Modeling and Resonance Damping for the CM Loop of the MLCL-Filtered Grid-Connected Inverter With Variable Inductors Under the Weak Grid Condition

被引:6
|
作者
Zhang, Jiansong [1 ]
Yang, Xu [1 ]
Chen, Wenjie [1 ]
Zhou, Hongwei [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Inverters; Damping; Inductors; Power harmonic filters; Capacitors; Inductance; Resonant frequency; Common mode resonance (CMR); damping; modified LCL (MLCL); variable inductor; LEAKAGE CURRENT; VOLTAGE; COMMON; MODULATION; CONVERTERS; DESIGN; FEEDFORWARD; REALIZATION; REDUCTION; DRIVE;
D O I
10.1109/JESTPE.2021.3050791
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The modified LCL (MLCL) is commonly applied in photovoltaic (PV) string inverters to suppress the leakage current and enhance the electromagnetic interference (EMI) performance of the grid current. However, the potential risk of resonance appears in the common mode (CM) loop, which was caused by the MLCL filter. In this article, the CM model of the inverter is first built considering the inductance saturation. It is found that the variable inductor brings phase margin decreasing problem and additional resonance points in the CM loop. To suppress the CM resonance (CMR), novel passive and active damping strategies are explored in this article. The improved passive damping (IPD) strategy is realized by introducing a paralleled RC unit, which greatly reduces the damping resistor losses without affecting the damping performance. Besides, a novel active damping (NAD) strategy is proposed to compensate the time delay and to raise the phase margin. Moreover, considering the gradient mutation issue brought by the discontinuous pulsewidth modulation (DPWM) scheme, an antisaturation PWM (ASPWM) scheme is applied to eliminate the oscillation. Finally, experiments are conducted on an 80-kW PV string inverter. After applying the proposed CMR damping strategy with the ASPWM scheme, CMR is fully eliminated in the whole power range despite the grid condition.
引用
收藏
页码:310 / 323
页数:14
相关论文
共 50 条
  • [31] Grid-connected Inverter Control Strategy for Eliminating the Influence of Phase-locked Loop in Weak Grid
    Zhao, Yiting
    Du, Xiong
    Liu, Junliang
    Tan, Shangning
    2020 IEEE 9TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC2020-ECCE ASIA), 2020, : 1633 - 1639
  • [32] A Global Robust Output Regulation Method for Grid-Connected Inverter with LCL Filter in Weak Grid Condition
    Lin, Pengfeng
    Zhang, Chuanlin
    Wang, Peng
    Li, Xiaoqiang
    Xiao, Jianfang
    Tu, Pengfei
    Hoong, Choo Fook
    PROCEEDINGS OF THE 2017 12TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2017, : 1646 - 1651
  • [33] Improving Small-Signal Stability of Grid-Connected Inverter Under Weak Grid by Decoupling Phase-Lock Loop and Grid Impedance
    Lin, Xianfu
    Yu, Jingrong
    Yu, Ruoxue
    Zhang, Junhao
    Yan, Zhongzong
    Wen, He
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (07) : 7040 - 7053
  • [34] A Novel FLL for Single-Phase Grid-Connected PV Inverter Under Weak Grid
    Liu, Guihua
    Zhu, Jianing
    Zhou, Hang
    Wang, Wenxiu
    Wang, Wei
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 3353 - 3358
  • [35] Adaptive Control Method for Improving Current Quality of Grid-connected Inverter Under Weak Grid
    Ma X.
    Xu R.
    Chen M.
    Fu A.
    Yang S.
    Dianwang Jishu/Power System Technology, 2019, 43 (08): : 2892 - 2900
  • [36] Dynamic Stability Study of Grid-Connected Inverter Based on Virtual Synchronizer under Weak Grid
    Li, Yinghui
    Chen, Jianan
    Wang, Xiaohuan
    Zhang, Xudong
    Zhao, Xiaojun
    ENERGIES, 2022, 15 (19)
  • [37] PQ-U Control Method of Grid-Connected PV Inverter under Weak Grid
    Liu Guihua
    Guo Lei
    Tao Hailiang
    Zhu Xiaohui
    Wang Wei
    2017 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ASIA-PACIFIC (ITEC ASIA-PACIFIC), 2017, : 747 - 752
  • [38] State feedback control for single-phase grid-connected inverter under weak grid
    Jiao, Jiao
    Hung, John Y.
    Nelms, R. M.
    2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2017, : 879 - 885
  • [39] Control strategy of an LCL type grid-connected inverter with the influence of a phase-locked loop under a weak power grid
    Liu R.
    Chen Z.
    Tang W.
    Zhu J.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (05): : 178 - 187
  • [40] Robust Grid-Current-Feedback Resonance Suppression Method for LCL-Type Grid-Connected Inverter Connected to Weak Grid
    Zhou, Xiaoping
    Zhou, Leming
    Chen, Yandong
    Shuai, Zhikang
    Guerrero, Josep M.
    Luo, An
    Wu, Wenhua
    Yang, Ling
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) : 2126 - 2137