AGIPD - The Adaptive Gain Integrating Pixel Detector for the European XFEL. Development and Status

被引:0
|
作者
Becker, J. [1 ]
Goettlicher, P. [1 ]
Graafsma, H. [1 ]
Hirsemann, H. [1 ]
Jack, S. [1 ]
Klyuev, A. [1 ]
Lange, S. [1 ]
Marras, A. [1 ]
Nilsson, B. [1 ]
Tian, F. [2 ]
Trunk, U. [1 ]
Klanner, R. [3 ]
Schwandt, J. [3 ]
Zhang, J. [3 ]
Dinapoli, R. [4 ]
Greiffenberg, D. [4 ]
Henrich, B. [4 ]
Mozzanica, A. [4 ]
Schmitt, B. [4 ]
Shi, X. [4 ]
Gronewald, M. [5 ]
Karagounis, M. [5 ]
Krueger, H. [5 ]
机构
[1] DESY, Notkestr 85, D-2000 Hamburg, Germany
[2] Infineon Technol, Munich, Germany
[3] Univ Hamburg, Hamburg, Germany
[4] PSI, Villigen, Switzerland
[5] Univ Bonn, Bonn, Germany
关键词
XFEL; 2D detector; Hybrid Pixel Detector;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The European XFEL [1] will provide fully coherent, 100 fs X-ray pulses, with up to 10(12) photons at 12keV. The high intensity per pulse will allow recording diffraction patterns of single particles or small crystals in a single shot. Consequently 2D-detectors have to cope with a large dynamic range: detection from single photon to >10(4) photons/pixel in the same image. An additional challenge is the European XFEL machine: an Electron bunch train with 10 Hz repetition rate, consisting of up to 2,700 bunches with a 220 ns spacing. Recorded images have to be stored inside the pixel during the bunch trains and readout in between. To meet these requirements, the European XFEL has launched 3 detector development projects. The AGIPD project is a collaboration between DESY, PSI and the Universities of Bonn and Hamburg. The goal is a 1024 x 1024 pixel detector, with 200 mu m pixel size and a central hole for the primary beam. The ASIC operates in charge integration mode: the output of each pixels preamplifier is proportional to the charge from the sensor generated by the Xrays. The input stage of the pixel cells uses dynamically adjustable gains. The output signal is stored in an analogue memory, which has to be a compromise between noise performance and the number of images. This is operated in random access mode, providing means to overwrite bad frames for optimal use of the 352 memory cells per pixel, which have to be readout and digitized in the 99.4 ms bunch gap. The detector will be built of 8 x 2 fully depleted monolithic silicon sensors with a 8 x 2 array of CMOS readout chips bump-bonded to these. Several prototypes of the readout ASIC have been produced. The results presented originate from the 16 x 16 pixel matrices AGIPD 0.2, which was bump-bonded to a pixel sensor, and AGIPD 0.3, which includes the intended control algorithm and a fast differential interface to the off-chip world.
引用
收藏
页码:1950 / 1954
页数:5
相关论文
共 31 条
  • [21] Status of the laboratory infrastructure for detector calibration and characterization at the European XFEL
    Raab, N.
    Ballak, K. -E.
    Dietze, T.
    Ekmedzic, M.
    Hauf, S.
    Januschek, F.
    Kaukher, A.
    Kuster, M.
    Lang, P. M.
    Muennich, A.
    Schmitt, R.
    Sztuk-Dambietz, J.
    Turcato, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [22] Status of LLRF system development for European XFEL
    Koprek, W.
    Grecki, M.
    Makowski, D.
    Pawlik, P.
    Weddig, H.
    Lorbeer, B.
    Hoffmann, M.
    Mukherjee, B.
    Czuba, K.
    Koseda, B.
    Cichalewski, W.
    Pozniak, K. T.
    Romaniuk, R. S.
    Simrock, S.
    [J]. PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2006, PTS 1 AND 2, 2006, 6347
  • [23] Strategy for Calibrating the Non-Linear Gain of the DSSC Detector for the European XFEL
    Weidenspointner, G.
    Andritschke, R.
    Aschauer, S.
    Fischer, P.
    Granato, S.
    Hansen, K.
    Lechner, P.
    Lutz, G.
    Moch, D.
    Porro, M.
    Sandow, C.
    Sant, T.
    Strueder, L.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 468 - 473
  • [24] Calibration status and plans for the charge integrating JUNGFRAU pixel detector for SwissFEL
    Redford, S.
    Bergamaschi, A.
    Bruckner, M.
    Cartier, S.
    Dinapoli, R.
    Ekinci, Y.
    Frojdh, E.
    Greiffenberg, D.
    Mayilyan, D.
    Mezza, D.
    Mozzanica, A.
    Rajeev, R.
    Ramilli, M.
    Ruder, C.
    Schadler, L.
    Schmitt, B.
    Shi, X.
    Thattil, D.
    Tinti, G.
    Zhang, J.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [25] Study of Systematic and Statistical Uncertainty in Offset, Noise, and Gain Determination of the DSSC Detector for the European XFEL
    Weidenspointner, Georg
    Schlee, Stephan
    Castoldi, Andrea
    Guazzoni, Chiara
    Maffessanti, Stefano
    Porro, Matteo
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [26] The 2D X-ray detector development program for the European XFEL
    Schwarz, Andreas S.
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C162 - C162
  • [27] Methods for calibrating the gain and offset of the DSSC detector for the European XFEL using X-ray line sources
    Schlee, S.
    Weidenspointner, G.
    Moch, D.
    Kuster, M.
    Porro, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [28] Status of the laboratory infrastructure for detector calibration and characterization at the European XFEL (vol 11, C12051, 2016)
    Raab, N.
    Ballak, K. -E.
    Dietze, T.
    Ekmedzic, M.
    Hauf, S.
    Januschek, F.
    Kaukher, A.
    Kuster, M.
    Lang, P. M.
    Muennich, A.
    Schmitt, R.
    Sztuk-Dambietz, J.
    Turcato, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [29] Status and overview of development of the silicon pixel detector for the PHENIX experiment at the BNL RHIC
    Ichimiya, R.
    Apadula, N.
    Akiba, Y.
    Atomssa, E.
    Chollet, S.
    Drapier, O.
    En'yo, H.
    Fujiwara, K.
    Gastaldi, F.
    de Cassagnac, R. Granier
    Kasai, M.
    Kurita, K.
    Kurosawa, M.
    Mannel, E. J.
    Ohnishi, H.
    Onuki, Y.
    Pak, R.
    Pancake, C.
    Sekimoto, M.
    Shafto, E.
    Sondheim, W.
    Taketani, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2009, 4
  • [30] The present status of pixel detector development for high energy physics collider applications
    Hallewell, GD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01): : 44 - 54