Optimization and safety of the intra-aortic balloon pumping balloon catheter

被引:3
|
作者
Tsutsui, Nobumasa [1 ]
Tsutsui, Yoko [1 ]
Tsutsui, Yasuhiro [1 ]
Hashimoto, Kazuaki [1 ]
Miwa, Kyoko [1 ]
Kato, Kazuhide [1 ]
机构
[1] Tokai Med Prod Inc, Kasugai, Aichi 4860808, Japan
关键词
IABP; balloon; optimization; safety;
D O I
10.1007/s10047-007-0385-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tokai Medical Products developed an intra-aortic balloon pumping (IABP) balloon catheter with the following unique characteristics: the balloon can be applied to any patient irrespective of their physical size, and is therefore suitable for Japanese patients of small stature; a long soft tip is used, which is designed to avoid damage to blood vessels; the size of the catheter is reduced to 7Fr, and the catheter can be used as a multifunctional balloon catheter, such as the Yoshioka type, that allows simultaneous percutaneous coronary intervention (PCI). The safety of this catheter has been proven in scientific studies. In this review, we report the development of our IABP balloon catheter and give an outline of its characteristics.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 50 条
  • [31] Minimal invasive intra-aortic pumping with the Glidesheath Slender and a 6-French intra-aortic balloon catheter
    Yamada, T.
    Takahashi, A.
    Hashimoto, S.
    Mizuguchi, Y.
    Taniguchi, N.
    Nakajima, S.
    Hata, T.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 281 - 282
  • [32] UMBRELLA BALLOON FOR MAXIMUM UNLOADING DURING INTRA-AORTIC BALLOON PUMPING
    ANSTADT, GL
    SCHIFF, P
    [J]. TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1981, 27 : 461 - 466
  • [33] INTRA-AORTIC BALLOON PUMPING IN WOMEN - EFFECTS OF BALLOON SIZE ON SURVIVAL
    BEDDERMANN, C
    MCGEE, MG
    TURNER, SA
    DAVIS, GL
    DENNING, JV
    NORMAN, JC
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1980, 28 (06): : 428 - 432
  • [34] Change in design of intra-aortic balloon catheter
    Higgins, D.
    Kan, M.
    [J]. ANAESTHESIA, 2007, 62 (03) : 297 - 298
  • [35] INTRA-AORTIC BALLOON PUMPING IN THE ELDERLY - PERCUTANEOUS VERSUS SURGICAL CATHETER INSERTION
    DIBARI, M
    DEALFIERI, W
    GREPPI, B
    CONTI, A
    FERRUCCI, L
    CALAMANDREI, M
    VANNUCCI, A
    PINI, R
    MENEGATTI, G
    VASSANELLI, C
    MARCHIONNI, N
    [J]. EUROPEAN HEART JOURNAL, 1984, 5 (03) : 222 - 226
  • [36] SAFETY OF INTRA-AORTIC BALLOON PUMPING .1. BIOCHEMIC AND HEMATOLOGIC VALUES INFLUENCED BY USE OF BALLOON
    SCHNEIDER, MD
    KAYE, MP
    BLATT, SJ
    TOBIN, HG
    ECKNER, FAO
    [J]. THROMBOSIS RESEARCH, 1974, 4 (03) : 387 - 397
  • [37] Compact and Light Intra-Aortic Balloon Pumping System
    [J]. Physical Review B: Condensed Matter, 1995, 516
  • [38] MORPHOLOGIC RESULTS OF INTRA-AORTIC BALLOON PUMPING IN MAN
    KATUBIG, C
    REID, JD
    KENNEDY, JH
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1970, 11 (04): : 274 - &
  • [39] CLINICAL-EXPERIENCE WITH INTRA-AORTIC BALLOON PUMPING
    MOCCETTI, T
    RIVA, A
    CLARA, F
    TARTINI, R
    NAEGELI, U
    MOLO, C
    RONDI, L
    [J]. SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 112 (37) : 1286 - 1289
  • [40] COMPREHENSIVE INTRA-AORTIC BALLOON PUMPING - QUAAL,SJ
    BLISS, SW