Tests of Reference Samples for Calibration of Hydrogen Analyzers

被引:0
|
作者
Polyanskiy, V. A. [1 ]
Belyaev, A. K. [1 ]
Yakovlev, Yu. A. [1 ]
Polyanskiy, A. M. [2 ]
机构
[1] Russian Acad Sci, Inst Problems Mech Engn, 61 VO Bolshoy Ave, St Petersburg 199178, Russia
[2] RDC Electron & Beam Technol Ltd, 6 Bronevaya St, St Petersburg 198188, Russia
关键词
DIFFUSION; VACUUM;
D O I
10.1063/1.5135117
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Low hydrogen concentration, of the order of ppm, reduces the strength and toughness of steels and other alloys by several times. These concentrations are measured using hydrogen analyzers during manufacturing and operation of metal products. Unlike other chemical elements, the mandatory regular international comparisons are not carried out on measurements of hydrogen concentration. The article presents test data for reference samples of hydrogen concentration obtained in various laboratories. It is concluded that it is necessary to build a metrological system for measuring hydrogen concentration by using physically substantiated analysis methods.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] CALIBRATION OF RAPID GAS ANALYZERS WITH A MIXING CHAMBER
    YOUNG, AC
    BRANDT, G
    BRAND, EH
    MARTIN, CJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (01) : 112 - &
  • [42] Remote calibration system for automatic circuit analyzers
    Gusinskiy, A. V.
    Deryabina, M. Yu.
    Gusynina, Yu. A.
    Kostrikin, A. M.
    Tolochko, T. K.
    2006 16TH INTERNATIONAL CRIMEAN CONFERENCE MICROWAVE & TELECOMMUNICATION TECHNOLOGY, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2006, : 807 - +
  • [43] LRR - A self-calibration technique for the calibration of vector network analyzers
    Rolfes, I
    Schiek, B
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 316 - 319
  • [44] CALIBRATION OF TIME-DOMAIN NETWORK ANALYZERS
    SU, WS
    RIAD, SM
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (02) : 157 - 161
  • [45] PARTIAL PRESSURE CALIBRATION FOR RESIDUAL GAS ANALYZERS
    MORRISON, CF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1969, 6 (01): : 79 - &
  • [46] CALCULATION OF CALIBRATION CHARACTERISTICS OF LASER MICROPARTICLE ANALYZERS
    OVOD, VI
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1987, 54 (04): : 199 - 202
  • [47] PARTIAL PRESSURE CALIBRATION FOR RESIDUAL GAS ANALYZERS
    MORRISON, CF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1968, 5 (05): : 173 - &
  • [48] CHECKING AND CALIBRATION OF GAS ANALYZERS FOR PAIRS OF LIQUIDS
    MGALOBLI.KD
    MEASUREMENT TECHNIQUES-USSR, 1971, 14 (02): : 328 - &
  • [49] CALIBRATION OF MULTIANGULAR MAGNETIC ANALYZERS-MULTISPECTROGRAPHS
    LITVIN, VF
    ZHEREBTSOVA, KI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1964, (JUN) : 1029 - &
  • [50] CALIBRATION OF CARBONIC-ACID GAS ANALYZERS
    VOZNESENSKY, VL
    SHCHERBATYUK, AS
    FIZIOLOGIYA I BIOKHIMIYA KULTURNYKH RASTENII, 1982, 14 (06): : 600 - 606