Rupture of abdominal aortic aneurysm (AAA) ranks as the 13th leading cause of death in the US. Fluid Structure Interaction (FSI) analysis was conducted with the aim of strengthening the current diagnostic measures of the disease, in particular, to (i) predict the location of wall rupture, (ii) estimate the state of pathology from the calculated ruptured potential index (RPI) and (iii) predict the disease progression by comparing healthy and pathological aortas (non-ruptured and ruptured AAAs). FSI simulations were carried out on three dimensional patient specific geometries reconstructed from CT data. The arterial wall in the reconstructed geometries was modeled as anisotropic material. Other critical characteristics of AAA such as intraluminal thrombus (ILT) and embedded calcifications (Ca) were incorporated in the patient-specific models. Results obtained from the FSI simulations indicate an increase in wall shear stress with progression of the disease. ILT is found to reduce the wall stress while calcium deposition on walls increases the local wall stress. Using rupture potential index (RPI), the location of rupture is successfully predicted.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] The effect of angulation in abdominal aortic aneurysms: fluid-structure interaction simulations of idealized geometries
    Xenos, Michalis
    Alemu, Yared
    Zamfir, Dan
    Einav, Shmuel
    Ricotta, John J.
    Labropoulos, Nicos
    Tassiopoulos, Apostolos
    Bluestein, Danny
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (12) : 1175 - 1190
  • [32] EFFECTS OF TURBURLENT BLOOD FLOW ON ABDOMINAL AORTIC ANEURYSMS: A FLUID-STRUCTURE INTERACTION STUDY
    Lin, Shengmao
    Gu, Linxia
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3A, 2014,
  • [33] Application of Fluid–Structure Interaction Methods to Estimate the Mechanics of Rupture in Asian Abdominal Aortic Aneurysms
    Canchi T.
    Saxena A.
    Ng E.
    Pwee E.C.
    Narayanan S.
    Ng, Eyk (mykng@ntu.edu.sg), 2018, Springer Science and Business Media, LLC (08) : 1035 - 1044
  • [34] Fluid structure interaction study in model abdominal aortic aneurysms: Influence of shape and wall motion
    Philip, Nimmy Thankom
    Patnaik, B. S. V.
    B. J., Sudhir
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (03)
  • [35] Fluid-Structure Interaction of Pre- and Post-operative Abdominal Aortic Aneurysms
    Molony, D. S.
    Walsh, M. T.
    McGloughlin, T. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1018 - 1021
  • [36] Fluid–structure interaction simulations of patient-specific aortic dissection
    Kathrin Bäumler
    Vijay Vedula
    Anna M. Sailer
    Jongmin Seo
    Peter Chiu
    Gabriel Mistelbauer
    Frandics P. Chan
    Michael P. Fischbein
    Alison L. Marsden
    Dominik Fleischmann
    Biomechanics and Modeling in Mechanobiology, 2020, 19 : 1607 - 1628
  • [37] ASSESSMENT OF ABDOMINAL AORTIC ANEURYSMS
    WESTON, TS
    ARDAGH, JW
    NEW ZEALAND MEDICAL JOURNAL, 1973, 77 (492) : 305 - 307
  • [38] Fluid-structure interaction simulation for studying hemodynamics and rupture risk of patient-specific intracranial aneurysms
    Ruan, Chang
    Yu, Qi
    Hou, Jingyuan
    Ou, Xinying
    Liu, Yi
    Chen, Yu
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2023, 25 (03) : 73 - 85
  • [39] Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft
    Molony, David S.
    Callanan, Anthony
    Kavanagh, Eamon G.
    Walsh, Michael T.
    McGloughlin, Tim M.
    BIOMEDICAL ENGINEERING ONLINE, 2009, 8 : 24
  • [40] Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft
    David S Molony
    Anthony Callanan
    Eamon G Kavanagh
    Michael T Walsh
    Tim M McGloughlin
    BioMedical Engineering OnLine, 8