf, PD
    Smith, SW
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 778 - 781
  • [9] Real-time 3D transesophageal echocardiography
    Pua, EC
    Idriss, SF
    Wolf, PD
    Smith, SW
    ULTRASONIC IMAGING, 2004, 26 (04) : 217 - 232
  • [10] Real-Time 3D Fusion Echocardiography
    Szmigielski, Cezary
    Rajpoot, Kashif
    Grau, Vicente
    Myerson, Saul G.
    Holloway, Cameron
    Noble, J. Alison
    Kerber, Richard
    Becher, Harald
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (07) : 682 - 690