Investigating in vivo airway wall mechanics during tidal breathing with optical coherence tomography

被引:15
|
作者
Robertson, Claire [1 ,2 ]
Lee, Sang-Won [3 ,4 ]
Ahn, Yeh-Chan [3 ,5 ]
Mahon, Sari [3 ]
Chen, Zhongping [1 ,2 ,3 ]
Brenner, Matthew [3 ,6 ]
George, Steven C. [1 ,2 ,7 ]
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Edwards Lifesci Ctr Adv Cardiovasc Technol, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[4] Elect & Telecommun Res Inst, Taejon 305700, South Korea
[5] Pukyong Natl Univ, Dept Biomed Engn, Pusan 608737, South Korea
[6] Univ Calif Irvine, Div Pulm & Crit Care, Orange, CA 92868 USA
[7] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92697 USA
关键词
airway compliance; mechanics; in vivo; optical coherence tomography; ULTRASONIC PALPATION; ELASTOGRAPHY; ASTHMA; OCT; DEFORMATION; DYNAMICS; STRAIN; LUNG;
D O I
10.1117/1.3642006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) is a nondestructive imaging technique offering high temporal and spatial resolution, which makes it a natural choice for assessing tissue mechanical properties. We have developed methods to mechanically analyze the compliance of the rabbit trachea in vivo using tissue deformations induced by tidal breathing, offering a unique tool to assess the behavior of the airways during their normal function. Four-hundred images were acquired during tidal breathing with a custom-built endoscopic OCT system. The surface of the tissue was extracted from a set of these images via image processing algorithms, filtered with a bandpass filter set at respiration frequency to remove cardiac and probe motion, and compared to ventilatory pressure to calculate wall compliance. These algorithms were tested on elastic phantoms to establish reliability and reproducibility. The mean tracheal wall compliance (in five animals) was 1.3 +/- 0.3x10(-5) (mm Pa)(-1). Unlike previous work evaluating airway mechanics, this new method is applicable in vivo, noncontact, and loads the trachea in a physiological manner. The technique may have applications in assessing airway mechanics in diseases such as asthma that are characterized by significant airway remodeling. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3642006]
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Visualization and Validation of The Microstructures in The Airway Wall in vivo Using Diffractive Optical Coherence Tomography
    Thiboutot, Jeffrey
    Yuan, Wu
    Park, Hyeon-cheol
    Li, Dawei
    Loube, Jeffrey
    Mitzner, Wayne
    Yarmus, Lonny
    Li, Xingde
    Brown, Robert H.
    ACADEMIC RADIOLOGY, 2022, 29 (11) : 1623 - 1630
  • [2] Airway wall thickness assessed using computed tomography and optical coherence tomography
    Coxson, Harvey O.
    Quiney, Brendan
    Sin, Don D.
    Xing, Li
    McWilliams, Annette M.
    Mayo, John R.
    Lam, Stephen
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2008, 177 (11) : 1201 - 1206
  • [3] Optical Coherence Tomography Imaging for the Diagnosis of Airway Tumors In Vivo
    Manley, Christopher
    Hariri, Lida
    Adams, David
    Lanuti, Michael
    Channick, Colleen
    Keyes, Colleen
    Lamb, Carla
    Beamis, John
    Riker, David
    Cho, Josalyn
    Harris, R.
    Luster, Andrew
    Medoff, Benjamin
    Suter, Melissa
    CHEST, 2015, 148 (04)
  • [4] Optical coherence tomography for the identification and quantification of human airway wall layers
    Goorsenberg, Annika W. M.
    d'Hooghe, J. N. S.
    de Bruin, D. M.
    Roelofs, J. J. T. H.
    Annema, J. T.
    Bonta, P. I.
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [5] Optical coherence tomography for human airway wall layer identification and quantification
    d'Hooghe, Julia N. S.
    de Bruin, Daniel M.
    Roelofs, Joris J. T. H.
    Annema, Jouke T.
    Bonta, Peter I.
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [6] Validation of Airway Wall Measurements by Optical Coherence Tomography in Porcine Airways
    Lee, Anthony M. D.
    Kirby, Miranda
    Ohtani, Keishi
    Candido, Tara
    Shalansky, Rebecca
    MacAulay, Calum
    English, John
    Finley, Richard
    Lam, Stephen
    Coxson, Harvey O.
    Lane, Pierre
    PLOS ONE, 2014, 9 (06):
  • [7] Gender Differences in Airway Wall Measurements with Optical Coherence Tomography (OCT)
    Holy, L.
    Storness-Bliss, C.
    Wanono, R.
    Lam, S.
    Sin, D. D.
    McWilliams, A. M.
    Coxson, H. O.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [8] Endobronchial polarization sensitive optical coherence tomography for airway wall imaging
    Vassileva, Sofi
    Wijsman, Pieta C.
    Soldati, Tatiana
    Vaselli, Margherita
    Goorsenberg, Annika W. M.
    De Bruin, Daniel M.
    De Boer, Johannes F.
    Annema, Jouke T.
    Bonta, Peter I.
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [9] Optical coherence tomography for identification and quantification of human airway wall layers
    d'Hooghe, Julia N. S.
    Goorsenberg, Annika W. M.
    de Bruin, Daniel M.
    Roelofs, Joris J. T. H.
    Annema, Jouke T.
    Bonta, Peter I.
    PLOS ONE, 2017, 12 (10):
  • [10] Airway wall responses to tidal breathing and deep inspiration
    Ansell, Thomas K.
    Noble, Peter B.
    Mitchell, Howard W.
    McFawn, Peter
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40