Theory and Experimental Validation of Two Techniques for Compensating VT Nonlinearities

被引:8
|
作者
D'Avanzo, Giovanni [1 ,2 ]
Faifer, Marco [3 ]
Landi, Carmine [2 ]
Laurano, Christian [3 ]
Letizia, Palma Sara [4 ,5 ]
Luiso, Mario [2 ]
Ottoboni, Roberto [3 ]
Toscani, Sergio [3 ]
机构
[1] Ric Sistema Energet SpA, I-20134 Milan, Italy
[2] Univ Campania, Dipartimento Ingn, I-81031 Aversa, Italy
[3] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[4] Politecn Torino, I-10129 Turin, Italy
[5] Ist Nazl Ric Metrol, I-10135 Turin, Italy
关键词
Harmonic analysis; Voltage measurement; Distortion measurement; Power harmonic filters; Current measurement; Harmonic distortion; Power measurement; Compensation; harmonic distortion (HD); harmonics; harmonics measurement; instrument transformer (IT); nonlinearity; power quality (PQ); power system measurements; voltage transformer (VT); VOLTAGE TRANSFORMERS; HARMONIC-ANALYSIS; ACCURACY;
D O I
10.1109/TIM.2022.3147883
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Inductive instrument transformers (ITs) are still the most used voltage and current sensors in power systems. Among the numerous applications that require their use, one of the most important is surely represented by harmonics measurement. In this case, the recent literature shows that, since they suffer from both a filtering behavior due to their dynamics and from nonlinear effects produced by their iron core, they can introduce errors up to some percent. This article wants to deeply investigate, in the very same experimental conditions, about the performance of two digital signal processing techniques, recently introduced for the improvement of harmonics measurements performed through ITs, namely, SINusoidal characterization for DIstortion COMPensation (SINDICOMP) and compensation of harmonic distortion through polynomial modeling in the frequency domain (PHD). These methods have been applied to two different voltage transformers, having different specifications, by using two measurement setups based on different architectures. The impact of the voltage generator employed during the identification on the achieved accuracy is theoretically and experimentally evaluated. Modified versions of SINDICOMP and PHD compensation, which are more robust against nonidealities of the measurement setup, are presented. The performances of the techniques are evaluated by adopting voltage waveforms similar to those that can be encountered during the normal operation in a real distribution grid.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Dielectrowetting actuation of droplet: Theory and experimental validation*
    Huang, Yayan
    Zhao, Rui
    Liang, Zhongcheng
    Zhang, Yue
    Kong, Meimei
    Chen, Tao
    CHINESE PHYSICS B, 2021, 30 (10)
  • [22] Dielectrowetting actuation of droplet: Theory and experimental validation
    黄亚俨
    赵瑞
    梁忠诚
    张月
    孔梅梅
    陈陶
    Chinese Physics B, 2021, (10) : 457 - 462
  • [23] New experimental techniques for validation of marine discharge models
    Roberts, PJW
    Tian, XD
    ENVIRONMENTAL MODELLING & SOFTWARE, 2004, 19 (7-8) : 691 - 699
  • [24] Experimental validation of the theory of wall effect on dielectrophoresis
    Lo, Y. J.
    Lei, U.
    APPLIED PHYSICS LETTERS, 2010, 97 (09)
  • [25] Isotachophoresis at pH extremes: Theory and experimental validation
    Ermakov, SV
    Zhukov, MY
    Capelli, L
    Righetti, PG
    ELECTROPHORESIS, 1998, 19 (02) : 192 - 205
  • [26] Dimensioning of thickeners: experimental validation of three conventional techniques
    de Souza Pinto, Thiago Cesar
    Baptista de Lima, Jose Renato
    de Moraes Junior, Deovaldo
    Leal Filho, Laurindo de Salles
    REM-REVISTA ESCOLA DE MINAS, 2009, 62 (02) : 243 - 249
  • [27] Experimental Validation of Inversion Techniques for an LPV motion system
    Kasemsinsup, Yanin
    Ardyanto, Aditya Ferry
    Butler, Hans
    Heertjes, Marcel
    Weiland, Siep
    2018 ANNUAL AMERICAN CONTROL CONFERENCE (ACC), 2018, : 6690 - 6696
  • [28] Novel techniques for compensating negative sequence voltage using instantaneous active reactive power theory
    Electrical Research and Development Association, Makarpura GIDC, Vadodara, Gujarat, India
    不详
    J Inst Eng India: Electr Eng Div, 2008, DECEMBER (31-36):
  • [29] Experimental validation of a plier with two retractable fingers
    Soriano-Heras, Enrique
    Rubio-Alonso, Higinio
    Carlos Garcia-Prada, Juan
    Carbone, Giuseppe
    DYNA, 2016, 91 (01): : 34 - 41
  • [30] An Experimental Case Study for Nonlinear Model Validation: Effect of Nonlinearities in an Aero-Engine Structure
    Cooper, Samson B.
    DiMaio, Dario
    Sever, Ibrahim A.
    Patsias, Sophoclis
    MODEL VALIDATION AND UNCERTAINTY QUANTIFICATION, VOL 3, 2019, : 37 - 47