EFFECT OF FENTON PROCESS (H2O2 / Fe2+) ON REMOVAL OF LINEAR ALKYLBENZENE SULFONATE USING CENTRAL COMPOSITE
被引:0
|
作者:
Mousavi, S. A. R.
论文数: 0引用数: 0
h-index: 0
机构:
Kermanshah Univ Med Sci, Deputy Hlth Serv, Dept Environm Hlth, Kermanshah, Iran
Univ Malaya, Dept Civil & Environm Engn, Kuala Lumpur, MalaysiaUniv Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
Mousavi, S. A. R.
[3
,5
]
论文数: 引用数:
h-index:
机构:
Mahvi, A. H.
[1
,2
,4
]
Nasseri, S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
Univ Tehran Med Sci, Environm Res Ctr, Tehran, IranUniv Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
Nasseri, S.
[1
,2
]
Ghafari, Sh
论文数: 0引用数: 0
h-index: 0
机构:
Univ Malaya, Dept Civil & Environm Engn, Kuala Lumpur, MalaysiaUniv Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
Ghafari, Sh
[5
]
机构:
[1] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Environm Res Ctr, Tehran, Iran
This study investigates the degradation of Linear Alkylbenzene Sulfonate (LAS) in aqueous solution using Fenton's process in a batch reactor (at pH = 3 and 25 degrees C). Experiments were carried out to survey the effects of the amounts of ferrous sulfate (FeSO4 center dot 7H(2)O) and hydrogen peroxide (H2O2) on the LAS and COD removal. Central composite design and response surface methods were used to optimize the Fenton oxidation process through examination of three independent operating variables namely oxidant dose (H2O2), catalyst dose (Fe+2) and reaction time., hydrogen peroxide dose ranging from 150 to 750 mg /L and Fe+2 concentration in the range of 10-130 mg /L were selected to be examined at different reaction times between 20 and 80 minutes. Models were developed and results shows that the oxidation capacities of H2O2 /Fe+2 were highly dependent on the concentration of H2O2 and Fe+2. Satisfactory decay rates of LAS to lock up biodegradable concentration level were obtained, and in the case for oxidation of 200 mg /L LAS, the optimum values were achieved at 600 and 130 mg/L for H2O2 and Fe+2, respectively.
机构:
Slovak Univ Technol Bratislava, Fac Chem Technol, Dept Environm Sci, Bratislava 81237, SlovakiaSlovak Univ Technol Bratislava, Fac Chem Technol, Dept Environm Sci, Bratislava 81237, Slovakia
Prousek, J
Dömötörová, J
论文数: 0引用数: 0
h-index: 0
机构:
Slovak Univ Technol Bratislava, Fac Chem Technol, Dept Environm Sci, Bratislava 81237, SlovakiaSlovak Univ Technol Bratislava, Fac Chem Technol, Dept Environm Sci, Bratislava 81237, Slovakia