Measurement properties of the Motor Evaluation Scale for Upper Extremity in Stroke patients (MESUPES)

被引:21
|
作者
Johansson, Gudrun M. [1 ]
Hager, Charlotte K. [1 ]
机构
[1] Umea Univ, Dept Community Med & Rehabil, SE-90187 Umea, Sweden
关键词
arm; motor evaluation scale for upper extremity in stroke patients MESUPES; movement; stroke; MINIMAL DETECTABLE CHANGE; BERG BALANCE SCALE; INTERRATER RELIABILITY; HEMIPARESIS; REHABILITATION; MOVEMENT; TESTS; REPRODUCIBILITY; QUALITY; PEOPLE;
D O I
10.3109/09638288.2011.606343
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: To investigate inter-rater reliability of the Motor Evaluation Scale for Upper Extremity in Stroke patients (MESUPES), to provide estimates of the minimal detectable change (MDC) of the MESUPES and to investigate concurrent validity in relation to the arm scores of the Modified Motor Assessment Scale (M MAS). Methods: Forty-two stroke patients (mean age 56 +/- 12 years) were independently assessed within a 48-hours window by two raters in different pairs (total available raters = 4). Results: Weighted. analysis indicated good to very good agreement at item level (range 0.63-0.96). The relative and absolute reliability of the total score of MESUPES (maximum 58) was high according to the intraclass correlation coefficients (ICC = 0.98) and the standard error of measurement (SEM = 2.68). The MDC for three levels of confidence was calculated: A score change of 8, 7 and 5 is necessary for a MDC to have confidence of 95%, 90% and 80%, respectively, of a genuine change. Correlation between the MESUPES and M MAS was high (r(s) = 0.87). Conclusions: The MESUPES shows high inter-rater reliability, and our study provides useful estimates of MDC for different levels of certainty. Additional research to confirm concurrent validity and to examine other psychometric properties of the MESUPES such as sensitivity is needed.
引用
收藏
页码:288 / 294
页数:7
相关论文
共 50 条
  • [21] RECOVERY OF IMPAIRED MOTOR FUNCTION OF THE UPPER EXTREMITY AFTER STROKE
    NAKAMURA, R
    MORIYAMA, S
    YAMADA, Y
    SEKI, K
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1992, 168 (01): : 11 - 20
  • [22] Kinematic Evaluation via Inertial Measurement Unit Associated with Upper Extremity Motor Function in Subacute Stroke: A Cross-Sectional Study
    Chen, Ze-Jian
    He, Chang
    Gu, Ming-Hui
    Xu, Jiang
    Huang, Xiao-Lin
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021
  • [23] Kinematic Evaluation via Inertial Measurement Unit Associated with Upper Extremity Motor Function in Subacute Stroke: A Cross-Sectional Study
    Chen, Ze-Jian
    He, Chang
    Gu, Ming-Hui
    Xu, Jiang
    Huang, Xiao-Lin
    Journal of Healthcare Engineering, 2021, 2021
  • [24] REHABILITATION OF THE UPPER EXTREMITY IN CHRONIC STROKE PATIENTS
    HAMMOND, MC
    KRAFT, GH
    FITTS, SS
    NUTTER, PB
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1987, 68 (09): : 631 - 631
  • [25] Orthopaedic management of the upper extremity of stroke patients
    Tafti, Mona A.
    Cramer, Steven C.
    Gupta, Ranjan
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (08) : 462 - 470
  • [26] Proximal paresis of the upper extremity in patients with stroke
    Hatakenaka, Megumi
    Miyai, Ichiro
    Sakoda, Saburo
    Yanagihara, Takehiko
    NEUROLOGY, 2007, 69 (04) : 348 - 355
  • [27] Validity and reliability of selective control of upper extremity scale (SCUES) in patients with chronic stroke
    Sonmez, Didem Boz
    Giray, Esra
    Atici, Arzu
    Illeez, Ozge Gulsum
    Akpinar, Pinar
    Ozkan, Feyza Unlu
    Aktas, Ilknur
    DISABILITY AND REHABILITATION, 2024, 46 (20) : 4813 - 4824
  • [28] Evaluation of upper extremity motor function tests in tetraplegics
    van Tuijl, JH
    Janssen-Potten, YJM
    Seelen, HAM
    SPINAL CORD, 2002, 40 (02) : 51 - 64
  • [29] Evaluation of upper extremity motor function tests in tetraplegics
    JH van Tuijl
    YJM Janssen-Potten
    HAM Seelen
    Spinal Cord, 2002, 40 : 51 - 64
  • [30] An upper extremity kinematic model for evaluation of hemiparetic stroke
    Hingtgen, B
    McGuire, JR
    Wang, M
    Harris, GF
    JOURNAL OF BIOMECHANICS, 2006, 39 (04) : 681 - 688