Comparison and validation of UV dose calculations for low- and medium-pressure mercury arc lamps

被引:10
|
作者
Wright, HB [1 ]
机构
[1] Trojan Technol Inc, Dept Res & Dev, London, ON N5V 4T7, Canada
关键词
UV disinfection; germicidal dose; medium pressure; wastewater; collimated beam;
D O I
10.2175/106143000X137978
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A method for calculating UV dose for microbial disinfection that includes a measure of the wavelength-dependent factors of UV lamp output, quartz sleeve UV transmission, microbial action spectra, and wastewater UV transmission is presented. The method is validated by comparing UV dose-response curves for the disinfection of a secondary effluent achieved using collimated beams of UV light generated from low- and medium-pressure mercury arc lamps. The wastewater UV transmittance is artificially altered as part of the validation process. A simplified and practical method of UV dose calculation that relies only on a measure of the UV transmission at 254 nm is proposed for the disinfection of domestic wastewaters by medium-pressure lamps. The proposed method is validated using wastewater samples obtained from 21 wastewater treatment plants located across North America.
引用
收藏
页码:439 / 443
页数:5
相关论文
共 50 条
  • [31] Effects of low- or medium-pressure ultraviolet lamp irradiation on Microcystis aeruginosa and Anabaena variabilis
    Sakai, Hiroshi
    Oguma, Kumiko
    Katayama, Hiroyuki
    Ohgaki, Shinichiro
    WATER RESEARCH, 2007, 41 (01) : 11 - 18
  • [32] A comparison of DNA repair and survival of Escherichia coli O157:H7 following exposure to both low- and medium-pressure UV irradiation
    Zimmer-Thomas, J. L.
    Slawson, R. M.
    Huck, P. M.
    JOURNAL OF WATER AND HEALTH, 2007, 5 (03) : 407 - 415
  • [33] Inactivation and potential repair of Cryptosporidium parvum following low- and medium-pressure ultraviolet irradiation
    Zimmer, JL
    Slawson, RM
    Huck, PM
    WATER RESEARCH, 2003, 37 (14) : 3517 - 3523
  • [34] COMPARISON OF CERTAIN SPECTRAL CHARACTERISTICS OF LOW-PRESSURE MERCURY LAMPS
    TYULIN, VI
    TATEVSKII, VM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1964, (JUN) : 1008 - &
  • [35] Bromate formation from the oxidation of bromide in the UV/chlorine process with low pressure and medium pressure UV lamps
    Fang, Jingyun
    Zhao, Quan
    Fan, Chihhao
    Shang, Chii
    Fu, Yun
    Zhang, Xiangru
    CHEMOSPHERE, 2017, 183 : 582 - 588
  • [36] Comparison of ultraviolet light-emitting diodes and low-pressure mercury-arc lamps for disinfection of water
    Sholtes, Kari A.
    Lowe, Kincaid
    Walters, Glenn W.
    Sobsey, Mark D.
    Linden, Karl G.
    Casanova, Lisa M.
    ENVIRONMENTAL TECHNOLOGY, 2016, 37 (17) : 2183 - 2188
  • [37] Comparative Assessments of At-Sea and Inland Low- and Medium-Pressure CO2 Transport
    Røe, Ingeborg Treu
    Oeuvray, Pauline
    Mazzotti, Marco
    Roussanaly, Simon
    Energies, 2024, 17 (23)
  • [38] Comparison of Low Pressure and Medium Pressure UV Lamps for UV/H2O2 Treatment of Natural Waters Containing Micro Pollutants
    Ijpelaar, Guus F.
    Harmsen, Danny J. H.
    Beerendonk, Erwin F.
    van Leerdam, Robin C.
    Metz, Debbie H.
    Knol, Antonie H.
    Fulmer, Alice
    Krijnen, Simon
    OZONE-SCIENCE & ENGINEERING, 2010, 32 (05) : 329 - 337
  • [39] Radiation Curing of Phosphorus Telomer-Based Coatings Using UV LEDs or Medium-Pressure Mercury Lamp
    Kraskiewicz, Agata
    Kowalczyk, Agnieszka
    MATERIALS, 2023, 16 (23)
  • [40] Effect of medium-pressure and low-pressure UV irradiation on bromate removal in an Advanced Reduction Process (ARP)
    Jung, Bahngmi
    Batchelor, Bill
    Abdel-Wahab, Ahmed
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248