Non-contact refractive index measurement based on fiber optic beam-through technique

被引:0
|
作者
Rahman, H. A. [1 ,2 ,4 ]
Harun, S. W. [1 ,2 ]
Yasin, M. [2 ,3 ]
Ahmad, H. [2 ]
机构
[1] Univ Malaya, Fac Engn, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Sci, Dept Phys, Photon Res Ctr, Kuala Lumpur 50603, Malaysia
[3] Airlangga Univ, Fac Sci & Technol, Dept Phys, Surabaya 60115, Indonesia
[4] Univ Teknol MARA UiTM, Fac Elect Engn, Shah Alam 40450, Malaysia
关键词
Fiber optic; Fiber optic displacement sensor; Refractive index measurement; Beam-through technique; Sodium chloride in de-ionized water; DISPLACEMENT SENSOR; ALCOHOL DETECTION;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A simple refractive index sensor for various concentrations of sodium chloride (NaCl) in de-ionized water is proposed and demonstrated. The beam-through technique is used to obtain output voltage of liquids with known refractive indices, namely methanol, de-ionized water, acetone and ethanol. Based on the output voltage of these liquids, the sensor characteristic curve is determined and the refractive indices of 2 % to 12 % sodium chloride concentrations are obtained. A sensitivity and detection limit of 23.07 mV/refractive index unit (RIU) and 2.28 x 10(-3) RIU have been derived from measurements, respectively, with a linearity of more than 97 %. The fiber optic sensor is a promising alternative to other well-established methods for the measurement of liquid refractive index due to its simplicity of design, linearity, non-contact sensing, ruggedness and low fabrication cost.
引用
收藏
页码:1035 / 1038
页数:4
相关论文
共 50 条
  • [41] Miniature non-contact photoacoustic probe based on fiber-optic photoacoustic remote sensing microscopy
    Zhou, Jiasheng
    Zhou, Jingying
    Wang, Wei
    Liang, Siqi
    Jing, Lili
    Bo, Shou-Hang
    Chen, Sung-Liang
    OPTICS LETTERS, 2021, 46 (22) : 5767 - 5770
  • [42] Non-Contact Measurement Method Research Based on HoloLens
    Huang Jing
    Yang Boxiong
    Chen Jiajie
    2017 INTERNATIONAL CONFERENCE ON VIRTUAL REALITY AND VISUALIZATION (ICVRV 2017), 2017, : 267 - 271
  • [43] Optical fiber diameter non-contact measurement with computer image processing
    2000, J Zhongshan Univ, Guangzhou, China (39):
  • [44] Neural network based non-contact measurement system
    Zhou, LM
    Waheed, A
    Lu, BH
    AUTOMATED OPTICAL INSPECTION FOR INDUSTRY, 1996, 2899 : 500 - 507
  • [45] Non-Contact Measurement Device based on Ultrasonic Technology
    Lan, Zhenping
    Meng, Huimin
    Li, Jintao
    Wang, Yuru
    Li, Ping
    Jin, Jiyu
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 2654 - 2657
  • [46] Surface plasmon resonance based fiber optic refractive index sensors
    Hlubina, Petr
    Kadulova, Miroslava
    Ciprian, Dalibor
    19TH POLISH-SLOVAK-CZECH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2014, 9441
  • [47] Fiber Optic-Based Refractive Index Sensing at INESC Porto
    Jorge, Pedro A. S.
    Silva, Susana O.
    Gouveia, Carlos
    Tafulo, Paula
    Coelho, Luis
    Caldas, Paulo
    Viegas, Diana
    Rego, Gaspar
    Baptista, Jose M.
    Santos, Jose L.
    Frazao, Orlando
    SENSORS, 2012, 12 (06): : 8371 - 8389
  • [48] Non-contact method based on intensity modulation of light for measurement of vibration of a thin cantilever beam
    Roy, Ram Kishore
    Bezboruah, Tulshi
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (05) : 746 - 754
  • [49] Non-contact measurement method of beam vibration with laser stripe tracking based on tilt photography
    Wu, Tong
    Tang, Liang
    Du, Peng
    Liu, Nian
    Zhou, Zhixiang
    Qi, Xiaolei
    MEASUREMENT, 2022, 187
  • [50] Simple confocal thickness gauge based on fibre-optic confocal sensor for non-contact measurement
    Kim, D. -H.
    Ilev, I. K.